Remove Control Board from Cabinet Install the By-Pass
Transcription
Remove Control Board from Cabinet Install the By-Pass
QUICKSTART “BASIC” INSTALLATION GUIDELINES FOR AN 1812 ACCESS PLUS CABINET AND BY-PASS BOARD It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all the different types of installations. The 1812 Access Plus Telephone Entry System involves the installation of the 1812 cabinet, the by-pass board for the incoming telephone line, and wiring of these components (On reverse side). Be sure that all dirt, metal or wood debris is removed from inside cabinet after mounting it. This could damage the control board and cause a malfunction during operation. 1 4 7 2 5 8 0 1 3 4 6 7 9 2 5 8 0 1 3 4 6 7 9 4 The control board removal is the same for all models. J4 1 2 3 4 5 6 7 8 BA D DNJ1 S RS -48 RX 5 LA DO N RJ WN -4 Ja 5 (Catck 5) SW 1 MO DE 19 OV KE M CO DE 72 -01 0 Surface Mount Cabinet Surface Mount Curved Cabinet 19 18-Pin Main Terminal Connector 12 70 34 -01 J2 0 56 78 SP EA KE VO R L J1 J4 1 2 3 4 5 6 7 8 BA D DNJ1 S RS -48 RX 5 LA DO N RJ-WN Ja 45 (Catck 5) SW 1 ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 MO DE M CO DE 197 2-0 10 OV KE YP AD MI C VO L 197 0-0 10 12 J2 34 56 78 91 Remove the 18-pin main terminal connector, and if necessary, the 8-pin RS-485 connector from the control board by gently pulling them straight up. This will make wiring to the control board easier. Note the orientation and numbering sequence of each connector to correctly wire it. 0 11 6 9 120 Glasgow Avenue Inglewood, California 90301 3 5 6 8 9 Wall Mount Cabinet U.S.A. Flush Mount Cabinet “Entry” switch position: “By-Pass” switch position: Routes incoming phone line through 1812 Access Plus and then to the home phone. Routes incoming phone line directly to the home phone, bypassing 1812 Access Plus. ENTRY BY-PASS ENTRY BY-PASS SW1 SW1 1875-010 Mount Cabinet on a Mounting Post 1875-010 EARTH GND EARTH GND 1 2 3 CENTRAL OFFICE Use existing 4 holes in cabinet box to bolt the surface or wall mount models on a DoorKing mounting post (there are several different styles available). Use the hardware that is supplied with the mounting post. Run all necessary wires through the post to the cabinet (See reverse side). SP EA KE VO R L 3 The 1812 Access Plus by-pass board provides a method to by-pass the 1812 Access Plus and route the incoming telephone line directly to the homeowner’s phone. It must be installed as part of the 1812 Access Plus system. All telephone wires for the 1812 Access Plus must pass through the by-pass board. Mount the by-pass board in a location that is easily accessible by the homeowner. In case of 1812 Access Plus trouble or maintenance, the homeowner will use the by-pass switch on the board to route the incoming telephone line directly to their home phone. If the by-pass board is installed outdoors, it must be installed in a NEMA Type 4 enclosure (not supplied) with conduit to protect the board and wires from direct exposure to landscape sprinklers, rain, snow, and other elements. 8-Pin RS-485 Connector 91 0 11 8 Install the By-Pass Board YP AD MI C VO L 2 0 1. Unlock and open the 1812 Access Plus door. 2. Disconnect the keypad plug and door accessories plug from the control board. 3. Remove the 4 screws. Carefully remove control board. CAUTION Keep the control board in a protected area during the installation. J1 ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 7 IMPORTANT The 1812 Access Plus and by-pass board MUST be properly grounded! A gooseneck mounting post anchored in concrete does not make a good ground. 5 0 1 Remove Control Board from Cabinet 2 4 PHONE IN 5 6 PHONE OUT 7 8 1 2 3 CENTRAL OFFICE HOME Home Phone Incoming Phone Line 4 PHONE IN 5 6 PHONE OUT 7 8 HOME Home Phone Incoming Phone Line 4 7 5 6 8 9 4 7 5 6 8 9 0 0 Bolt flush mount box into the rough-in box with 4 supplied bolts. EN sh Flu nt u Mo x o B TR Y 1 EA R GNTH D 7 0 4 8 5 9 2 -PA 3 6 SS 4 1 Ground by-pass board. Minimum 12 AWG wire (Not supplied). Ro u gh -In CE 2 N OF TRAL FIC E Plastic screw anchors for masonry if required. (Not supplied) Bo x If installed outdoors. NE M en A Ty clo pe s 4 ou ure f t o ins doo r tal r (No la t S tio up plie n. d) (Sh Con ow du n in it sid ew all) Co n (Sh duit ow n in sid ew all) Mount Cabinet Directly to a Wall or Pilaster Flush Mount Cabinet in a Pilaster, Wall or Kiosk Mount rough-in box into the pilaster, wall or kiosk. Run conduit inside wall into bottom of rough-in box if desired. Use appropriate hardware (Not supplied) to secure the rough-in box in place. Run all necessary wires through the conduit in to the rough-in box (See reverse side). Use the 4 existing holes in the cabinet box to screw the surface or wall mount models to the wall. Run conduit inside or outside of wall or pilaster if desired. Use appropriate hardware to mount the cabinet (Not supplied). Be sure that the mounting hardware does not protrude into the cabinet where it could cause a short. Run all necessary wires through the conduit to the cabinet (See reverse side). Dedicated Telephone Wire Conduit From Incoming Telephone Line 3 ON4 IN E PH BY 5 SW 1 6 7 187 5 PH 6 O OUNE T 7 HO From 1812’s 18-Pin Main Terminal 5-08 10 8 ME From Home Phone Use only twisted pair telephone wire that is rated for direct underground burial (Cat5e Gel Filled (flooded) UV resistant direct burial cable in conduit is recommended). DO NOT use wire that is rated for indoor application use. DO NOT run telephone wires in the same conduit as high voltage AC wire. It is recommended to run all necessary wires to the by-pass board (See reverse side) in a “dedicated” telephone wire conduit. QUICKSTART “BASIC” WIRING GUIDELINES FOR AN 1812 ACCESS PLUS SYSTEM WITH ACCESS CONTROL DEVICE(S) It is highly recommended that you consult the Installation/Owner’s manual for complete wiring instructions on all the different types of installations, programming and internet connections. Basic Programming for the 1812 Access Plus 1875-010 1 2nd Line Yellow Older Residential Homes (-) Ring Orange Pair (+) Tip 3rd Line (-) Ring Phone Wiring Basics “101” Phone at Home #12 Cat5e Ring Phone at Home #13 TIP (+): White/blue mark RING (-): Blue/white mark Tip Ring Green Pair Modern Residential Homes (+) Tip 4th Line (-) Ring 8 HOME Cat5e 24 AWG 800 ft 22 AWG 1600 ft 20 AWG 2200 ft 18 AWG 3600 ft RING TIP Older Lines Green Wire (+) 1. Press * 0 3 and enter the MASTER CODE. [* 0 3 _ _ _ _ (beep)] 2. Enter “1” for relay 1 or “2” for relay 2, then press *. [ _ *(beep)] IMPORTANT All boards MUST be properly grounded or the system will NOT function correctly! AMPS MAX PHAS GATE DoorK LOAD E 60 ing, Hz Inc., Inglew ood, CA 4. Repeat steps 2 and 3 to set the other relay strike time if necessary. Electric Strike k loc g Ma Without Surge Board DO NOT power the 1812 Access Plus from a 24-Volt source (Such as a gate operator). Damage will occur to the 1812 Access Plus that is NOT covered under DoorKing’s warranty. “Normally Close” Pedestrian Gate/Door with Maglock (Terminal 15 and 16) “Normally Open” Pedestrian Gate/Door with Electric Strike (Terminal 14 and 16) Magnetic locks or electric strikes must be powered from a separate UL Listed power transformer. DO NOT power electric strikes or magnetic locks from the 1812 Access Plus power transformer. keep power wire runs as short as possible. Ground CAUTION Power Transformer and Access Control Device(s) Wire Run Table Wire Size Max Distance 18 AWG 100 ft 16 AWG OV 200 ft Over Voltage Power Note: LED located on bottom left corner of board will light up if too much power is applied to circuit board. 5 8 3 6 9 Daisy Chain Wiring t tpu Ou VAC .5 16 VA 20 Supplied Power Transformer Program MASTER CODE Phone In 1 RS-485 DATA A (+) RS-485 RX 2 RS-485 DATA B (-) RS-485 RX 3 RS-485 Common LAN DOWN BAD DNS LAN DOWN 4 MODEM/ TCP ENB BAD MODEM / TCP ENB SW1 DNS Switch Turned ON 5 LAN 6 CONNECTION DATA TRANSMIT PHONE LINE IN USE J1 J1 7 PHONE LINE IN USE 8 Connector (Cat5) RS 485 Terminal 1972-010 (1-2) 2 TIP 3 GND 4 TIP Phone Out (4-5) 5 RING 6 7 8 9 10 11 N.O. 12 N.C. Relay 1 Note: Each relay can control a 13 Com (11-13) normally open OR normally close access control device. Relay 14 N.O. Relay 2 contacts are rated for 3 amps @ 15 N.C. (14-16) 30 VAC maximum. 16 Com 17 16.5 Power 18 VAC (17-18) Green Pair 5. Press “0 #” TOGETHER to end. [0 # (beeeeeep)] Separate UL Listed Power Transformer J1Terminal 1 RING Ground 12 AWG Min. Recommended CONF ORMS ANSI/ UL-32TO CAN/CCERT 5 SA IFIED VEHI C22.2 TO CULA NO. 53382 CLAS 247 R S GATE MODE OPER L ATOR SERIA HP L VOLTS “Normally Open” Vehicular Gate Operator (Terminal 11 and 13) 2 0 Master Code LED Description J4 Main Orange Pair Recommended tions. 7 ON NG instruc 4 Phone Jack Cat5e Ground 3. Enter a two-digit strike time (00-99), then press *. [ _ _ *(beep)] Note: Strike time entered in seconds. 00 = ¼ sec., 10 = 10 seconds, etc. NI 1 Phone Jack Control Board Programming Relay 1 and 2 Strike Time - (Factory default is 1 second) WAR Separate UL Listed power transformer if needed. 6 Devices Maximum Access Control Devices gate. is ctions. n to in pathnot stand sight play while in in gate Read gate gate area is path owner movin or ’s manua g. walk throug l and h safety RS 485 Remote Device(s) See Installation/Owner’s manual to configure the RS 485 access control device(s) (device address, termination switch, programming etc). DO NOT power RS 485 device(s) from the 1812 Access Plus power transformer. Older Lines Red Wire (-) “Existing” Alarm System MOV SER ING IOUS GAT Operat INJUE CAN and e free gate RY CAU of only Do OR people when or not allow DEASE and gate operat obstruarea TH e childre Do This “Quickstart” guideline is designed for installing a single 1812 Access Plus in a typical single family home application using the factory default settings programmed in the 1812 Access Plus. Complete installation instructions and programming manual is available on the enclosed CD AND from our tech support web site. CLICK HERE TO VISIT DOORKING’S TECHNICAL WEB SITE: www.dkaccess.com/english/Telephone_Entry/telephone_entry.html. Homeowner’s Phone(s) Cat5e U.S.A. Complete Instructions DO NOT run telephone wires in the same conduit as high voltage AC wire. Green Pair Cat5e Ground 120 Glasgow Avenue Inglewood, California 90301 Check for polarity on the incoming telephone line to each board and maintain polarity throughout the telephone line (TIP (+), RING (-). Cat5e Without Surge Board To “Existing” Alarm Control Panel Max Distance Check Polarity of Telephone Line TIP RING RING TIP TIP Orange Pair Brown Pair RJ31x Phone Jack installed Before 1812 System Locate Homeowner’s Phone Line Inside Device 7 Wire Size Cat5e Gel Filled (flooded) UV resistant direct burial cable run in conduit recommended. Ring Tip 6 PHONE OUT Cat5 Wire (+) Tip Blue Pair Black 5 Ring (-) Ground 12 AWG Min. 1st Line 4 PHONE IN RING Tip (+) Red 3 TIP RING RING RING GND GND 2 CENTRAL OFFICE PHONE LINE INPUT OUTPUT Cat5e Phone at Home #11 Central Office (C.O.) Demarcation Device Tip SW1 EARTH GND TIP Wire Conversion Green ENTRY BY-PASS 1877-010 Ground 12 AWG Min. Within 3 ft of Board Use common electrical safety practices when connecting telephone wires. You can receive a substantial jolt if the phone rings while handling these wires.“RING” terminal voltage varies and can be between -48 to -130 Volts AC, depending on the distance to the central office.“TIP” terminal is always positive with respect to RING terminal. Four Conductor Wire The By-Pass board is required. Optional P/N 1877-010 Recommended Telephone Company Demarcation Point By-Pass Board Phone Line Surge Suppressor TIP The 1812 has been programmed at the factory with many of the programming parameters (default setting) set for a typical residential application with a single 1812 Access Plus. However, you must program a “Master Code” before putting the 1812 Access Plus into service. If you are using more than a single 1812 Access Plus in the system, or if you are using any of the advanced features of the 1812 Access Plus , such as Time Zones, Do-Not-Disturb Schedules, Call Forwarding, Holiday Schedules, Hold Open Schedules, Directory Code Dial-Out Phone Numbers, Temporary Access Codes, etc., you will need to download the complete Installation/Owner’s and Programming Manual from our tech support web site. Telephone and RS 485 Wire Run (Cat5e) Table MASTER CODE Blinking LED - Power is applied to the 1812 Access Plus and the processor is working (Normal Mode). LED ON Continuously - After master code push button has been pressed, system will be in Master Code programming mode. (Will revert back to blinking LED if master code is not entered within 10-seconds). Push Button to Program “Master Code” 1. Press the Master Code push button. (the LED will stay on continuously). J3 Cat5 Cable MIC VOL KEYPAD 1970-010 SPEAKER VOL J2 OV 1 2 3 4 5 6 7 8 910 11 Polarity does not matter. 2. Enter a four digit Master Code number then press “ ”, “beep” will be heard. * [ _ _ _ _ (beep)] (Write down master code). To LAN/Router/Gateway See Installation/Owner’s manual for different connections to the internet. MODEM/TCP switch must be ON. Programming Simple Access Codes Ground 12 AWG Min. Within 3 ft of Board Programming Simple Access Code(s) to Operate Relay 1 and/or 2 on a 24/7 Basis - (Maximum of 50 codes) Ground OUT OUT GND GND IN OUTPUT INPUT LOW VOLTAGE LINE IN Low Voltage Surge Suppressor Optional P/N 1878-010 1. Press * 0 2 and enter the MASTER CODE. [* 0 2 _ _ _ _ (beep)] 2. Press 1 for relay 1 OR Press 2 for relay 2, then press . [ _ (beep)] * * 3. Choose and enter a five-digit simple access code, then press *. [ _ _ _ _ _ *(beep)] 4. Repeat steps 2 and 3 to enter additional simple access codes. 1878-010 Copyright 2011 DoorKing, Inc. All rights reserved. 5. Press “0 #” TOGETHER to end. [0 # (beeeeeep)] 1812-168-D-12-11