PRE-QUALIFICATION NOTICE - Pakistan Ordnance Factories
Transcription
PRE-QUALIFICATION NOTICE - Pakistan Ordnance Factories
For uploading on PPRA and POF website PRE-QUALIFICATION NOTICE 1. Applications are invited for pre-qualification of contractors for the following work so as to reach the office of the undersigned on 23-04-2015. Name of Work PROVISION OF HT/LT POWER SUPPLY AND INTERNAL ELECTRIFICATION OF HYDRAULIC EXTRUSION PRESSES PLANT TO BE INSTALLED AT EXPLOSIVES POF FACTORY, WAH CANTT. 2. Detail of BOQ is attached. 3. For pre-qualification, parties having experience, capability and resources may apply along with the following information and documents: i. ii. iii. iv. v. vi. vii. viii. ix. x. xi. xii. Name of the firm along with Postal Address, Phone & Fax #. Status of firm (Partnership deed, Article of association or Registration of firm’s certificate etc) Copy of incorporation certificate & organizational structure. P.E.C Registration in C-6 (Minimum) with specialization code EE-04, EE-05 and validity. Similar nature of works up to Rs. 10.00 million completed during last five years. Similar nature of works in hand alongwith names and addresses of clients. Pre-qualification for similar nature of works with Govt, Semi Govt, Public Sector.. List of Key Personnel & Details of Technical staff. NTN No. and Certificate of Professional Tax. Bankers Certificate showing credit worthiness & Auditor’s Report of last three years. Affidavit for Not Blacklisted or involved in arbitration / litigation with any client during the last five years. Proof of enlistment with other Organizations. 4. Those who fail to provide above mentioned Information / documents shall be disqualified. 5. After the completion of Pre-qualification, Tender documents will be issued to the selected prequalified firms upto 30-04-2015. Tenders will be received by the Director Services POFs Wah Cantt upto 1100 hrs on 07-05-2015 and opened at 1200 hrs on the same date. 6. Firms / contractors already working with POFs may also provide the information / documents of the ongoing projects. 7. GM-Electrical may be contacted at phone No. 051-9055-21099 & email [email protected] for further information. Tashhir ud Din (Director Services) C-O4 POFs Wah Cantt. Tele No. 051-905521090 Fax No. 051-9314100 BILL OF MATERIAL PROVISION OF HT / LT POWER SUPPLY AND INTERNAL ELECTRIFICATION OF HYDRAULIC EXTRUSION PRESSES PLANT TO BE INSTALLED AT EXPLOSIVE FACTORY, WAH CANTT. Sr.# A/U Qty 1. H.T end termination Kits make Raychem Germany (complete in all respect) for HT XLPE Power Cable 185mm²/3C . Supply & fixing. (Specifications are attached) supplied jointing kit will be tested at 33 KV Nos. 05 2. PVC striaght joint, HT, 11 KV for XLPE cable, consissting of mould resin, HT tape, semi conducting tape, ferrules & earth wire etc suitable for HT cables 3 core, 185mm2 Supply & fixing. (Specifications are attached) Make: Raychem Germany Nos. 03 Mtrs. 2000 Mtrs. 2000 5. PVC Cable 6mm2/4 Core, PVC insulated sheathed, 600/1000V with annealed stranded copper conductor as per BSS No. 6346, 1987 / IEC standards. Supply & fixing. Brands: Newage, AGE, Pakistan Cables. Mtrs. 2000 6. Indoor Termination Kit 240mm2/4 Core (Heat Shrinkable), complete with accessories, 1100 V, supplied jointing kit will be tested at 3300 V. Supply & fixing. Make: Raychem Germany. Nos. 12 7. Indoor Termination Kit 185mm2/4 Core (Heat Shrinkable), complete with accessories, 1100 V, supplied jointing kit will be tested at 3300 V. Supply & fixing. Make: Raychem Germany. Nos. 10 8. Indoor Termination Kit 300mm2/4 Core (Heat Shrinkable), complete with accessories, 1100 V, supplied jointing kit will be tested at 3300 V. Supply & fixing. Make: Raychem Germany. Nos. 15 3. 4. Nomenclature 1.5mm2/4 Core, 600/1000 V Electrical power cable PVC/PVC with stranded annealed copper conductor as per BSS / IEC standards. Supply & fixing. Brands: Newage, AGE, Pakistan Cables. 4mm2, 2 core, 600/1000 V Electrical power cable PVC/PVC with stranded annealed copper conductor as per BSS / IEC standards. Supply & fixing. Brands: Newage, AGE, Pakistan Cables. 9. 10. Bus bar chamber weather proof wall mounting, current rating 3000 Amps, 600 / 1000 V, 50 Hz. Completet with 3 phase and half neutral bus bars. Supply & fixing. Chamber shall be pre fitted complete in all respects with i) Incoming MCCB 6 Nos, 600 A rating, 25KA, TP for 300mm2 / 4 C cable size at chamber top front. ii) Outgoing MCCB 02 Nos, 600 A rating, 25KA, TP for 185mm2 / 4 C cable size at chamber bottom for supply to fire pump (110 KW, 1400A start current). iii) Outgoing MCCB 05 Nos, 600 A rating, 25KA, TP for 240mm2 / 4 C cable size at chamber bottom for supply to Chiller (360 KW, 700 A start current). iv) Outgoing MCCB 01 No, 600 A rating, 25KA, TP to connect 300mm2 / 4 C cable size for supply to 100 Ton Refrigeration plant. v) Outgoing MCCB 02 Nos, 300 A rating, 25KA, TP for 185mm2 / 4 cable size at chamber bottom for supply to Hyd drives (2x55 KW). vi) MISC MCCB 06 Nos, 50 A rating with adjustable O/L current setting at chamber bottom. Construction of Earth Pit for Kiosks, for areas having water table 4.5 meter depth as per detail given at Para 25.4 & Sr.No 25-469 of MES Schedule-2009. Set 01 Nos. 02 11. Construction of concrete foundations for Kiosks (8x7x1.5) Mtr. Nos. 02 12. Excavation and back filling of H.T cable trench 1500m x 0.91m x 0.46m complete. Cu. Mtrs. 628 13. Excavation and back filling of L.T. Cable trench 100m x 0.76m x 0.61m complete. Cu. Mtrs. 46 14. Perforted bottom with solid snap on lid cover cable tray of appropriate size approx. 6 x 24 inches (H x W) complete with support brackets and cable clamps. Supply & fixing. Mtrs. 200 15. Cable glands (Brass made) and cable end boxes. Supply & fixing. Nos. 50 16. Sand. Supply & laying in trench. CuFt 5200 17. Burnt Bricks. Supply & laying in trench. Nos. 14000 Note: 1. Supplier will be responsible for supply, installation & commissioning of above stated electrical items and any other accessories required for subject power supply. 2. The above mention items should be inclusive of all applicable taxes.