illmod 600 12.02.02 2002 18542 since 1999 fire retardant resin

Transcription

illmod 600 12.02.02 2002 18542 since 1999 fire retardant resin
illmod 600
Product Information
Short Description
illmod 600 is an impregnated, precompressed foam tape. Since 1965,
this tape has proven itself in driving
rain resistant joint sealing in aboveground buildings.
Since January 11, 1999, illmod 600
complies with all parameters required by DIN 18 542 according to
BG1 by the terms of the ift Test
Report of January 11, 1999.
Consistent high quality is ensured by
permanent in-house and independent
monitoring.
Material
Open-cell flexible polyurethane foam
impregnated with a flame-retardant
artificial resin.
Colours
● Anthracite
● Grey
Product Advantages
● Independently monitored during
driving rain resistance up to 600 Pa
(by MPA Bau (Construction),
Hannover)
● Open to water vapour diffusion
● Self-adhesive on one side to facilitate installation
● Can be coated with commercially
available vinyl emulsion paints
● Meets the RAL-Assembly Requirements
Availability
On pre-compressed rolls, self-adhesive
on one side.
illmod 600
Technical Data
illmod 600
DIN
4102
52 612
52 615
Building material class
Conductivity
Resistance to water vapour diffusion
Temperature resistance
Resistance to plant roots
Air permeability of joints
Weather resistance
Grouping
Driving rain resistance
4062
18 055
53 387
18542
18 055
Compatibility with other building materials
52 453
Long-term durability
Shelf life
Storage temperature
Classification
B1 (fire-resistant) P-NDS 04-229
λ 10 0.055 W/m · k
100
– 30 °C to + 90 °C
meets requirements
a 0,1 m3/[h · m · (daPa) n]
meets requirements
BG1
meets requirements up to 600 Pa for the
given operating range, externally
monitored by MPA Bau (Construction)
Hannover
no evidence of corrosion with iron, zinc,
steel, galvanised sheet and copper; no
harmful interaction with concrete, foam
mortar, clay brick, sand-lime brick, hard
PVC, plexiglass and wood. Additional
materials on request.
10 year functional guarantee *
2 years
+ 1°C to + 20 °C
01/02
*according to specific conditions provided by the manufacturer (available on request)
Dimensions/Sizes
Order No.
Joint depth/Joint width
in mm
8/
2
10/
2
15/
2
20/
2
8/
10/
15/
20/
illmod 600
Operating range*
Joint width
in mm
2
3
3
3
3
3
12/3 – 7
15/3 – 7
20/3 – 7
3– 7
Order No.
Joint depth/Joint width
in mm
15/ 5 – 10
20/ 5 – 10
Operating range*
Joint width
in mm
5 – 10
Order No.
Joint depth/Joint width
in mm
30/13 – 24
40/13 – 24
Operating range*
Joint width
in mm
13 – 24
15/ 7 – 12
20/ 7 – 12
7 – 12
35/17 – 32
40/17 – 32
17 – 32
20/ 8 – 15
30/ 8 – 15
8 – 15
40/24 – 40
50/24 – 40
24 – 40
20/10 – 18
25/10 – 18
30/10 – 18
10 – 18
* Movement of building components and changes in length related to temperature should be taken into account in measuring specific joint widths.
Application
illmod 600
Tools
Fitting requires a tape measure, a
spatula, scissors or a knife and possibly a wooden wedge.
Application
● Select the correct tape dimension
(see table) after determining the
width of the joint.
● Cut off the beginning (or end) of
the tape that is too compressed.
● While cutting the tape to the appropriate length, add 1 cm per
metre.
● Start application from the bottom
up in vertical joints. Butt-joint the
ends of the tape.
● The sides of the joint should be
parallel
(maximum
deviation
3 deg.). Furthermore, both sides
must be cleaned of any rough remains like mortar and dirt.
● For aesthetic reasons, the tape
should be fitted 1 – 2 mm from the
front edge of the joint.
● The self-adhesive side of the tape,
which facilitates the application,
can be neutralised by wet joints. In
this case, fix illmod 600 with
wedges during the expansion time
(Fig. 2).
● Please check the specific compatibility with paints, coatings, sealants
and natural stone.
Product Range
Joint Sealant Tapes
PU-Foams
Butyl Tapes
Sealant Foils
Special Products
Accessories
Fig. 1: Take application in window corners
Fig. 2: Butt-joint in solid type construction
Fig. 3: Butt-joint for window installation
Fig. 4: Cross-joint
Attention: Avoid tape contact with
solvents or corrosive chemicals.
Application Tips for Cross
Joints
● Pay attention to a flush fit of the horizontally or vertically butted surfaces
in a cross-joint (Fig. 4).
Application Tips for Window
Installation
● Do not apply illmod 600 around
the corner of the window frame
(Fig. 1).
● The tape must be butt-jointed (Figs.
1 & 3).
Application Tips for Solid
Type Construction
● Do not compress the tape excessively during the assembly of prefabricated building parts.
● The use of a water repellent on the
sides of the joint of very porous
surfaces is recommended before
mounting illmod 600.
● Take care that the adhesive side of
the tape is applied on the surface
of horizontal applications.
Service
illbruck’s application technology is always available to support and advise
you on request.
Additional information
The afore-mentioned information only contains
general recommendations. Due to the many different conditions in which applications take
place, on which we can exert no influence, and
the multiplicity of many different materials, extensive preliminary testing is recommended to
examine the characteristics of the material for
each specific application.
Manufacturer’s data as of 01/02. Subject to technical modifications.
illbruck Bau-Technik GmbH · Burscheider Straße 454 · D-51381 Leverkusen · Tel. + 49 (0) 21 71- 391-0 · Fax + 49 (0) 21 71- 391-586
www.illbruck-sealantsystems.com · e-mail: [email protected]