BioCOATBOND LIGHT

Transcription

BioCOATBOND LIGHT
Reference standard:
EN998-1
BioCOATBOND LIGHT
FIBRE REINFORCED LIME BASED SMOOTHING ADHESIVE FOR BONDING
AND SMOOTHING EXTERNAL WALL INSULATION SYSTEMS AND FOR
SKIMMING CRACKS IN VARIOUS SURFACES
GRANTS LEED CREDITS
CHARACTERISTICS
ONE-COMPONENT
Bioconfort
Line
ENVIRONMENTAL
WATER
BASED
ALLOWS
TO BREATHE
ECO GREEN
METHOD OF USE
MIX
MECHANICALLY
RECYCLABLE
PROBLEM
APPLY BY
TROWEL
APPLY BY
INOX SPATULA
STORAGE:
IN A DRY PLACE
SOLUTION
APPLICATION FIELDS
The insulating panels used for all-over insulation of houses require secure bonding to make them stable over time.
BioCOATBOND LIGHT is a levelling adhesive
based on natural hydraulic lime (NHL), reinforcing fibre, special resins and selected light aggregates and additives to improve workability
and adhesion.
BioCOATBOND LIGHT is a product used in
every all-over insulation system, and specifically for panels in mineral wools and natural fibres,
polystyrene, polyurethane and calcio-silicate.
Ideal as a leveller on old plastic coatings, or
on concrete surfaces with adhesion problems,
brick surfaces, tuff, stone or mixed materials.
AC C
DIN
G TO
EU R O P E
EN
AN
RMS
NO
OR
BONDING AND LEVELLING
INSULATING PANELS FORMING
PART OF AN ALL-OVER
COATING FOLLOWING THE
BIO-CONSTRUCTION RULES
APPLY BY
TOOTHED SPATULA
PRECAUTIONS
998-1
MORTARS FOR
RENDERS
LW
LIGHT MORTARS
FOR EXTERNAL RENDERS
AND INTERNAL PLASTERS
Smoothing adheives for exterior insulation systems
Marking
ADVANTAGES
B
• Easy-to-use one-part product.
• Secure adhesion.
• High breathability.
METHOD OF USE
Kg
25
ON
ICATI
URE
UM APPL
ERAT
MINIM
TEMP
THE
BREA
WS TO
ALLO
MIC
CERA
LIGHT
TBONDLine
BioCOBioAconfort
NI
ESTER
NI ED
NI
INTER
ESTER
PER
NI ED
ERTO
NI
INTER
PO AP
ESTER
PER
O TEM
NI ED
ERTO
LUNG
INTER
TERNI
PO AP
CON
PER
ED ES
O TEM
RALI
ERTO
ERNI
NATU
LUNG
TERNI
PO AP
R INT
TRE
CON
ED ES
O TEM
TO PE
RALI
HE, PIE
ERNI
NATU
APER
LUNG
E
N
INT
PO
TR
CO
PER
R
, PIE
H
O TEM
RALI
ERTO
S TRAS
IVO PE
MICHE
NATU
LUNG
EROU
PO AP
DANG
ADES
TRE
CON
CERA
NONLI
R
PIE
TEM
,
O
RA
HE
IVO PE
NATU
LUNG
LE
RAMIC
ADES
TRE
CON
CLAB
R CE
RECY
RALI
HE, PIE
IVO PE
E
NATU
TIBIL
RAMIC
ADES
ES
TRE
OMPA
PLAC
R CE
ECOC
DRY
HE, PIE
E IN
IVO PE
STOR
RAMIC
ADES
E
IED
R CE
APPL
LABIL
RICIC
TO BETROWEL
IVO PE
BY
ADES
• PREPARING THE SUB-BASE
In the case of old, crumbling plaster it is always
advisable to apply a coat of PRIMER FIX to fix
the powdery parts.
• PREPARING THE MIX
BioCOATBOND LIGHT should be mixed with
about 27% of clean water (about 5.40 litres per
bag) using a mechanical stirrer at low speed,
until a uniform paste free of lumps is obtained
(1). The mix remains workable for about 3-4
hours, depending on the climatic conditions.
• APPLICATION
BioCOATBOND LIGHT is used to bond panels
in expanded and extruded polystyrene, polyurethane, wood fibre, glass fibre, mineral fibre
and cork. Spreading should be carried out with
a notched or saw-toothed trowel. We recommend also applying to the edge of the panel to
improve stability.
The panels should then be applied to the walls,
exerting light pressure (3). For spreading, always start at the bottom, advancing uniformly
layer by layer towards
the top, with the panels
horizontal.
After at least 24 hours
BioCOATBOND LIGHT
can be used as a skimming layer over the surface of the insulating
panels, embedding in
the first skimming coat a
glass fibre reinforcement
of RETINVETRO PER
RASANTI (4) (the mesh
must be pressed with a
smooth trowel onto the
(See following)
6. Finishing
DECORPLAST
5. Render
BioCOATBOND LIGHT
4. Render
BioCOATBOND LIGHT
with RETINVETRO
PER RASANTI
3. Mechanical fixing
1. X-LAM wall
2. Heat-insulation panel THERMOSILENTRock
bonding with BioCOATBOND LIGHT
View the
application video
on your
smartphone
4th DIVISION
1st LINE
TECHNICAL CHARACTERISTICS
BioCOATBOND LIGHT
Standard
Class and type
Resistance to compression - after 28 days
Resistance to bending - after 28 days
Adhesion
Water absorption through capillarity
Water vapour permeability coefficient
Thermal conductivity l10,dry
Durability
Thermal resistance - Working temperature
Reaction to fire
Hazardous substances
1.30 ± 0.05 kg/
about 12
approx. 3-4 h
+5°C to +35°C
1 mm
10 mm
Manual or mechanical
Standards
Product performance
EN 998-1
EN 1015-11
EN 196-1
EN 1015-12
EN 1015-18
EN 1015-19
EN 1745 A.12
EN 998-1
LW
≥6 N/mm² - CS III
≥3 N/mm2
≥0.8 N/mm² - FP: B
w ≤ 0.4 kg/m²·h0.5 - W1
µ = 12
0.27 W/mK
5.2.3.2 compliant
-30°C to +90°C
A1
According note in ZA.1
EN 13501-1
EN 998-1
Test conditions: temperature 23±2°C, 50±5% R.H. and air velocity in test area <0.2 m/s. These parameters may vary based on the specific conditions of the worksite:
temperature, humidity, ventilation, porosity of the substrate.
(*) The stated times may be longer or shorter as the temperature decreases or increases.
Compliant with the general principles defined in EN 998-1 - Principles for evaluation of the use of products and systems.
(See previous)
fresh layer of the mix
and overlapped at the
joints by at least 10
cm). It is advisable not
to use the product on
panels with a "skin" as
they are totally resistant to adhesives. We
recommend fixing
the panels additionally with suitable mushroom head plugs.
The length of the plugs chosen should be
increased by the thickness of the insulation. Adjust the depth of the holes to suit
the length of the plugs +10 mm, and drill
the holes only after the adhesive has hardBioCOATBOND LIGHT can be used with any
thermal insulation panel in any series of layers of
all-over thermal insulation.
ened (after about 24 hours). The number of
plugs needed is about 6 per m², but can be
increased in specific areas which are particularly stressed.
• COVERAGE
When used as an adhesive, coverage is
3-5 kg/m2; as a skim coat, 2-3 kg/m2.
• PRECAUTIONS
• Use cold water in the summer and water at
20°C in the winter.
• Application temperature from +5°C to +35°C.
• Do not add water when the mix starts to set.
• Do not add other materials such as cement,
aggregates, additives.
• In hot weather, keep the surface of the laid
mortar wet, preventing the product from
drying out quickly, for at least 24 hours.
• Do not apply on smooth surfaces.
• Use only on panels without a "skin".
• We recommend consulting the specification
"ALL-OVER THERMAL INSULATION AND
THERMAL INSULATING PLASTERS".
• Clean tools with water and the coated surfaces with a wet cloth immediately after
laying.
• Do not expose the material to the sun in hot
weather.
• Store in original closed packaging in a dry place. Protect
against frost and high temperatures.
ISOLAMENT
DELLE FACCIATEO TERMICO
DEGLI EDIFICI
L’isolamento termico
a cappotto e intonaci
4
the numerous possible uses and the possible interference of conditions or
elements beyond our control, we assume no responsibility regarding the results
which are obtained. The purchasers, of their own accord and under their own
responsibility, must establish the suitability of the product for the envisaged use.
Performance characteristics
EN 1015-6
Powder
Beige
0 to 1 mm
1.05 ± 0.05 kg/
27% ± 1%
12 months
termoisolanti
L’obiettivo dell’isolamento
socio del GBC
Italia
termico è quello
rico per prevenire
di ridurre
l’effetto serra
dovuto all’immissionei consumi delle risorse energetiche
L’isolamento termico
dei gas inquinanti
e di ridurre l’inquinamento
produce un aumento
che si formano
esterno dell’abitazione,
atmosfedel benessere
in tutti i processi
riduce i costi e
e confort abitativo
di combustione.
risolve i problemi
L’azione dell’isolamento
grazie al ridotto
di condensa e
scambio termico
termico rallenta
formazione di
gia necessaria
tra interno ed
la diffusione di
muffe.
per il riscaldamento
calore attraverso
invernale e per
Un edificio è normalmente
l’involucro dell’edificio
il raffrescamento
e riduce la quantità
costituito da vari
estivo.
sore e dal valore
di enerstrati di
di conducibilità
l (lambda) specificomateriali e quindi la sua conducibilità
Dal punto di vista
per ogni materiale.
termica globale
energetico il miglior
La conducibilità
dipende dallo
terno rimane più
spesglobale (U) viene
a lungo nella struttura isolamento termico è quello
espressa in W/m2
esterno, detto
dell’edificio e
Un sistema di
a cappotto, perché
K.
in estate previene
isolamento termico
il calore prodotto
il suo eccessivo
progettazione
deve essere efficace
all’ine messa
riscaldamento.
e duraturo e per
La normativa italiana in opera.
ottenere i migliori
rende obbligatorio
risultati è necessaria
l’isolamento termico
una accurata
e promuove quello
di edifici esistenti.
4 a DIVISIONE
1 a LINEA
PACKAGING
20-kg Sacks
5 a DIVISIONE
The figures shown are average indicative figures relevant to current production
and may be changed or updated by INDEX at any time without previous warning.
The advice and technical information provided, is what results from our best
knowledge regarding the properties and the use of the product. Considering
Appearance
Colour
Particle size
Apparent density
Mixing water
Storage in original packaging in a dry place
Mix properties and workability
Density of the mix
pH of mix
Duration of workable mix (*)
Application temperature
Minimum application thickness
Maximum application thickness per layer
Application
Internet: www.index-spa.com
Informazioni Tecniche Commerciali
[email protected]
Amministrazione e Segreteria
[email protected]
Via G. Rossini, 22 - 37060 Castel D’Azzano (VR) - Italy - C.P.67
Index Export Dept.
T. +39 045 8546201 - F. +39 045 518390
[email protected]
© INDEX
socio del GBC Italia
agg050716
11/2014ted-6/2014
• FOR ANY FURTHER INFORMATION OR ADVICE ON PARTICULAR APPLICATIONS, CONTACT OUR TECHNICAL OFFICE • IN ORDER TO CORRECTLY USE OUR PRODUCTS, REFER TO INDEX TECHNICAL SPECIFICATIONS •