SwitchedDim - HPIDD Stand alone dimming ballasts for HID lamps
Transcription
SwitchedDim - HPIDD Stand alone dimming ballasts for HID lamps
HID Outdoor SwitchedDim - HPIDD Designed and manufactured in the UK HID Outdoor Stand alone dimming ballasts for HID lamps The SwitchedDim range of ballasts are a stand alone HID ballast designed for street, road lighting and indoor applications. It is used in conjunction with an external switching device such as a time clock switch, motion sensor or switched wire. Switched Supply Operation - The ballast switches on at full power and dims to a predetermined level when the switched supply is absent, The ballast will then quickly return to full 100% output when switched supply is present. Reduced Energy Consumption - A standard SwitchedDim ballast saves 30% of power when dimmed. Presence Detection - The lamp will quickly return to 100% when motion is detected. 70% Power IWASAKI Lamp compatability CMH / CDM / HCI / SON/ SDW-T / ColorArc 100% •Standard SwitchedDim ballast •Microprocessor controlled dims to 70% power (55% •Accepts 0.752 to 2.5mm2 solid lumens) in standby mode* and stranded wire •Fast start •Available in 120V (on request) •Compact and lightwieght * Other dimming ranges available. Ask sales •Remote operation up to 25m for more info. Technical Specification Part Number HPIDD60 -240-B/C-CC-SD HPIDD90 -240-B/C-CC-SD HPIDD140 -240-B/C-CC-SD HPIDD70 -240-B/C-CC-SD HPIDD100 -240-B/C-CC-SD HPIDD150 -240-B/C-CC-SD Power Rating 60W (42W when 90W (63W when dimmed) dimmed) 140W (98W when dimmed) 70W (49W when dimmed) 100W (70W when dimmed) 150W (105W when dimmed) Cosmopolis Lamp type 144 CMH, CDM, HCI, SON, SDW-T, ColorArc Mains frequency range AC45-65Hz Power factor Integral ‘B’ version >0.95 Ignition voltage 2.5kV Pk 130 135 Nominal lamp operating frequency 412Hz 160Hz 25m** Lamp current waveform Square Wave 91 36.7 Max. Distance from lamp Max. ambient temperature Ta 50°C Max. case temperature Tc 80°C 171.4 Remote ‘C’ version -20°C to +50°C 415g Weight Max. number of ballasts per Type C/D 16A circuit breaker 28 28 19 28 28 19 171.4 Safety Standard Compliance EN61347-2-12:2005 EN61000-3-2:2000 EN61000-3-3:2001 EN61547:2000 **Harvard HID ballasts employ a unique lamp striking method which allows the lamps to be mounted further away from the ballast than with conventional gear or any other type of electronic ballast. If you ensure the cable capacitance is within the limit specified, you will be able to achieve reliable starting at extended distances. The cable must be 2 core and earthing to the lamp head/luminaire should be routed separately to the lamp wires. Consult factory for approved cable specification www.HarvardEng.com Harvard Engineering plc Tyler Close Data Sheet No.HIDO4 V1 RB Normanton Wakefield Fax: +44 (0)113 383 1010 WF6 1RL UK 91.2 Temperature range Tel: +44 (0)113 383 1000 78 200-265V AC 73 AC voltage range limit