Wigan Community Fire and Ambulance Station PDF 125 KB
Transcription
Wigan Community Fire and Ambulance Station PDF 125 KB
GREATER MANCHESTER FIRE AND RESCUE AUTHORITY 23 APRIL 2015 Subject: WIGAN COMMUNITY FIRE AND AMBULANCE STATION Report of the County Fire Officer & Chief Executive Report Author: Geoff Harris, Director of Prevention & Protection Tel:0161 608 4004 Email: [email protected] PURPOSE OF THE REPORT The purpose of this report is to inform Members of progress towards designing and building a joint Fire and Ambulance Hub Station on the current site of Wigan Fire Station. It also seeks support from Members to progress the development of a full business case and project plan for delivery. EXECUTIVE SUMMARY 1. Greater Manchester Fire and Rescue Service (GMFRS) and North West Ambulance Service (NWAS) have been working on plans to design and build a shared Fire and Ambulance Station at the current site of Wigan Fire Station. 2. This work has resulted in a design that maximises shared space on the site allowing for closer working and understanding between our two organisations. The design could provide a blueprint for greater collaboration in other parts of Greater Manchester. 3. High level costs and models for funding the project have been developed with the NWAS Board considering and approving an outline business case for progression at their meeting on 25 March 2015. 4. To progress the potential scheme further it will now be necessary to develop a full business case and supporting project plan for consideration by Members and the NWAS Board 5. In the event of a failure to agree or gain approval from either Members or the NWAS Board, the original plan to build a replacement station for fire only will be reinstated. 6. This paper seeks the approval of Members to invest in the development of a full business case and project plan. INTRODUCTION/BACKGROUND Background to Collaboration 7. Through discussion with NWAS it became clear that they are looking to move to different delivery model involving a ‘hub and spoke’ approach that would enable them to rationalise their assets. 8. As a consequence a decision was taken, and approved by Members, to delay the progress of the project so that a more collaborative approach involving the development of a joint Fire and Ambulance hub could be explored. 9. The objectives of this scheme would be to co-locate the current Wigan Fire Station and a number of ambulance sites onto one site at Wigan. The benefits from co-locating include: Enablement of more effective working between partners, including improved understanding of each other’s roles Development of a more collaborative approach to risk reduction Delivery against some of the objectives set out in the ‘Knight Review; Facing the Future’ Reduced capital and revenue costs Potential for NWAS to realise savings through the sale of assets 10. If progressed the project will also deliver against a number of the key principles of the Joint Emergency Services Interoperability Programme (JESIP), which include: Joint training and exercising Shared organisational and cultural awareness Shared information and intelligence Joint understanding of roles Joint procurement and sharing of resources 11. As the approach to the delivery of public services evolves, visible collaboration with other services, such as this, will assist in changing the culture and expectation of both staff and the public regarding greater integration. Requirements For A New Fire and Ambulance Station GMFRS 12. Wigan Fire Station was built in 1964 and, although functional, requires significant investment annually to maintain it and has running costs that are significantly higher than those for a modern building. A plan to replace the current building with a new station similar to those at Bury and Rochdale was scheduled to commence in June 2014. 13. An analysis of fire cover requirements in the Wigan area determined that the most appropriate location for a new fire station is the current site at Robin Park Road. 14. With this in mind plans were developed to demolish the existing building and rebuild on the same site. This included plans to convert the existing garage space, at the rear of the site, into a temporary fire station for the duration of the project. 15. Members will recall that the schemes at Bury and Rochdale were delivered by Kier Construction Northern. At the time Kier Construction Northern were only contracted to deliver two fire stations and therefore could not automatically be used for the delivery of a new station at Wigan. 16. As a consequence a procurement exercise to appoint a contractor for this scheme was commenced using the North West Construction Hub (NWCH). As part of this process an initial feasibility study was undertaken by Kier Construction Northern, via the NWCH with design input from architects Bradshaw, Gass and Hope. The scheme was in the early stages of selection of a contractor when NWAS expressed an interest in taking part. The GMFRS only activities were therefore suspended at that point, and new work was commended based on revising the scheme to incorporate the requirements of NWAS. NWAS 17. Senior NWAS managers expressed an interest in co-locating on the Wigan Fire Station site in May 2014. The NWAS Greater Manchester (GM) West group is comprised of 5 ambulance stations, Wigan, Hindley, Atherton, Standish and Billinge. These stations were built in the 1960’s and require varying degrees of refurbishment and ongoing maintenance. The group has 136 operational staff resourcing 20 emergency vehicles. 18. NWAS are seeking to modernize their approach to the delivery of their services through the introduction of a ‘hub and spoke’ model that will enable them to rationalise the number and size of ambulance stations. GMFRS’ intention to rebuild a fire station on the site at Robin Park Road, presented an opportunity for NWAS to consider the use of the site as a hub for their GM North West group. 19. The introduction of this approach in Wigan will enable NWAS to realise cashable savings by reducing the size and maintenance costs for their estate; and through the sale of existing estate assets. CURRENT POSITION 20. A multi-agency project board has been established to consider the options for the development of a joint fire and ambulance hub on the site. Plans have been developed and both NWAS and GMFRS staff consulted on the design. Significant progress has been made in maximising the amount of space that could be shared by both organisations. The current site footprint will not accommodate all the requirements and it will be necessary to acquire the vacant land to the South West of the site, which is currently owned by Wigan Metropolitan Borough Council (WMBC). Site and proposed building plans are included at Appendices A and B. 21. Discussions to resolve the basis on which the vacant land is acquired are being progressed by financial leads from NWAS, WMBC and GMFRS. 22. A number of potential cost models have been mutually explored and have resulted in development of two financial options that have been previously presented to Chairs and Corporate Leadership Team and have now been presented to the NWAS Board. These include: NWAS to share capital and revenue costs for the new station 50:50 with GMFRS GMFRS to provide 100% of capital funding, 50% recovered over the period of a 30 year lease with revenue costs shared on a 50:50 basis. 23. Due to the potential impact of NWAS’s VAT arrangements the most cost effective option would be for GMFRS to provide 100% of capital costs and recover 50% over the period of a 30 year lease. Both NWAS and GMFRS have sought independent VAT advice, which has clarified that there would be no adverse impact on GMFRS from such an arrangement. 24. At its meeting on 25 March 2015 the NWAS Board approved the outline business case for this collaboration with a view to a full business case being developed and presented to the Board in July 2015. Their preference is the adoption of a cost model where GMFRS provide 100% of capital funding. OPTIONS/ALTERNATIVES 25. Whilst a number of options, outside of those considered here, exist to secure a new station at the Robin Park Road site only three present a realistic opportunity to progress; Develop and implement a fully costed project, for final approval by the Fire Authority and NWAS Board, to demolish the existing building and rebuild a joint fire and ambulance hub on the same site with 100% of capital funding provided by GMFRS from reserves. Develop and implement a fully costed project, for final approval by the Fire Authority and NWAS Board, to demolish the existing building and rebuild a joint fire and ambulance hub on the same site with capital funding shared equally between NWAS and GMFRS. GMFRS contribution to be provided from reserves. Revert to the original concept of replacing the existing station with a new one built for fire only. This option would be progressed regardless, in the event of NWAS board not providing approval for a full business case. PREFERRED OPTION 26. In the spirit of collaboration and to achieve the positive benefits set out above, it would be preferable to progress with the design and delivery of a joint fire and ambulance hub rather than a ‘fire only’ option. 27. If a 50:50 capital funding arrangement were adopted this would result in NWAS incurring additional costs for VAT of potentially £0.5million, significantly reducing the financial benefits to them and potentially making the project undeliverable. 28. For these reasons the preferred option is for the design and delivery of a joint fire and ambulance hub with GMFRS bearing all associated capital costs. The NWAS contribution towards capital costs to be recovered through a legally binding agreement over a period of 30 years. CONSULTATION 29. NWAS and GMFRS staff have been consulted through the development of the initial plans and outline business case. As the project will require support from others in the vicinity of the site consultation will take place with local residents and businesses, in particular the ASDA store on Robin Park Road who have already indicated that they can support the project through the provision of parking arrangements throughout any demolition and build phase. RESOURCES IMPLICATIONS 30. a) Financial and Procurement Capital Costs The estimated capital cost for the revised scheme is £4.5million full details are set out in Appendix C(i)). This includes for demolition of the current fire station, building works, external works and associated design fees. This estimate has been provided by Bradshaw Gass and Hope, consultant architects used as part of the feasibility stage referred to in paragraph 16 above and based on the latest design agreed between both parties. It is anticipated that additional skills will be required to support the scheme, in the form of a Quantity Surveyor, Employers Agent and Clerk of Works. This can be accommodated within the project budget included above. Arrangements at the end of 30 year term A share of any capital receipt at the end of the 30 year term, (based on valuation at that point by the District Valuer) is assumed for the 50:50 capital model only. For the GMFRS capital model it is assumed that there is no share of any capital receipts at the end of the 30 year term, with ownership remaining with GMFRS. Revenue Costs Revenue costs have been calculated based on the cost per square metre of GMFRS newest sites at Bury and Rochdale, with an assumed 50% share of revenue costs for both parties. Revenue costs included in the models are as follows: Recovery of 50% of capital costs from NWAS - revenue only model Costs of utilities –based on costs at our newest and most efficient sites at Bury & Rochdale Rates – based on current cost at Wigan site Servicing and planned maintenance for the site – estimated on current costs of services provided for GMFRS An estimate for the whole life cost of replacing boilers, electrical rewires, new lift and re-roofing Procurement It is intended that the North West Construction Hub will be used for selection of a contractor, using their new Medium Value Framework for contracts with a value between £2m and £9m. This will be led by GMFRS with input and consultation at all stages with NWAS. 31. b) Human Resources (including Equality & Diversity Implications) Although staff will share accommodation, there will be no staff shared between organisations. As a consequence HR issues will be dealt with by NWAS and GMFRS HR functions in the normal manner. The project will result in a significant amount of additional work within the Estates and Facilities team. It is therefore intended to recruit an additional bespoke resource within the team to accommodate the delivery of this and other key projects. Approval for this will be sought from the Corporate Leadership Team and Members once a full business case has been developed. 32. c) Legal and Constitutional The principal legal documents will consist of: An agreement for a lease during the construction phase A lease upon completion of the building The heads of terms for the lease will deal with: The Term – 30 years The Property – the areas to be occupied The Rent Break Options and consequences Rent Review Option to Renew Rent on Renewal Landlord and Tenant Act 1954 Permitted Use Permitted Assignment Insurances Running Costs Sinking Fund Advice and assistance will be sought from the Authority’s Solicitor throughout the life of the project, and lawyers specialising in property work will be engaged as appropriate. 33. d) Health & Safety GMFRS and NWAS’s Health and Safety Departments will be consulted throughout the project. 34. e) Sustainability New buildings offer an opportunity for significant reductions in environmental impact using the latest sustainable technology. This impact will be managed through the procurement process, ensuring that sustainability criteria are built into the specification for the new building. In the case of the Bury and Rochdale new builds this included a specific commitment to reach the BREEAM 'Excellent' rating. The indicative scheme costs allow for a similar standard. This new technology results in significant savings on running costs. At Bury there have been savings of up to 90% on heating and lighting bills. Each new Fire Service building is more efficient than the last. Rochdale Community Fire Station opened in December 2013 and achieved an incredible A+ rated energy performance. It generates more energy than it uses. RECOMMENDATIONS 35. Members are requested to: a) Note progress to date. b) Approve further work to develop a full business case and project plan; to be approved by the Fire Authority and NWAS Board. STEVE McGUIRK COUNTY FIRE OFFICER & CHIEF EXECUTIVE There are no background papers to this report within the meaning of Section 100D of the Local Government Act 1972. S. McGuirk (Proper Officer) 9.4.15