PLN 2014-0080 06214011 Sumner Southwest â SW Infiltration Rate
Transcription
PLN 2014-0080 06214011 Sumner Southwest â SW Infiltration Rate
& ASSOCIATES, INC. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION FORENSIC INVESTIGATION December 5, 2014 KA Project No. 062-14011 J. K. Monarch, LLC P.O. Box 188 Puyallup, WA 98371 Attn: Mr. Fred Herber Reference: Email: [email protected] Tel: (253) 840-5660 Sumner Southwest Stormwater Infiltration Rate 7420 148th Avenue Court East & 14712 72nd Street East Sumner, WA Dear Mr. Herber, As per your request, we have prepared this letter to provide stormwater infiltration rate recommendation for the Sumner Southwest project located at 7240 148th Avenue Court East/14712 72nd Street East in Sumner, WA. Stormwater Infiltration Rate We had previously prepared a geotechnical report titled “Limited Geotechnical Engineering Investigation – Sumner Southwest, 7240 148th Avenue Court East/14712 72nd Street East, Sumner, Washington”, dated October 21, 2014. At the time our limited geotechnical engineering investigation was prepared a stormwater management system consisting of infiltration pond in the southern portion of the site was being considered. We had provided infiltration rate of 2.0 inches per hour for a well-maintained infiltration system using the native sand with gravel and sand with silt in the southern portion of the site. We understand that the design team is currently considering permeable pavement to manage the stormwater. We have been requested to provide an infiltration rate for the design of the stormwater infiltration system consisting of permeable pavement. Our explorations indicated that the site is underlain by native alluvium soils. Our previous recommended infiltration rate was 2.0 inches per hour for a well-maintained infiltration system using the native sand with gravel and sand with silt in the southern portion of the site. Due to the variability of the site soils encountered in our test pits we have applied a safety factor of approximately 4 to the infiltration rate. We recommend using an infiltration rate of 0.5 inches per hour for the design of the permeable pavement stormwater infiltration system. The stormwater infiltration system should be designed by a Washington State Licensed Civil Engineer. 922Valley Avenue NW, Suite #C-101, Puyallup, WA 98371 (253) 939-2500 FAX (253) 939-8556 With Offices Serving the Western United States KA No. 062-14011 December 5, 2014 Page No. 2 Testing and Inspection We should evaluate the soil conditions during construction of the stormwater management system to confirm that the soil conditions are consistent with those encountered in our explorations. This activity is an integral part of our services as acceptance of earthwork construction is dependent upon observation of the consistency of the soil and groundwater conditions, and making appropriate adjustments if conditions vary from those indicated by our explorations. Limitations Geotechnical engineering is one of the newest divisions of Civil Engineering. This branch of Civil Engineering is constantly improving as new technologies and understanding of earth sciences improves. Although your site was analyzed using the most appropriate current techniques and methods, undoubtedly there will be substantial future improvements in this branch of engineering. In addition to improvements in the field of geotechnical engineering, physical changes in the site either due to excavation or fill placement, new agency regulations or possible changes in the proposed structure after the time of completion of the geotechnical letter may require the geotechnical letter to be professionally reviewed. In light of this, the Owner should be aware that there is a practical limit to the usefulness of this letter without critical review. Although the time limit for this review is strictly arbitrary, it is suggested that two years be considered a reasonable time for the usefulness of this letter. The recommendations made in this letter are based on the assumption that soil and groundwater conditions do not vary significantly from those disclosed during our field investigation. If any variations or undesirable conditions are encountered during construction, the geotechnical engineer should be notified so that supplemental recommendations can be made. The conclusions of this letter are based on the information provided regarding any proposed construction. If the proposed construction is relocated or redesigned, the conclusions in this letter may not be valid. The geotechnical engineer should be notified of any changes so that the recommendations can be reviewed and re-evaluated. This letter is a limited investigation with the purpose of evaluating the soil and groundwater conditions and providing laboratory testing. The scope of our services did not include any environmental site assessment for the presence or absence of hazardous and/or toxic materials in the soil, groundwater or atmosphere, or the presence of wetlands. Any statements, or absence of statements, in this letter or on any exploration log, regarding odors, unusual or suspicious items, or conditions observed are strictly for descriptive purposes and are not intended to convey engineering judgment regarding potential hazardous and/or toxic assessments. Krazan & Associates, Inc. Offices Serving The Western United States KA No. 062-14011 December 5, 2014 Page No. 3 The information presented herein is based upon professional interpretation utilizing standard engineering practices and a degree of conservatism deemed proper for this project. It is not warranted that such information and interpretation cannot be superseded by future developments. We emphasize that this letter is valid for this project as outlined above, and should not be used for any other site. If you have any questions, or if we may be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC. 12/05/14 Michael D. Rundquist, PE Senior Project Manager Vijay Chaudhary, P.E. Staff Engineer VC:MR Krazan & Associates, Inc. Offices Serving The Western United States