ANGIOGRAPHIC CATHETERS Common Angiographic Catheter Shapes for Vessel Selection Cerebral Region
Transcription
ANGIOGRAPHIC CATHETERS Common Angiographic Catheter Shapes for Vessel Selection Cerebral Region
ANGIOGRAPHIC CATHETERS A Comprehensive Offering to Meet Your Peripheral Angiography Needs Common Angiographic Catheter Shapes for Vessel Selection Visceral Region Cerebral Region Descending Aorta 1. Omni™ Flush 2. Pigtail Flush 3. Straight Flush L and R Subclavian Artery and Vein 1. Berenstein 2. Weinberg 3. Head Hunter 1 Ascending Aorta 1. Omni™ Flush 2. Pigtail Flush L and R Vertebral Artery and Vein 1. Berenstein 2. Weinberg 3. Head Hunter 1 4. Vertebral Thoracic Aorta 1. Omni™ Flush 2. Pigtail Flush 3. Straight Flush L and R Common Carotid Artery 1. Head Hunter 1 2. Sidewinder 1 3. Weinberg 4. Berenstein 5. Vertebral 6. Head Hunter 3 Abdominal Aorta 1. Omni™ Flush 2. Pigtail Flush Hepatic Artery and Vein 1. Cobra 1, 2, or 3 2. Berenstein 3. Sos Omni® 2 4. MPA Brachiocephalic Artery 1. Head Hunter 1 2. Sidewinder 1 3. Weinberg 4. Berenstein Splenic Artery and Vein 1. Cobra 1, 2, or 3 2. Berenstein 3. Sos Omni® 0 4. Sidewinder 1, 2, or 3 L and R External Carotid Artery 1. Head Hunter 1 2. Sidewinder 1 3. Hockey Stick 1 4. Weinberg 5. Berenstein 6. Sidewinder 2 Gastric Artery and Vein 1. Cobra 1 2. Cobra 2 3. Sidewinder 2 4. Sos Omni® 2 5. RC1 L and R Internal Carotid Artery 1. Head Hunter 1 2. Sidewinder 1 3. Weinberg 4. Berenstein 5. Head Hunter 3 Gastroduodenal Artery and Vein 1. Cobra 2 2. Sos Omni® 0 3. Berenstein 4. Sidewinder 1 L and R Brachiocephalic Vein 1. Head Hunter 1 2. Sidewinder 1 3. Berenstein Pancreatic Artery and Vein 1. Cobra 2 2. Sos Omni® 0 3. Berenstein 4. Sidewinder 1 L and R Internal Jugular Vein 1. Head Hunter 1 2. Sidewinder 1 3. Sidewinder 2 4. Sidewinder 3 5. Berenstein 6. Shepherd Hook 2 L and R Renal Artery 1. Sos Omni® 1 2. Sos Omni® 2 3. Cobra 1 4. MPA L and R External Jugular Vein 1. Head Hunter 1 2. Sidewinder 1 3. Sidewinder 2 4. Sidewinder 3 5. Berenstein Celiac Artery and Vein 1. Cobra 1 2. Berenstein 3. Sos Omni® 0 4. JB 1 Superior Mesenteric Artery and Vein 1. Cobra 1, 2, or 3 2. Berenstein 3. Sos Omni® 0 4. Sidewinder 1, 2, or 3 Inferior and Superior Vena Cava 1. Pigtail Sizing 2. Omni™ Flush 3. Rim Uterine Artery 1. Cobra 1, 2, or 3 2. Sos Omni® 0 3. Berenstein Peripheral Region L and R Common Iliac Artery and Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Cobra 1 4. Berenstein L and R Internal Iliac Artery and Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Cobra 1 4. Berenstein L and R External Iliac Artery and Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Berenstein L and R Common Femoral Artery and Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Cobra 1 4. Berenstein 5. MPA L and R Deep Femoral Artery and Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Berenstein L and R Great Saphenous Vein 1. Sos Omni® 1 2. Sos Omni® 2 3. Berenstein L and R Popliteal Artery and Vein 1. Berenstein 2. Straight Art L and R Anterior Tibial Artery and Vein 1. Berenstein 2. Straight Art L and R Posterior Tibial Artery and Vein 1. Berenstein 2. Straight Art L and R Peroneal Artery and Vein 1. Berenstein 2. Straight Art www.angiodynamics.com IMPORTANT RISK INFORMATION INDICATION FOR USE: AngioDynamics Angiographic Catheters are designed for use where angiographic diagnosis is product damage is visible. AngioDynamics Angiographic Catheters should be used only by physicians with a thorough POTENTIAL COMPLICATIONS: The following adverse reactions have been reported and are associated with the use of indicated. CAUTION: Federal (USA) law restricts these devices to sale by or on the order of a physician. understanding of angiography and percutaneous interventional procedures. AngioDynamics 3 French Angiographic angiographic catheters: Thrombus formation, emboli, arterial wall damage, plaque dislodgment, hematoma, cardiac CONTRAINDICATIONS: Angiographic Catheters should not be used for any purpose other than those indicated in Catheters are not intended for intracranial use. Do not insert catheters directly through synthetic vascular grafts. Insert arrhythmias, myocardial infarction, stroke, and death. the instructions. through a sheath introducer. AngioDynamics Angiographic Catheters are designed for use with specific guidewire WARNINGS AND PRECAUTIONS: This device is sterilized by ethylene oxide and is intended for single patient use only. diameters. The recommended maximum guidewire diameter is specified on the catheter label. Optimal guidewire size Do not reuse or resterilize. Contents sterile in unopened, undamaged package. Do not use if opened or any sign of AngioDynamics, Soft-Vu, Accu-Vu and SOS Omni are registered trademarks of AngioDynamics. Mariner, AngiOptic and Omni are trademarks of AngioDynamics. U.S Patents: 5,584,821 © 2012 AngioDynamics, Inc. All rights reserved. MLC 219 US Rev B 12/11 and judicious use are recommended. Please see package insert for complete list of warnings and precautions.