TotalGlove brochure (Engels).indd
Transcription
TotalGlove brochure (Engels).indd
A safe feeling Stay in touch with your second skin A breakthrough solution Latex allergy explained Total Glove Company Sdn Bhd (Total Glove) is the joint venture company of Latexx Partners Bhd and the Dutch based R&D company Budev BV. An allergy is a hypersensitive immunologic response to a substance, i.e. the allergen. I N N O VAT I O N I N L AT E X P R O T E C T I O N MPXX TM stands for Maximum Protection Latex and entails a unique global patented batch washing SYMP TOMS The symptoms of Type I allergy are amongst others urticaria (hives), hay fever type of symptoms and allergens are reduced to unquantifiable levels, PROTEINS AND ALLERGENS Raw latex contains approximately 200 different types asthma. More severe symptoms occur such as With Latexx Partners being one of the global leading manufacturing companies of examination gloves this including the major allergens Hev b1, Hev b3, of proteins. Fourteen proteins are listed by the WHO as drop in blood pressure resulting in a possible loss of set-up combines constant and reliable product and Hev b5 and Hev b6.02. Furthermore the chemical an allergen, whereby it is clinically proven that four of consciousness or severe breathing difficulty. service levels with the breakthrough technology for residues, such as thiurams, dithiocarbamates and them are the major allergens. These four are called Hev eliminating Natural Rubber Latex (NRL) allergens and mercaptobenzothiazoles, are reduced to undetectable b1, Hev b3, Hev b5 and Hev b6.02. chemical residues, MPXX™. The MPXX™ technology levels. This enables you to fight latex allergy Type I reduces the risk of latex allergy Type I and Type IV to a and IV and therefore improves our public health and CHEMIC ALS maximum. occupational safety. HOWEVER, there are two types of allergies related to process. The main advantage of MPXX™ is that anaphylaxis, a condition in which there is a severe The symptoms of Type IV allergy include red itchy scaly rash, often localised to the area of use, i.e. wrists and forearms, but which may spread to other areas. natural rubber latex: Type I caused by the proteins; Gloves can also cause irritant contact dermatitis. This With the main aim of preventing contamination Cleantexx - MPXX™ gloves are the highest quality Type IV caused by chemical residue, mostly coming is however not a true allergy. A choice of a good glove between care-givers and patients, today’s medical available in the industry and meet the international from accelerators that are used to convert the raw and the correct use are in this respect important. gloves are made of several different materials like NRL, requirements of ASTM International, the European material to a usable item. The chemicals that most nitrile and vinyl, powdered or unpowdered. Standard EN 455, part 1 – 3 and other equivalent likely cause a reaction are thiurams, dithiocarbamates international standards. Besides fulfilling all and mercaptobenzothiazoles. Type IV allergy is also Due to the risk of latex allergy Type I cases alternative requirements under these standards, Cleantexx - known as allergic contact dermatitis. materials like nitrile and vinyl have become widely MPXX™ gloves have been subjected to the most used. However, they lack the expected tactility and comprehensive combination of test methods available, dexterity and they cause in a number of cases latex including extensive user tests. allergy Type IV, known as allergic contact dermatitis, due to the chemical residue of substances used in the Cleantexx - MPXX™ gloves are the solution to rising production process. healthcare expenses and budget constraints. The solution is the NRL Cleantexx - MPXX™ Cleantexx - MPXX™ gloves are available in two types, examination glove. Cleantexx Premium (non-grip) and Cleantexx Classic (grip). Did you know that... Although Type I allergy does not occur in response to alternative materials like nitrile due to the absence of proteins, this material typically contains the same chemical residue (MBT) that can cause serious Type IV allergy (allergic contact dermatitis). This is a career-threatening issue and can cause the loss of valuable Healthcare staff. It could be difficult to find an alternative glove once the allergen has been identified. It is therefore important to source a glove that is considered clean, evidenced by various available test methods. Secure & clean product Cleantexx - MPXX™ gloves are sourced from Latexx Latexx Partners Bhd started its operation in 1988 and Partners Bhd, located in Kamunting Industrial Estate, is today one of the global largest medical examination north of peninsular Malaysia, with close proximity gloves producers in the world. Actually, it is presently to Penang seaport and Penang international airport. the largest glove manufacturing company with all Thanks to Total Glove’s set-up we are able to carry out its factories built in one single site. The company outstanding research, executed by highly qualified embarked on an aggressive expansion plan. By 2013, staff in state-of-the-art laboratories. Besides the a target of 12 billion gloves is set. And, by year 2015 a application of the MPXX™ technology, much of our capacity target of 15 billion gloves per annum should research is focused on product development and plant be achieved. technology improvements. Our result-driven research efforts have made it possible to manufacture MPXX™ PXX™ As part of our total customer satisfaction approach, Cleantexx - MPXX TM gloves were tested with various users (medical staff). One of the conclusions is that Cleantexx - MPXX TM gloves score significantly better than regular gloves. CLE ANTE X X – MPX X ™ GLOVES ARE A P P R E C I AT E D M O R E T H A N R E G U L A R G L O V E S treated examination gloves with th the best protective In line with our commitment to quality, we pledge to serve both internal and external customers, based on the following commitments: • No compromise on the quality of incoming raw materials IMPORTANCE features, leading ing to maximum customer satisfaction. n Ease to put on g Comfort when wearing Sense of touch Strength of glove Fit Grip Ease to take off • Total customer satisfaction. • Strive to make our products even safer and more reliable through continuous improvement. check-points • Quality assurance performed at specific check-poin nts Grip when using wet instruments Wave 1 Smell Wave 2 Colour Wave 3 Colour change like Incoming Material Inspections, Process Quality Regular 0% Control, In-process Lot Inspection and Pre-shipmen Pre-shipment nt 20% 40% 60% 80% 100% Inspection. AF TER THREE WEEK S OF USE, CLEANTEX X – MPX X™ IMPORTANCE G L O V E S S C O R E S I G N I F I C A N T LY B E T T E R T H A N R E G U L A R G L O V E S Ease to put on Sense of touch Fit Ease to take off Smell Colour change 0% Cleantexx 20% 40% Source: Skim Market Research 60% 80% 100% Regular Test results Overview CLEANTEX X PREMIUM (NON - GRIP) C L E A N T E X X C L A S S I C (G R I P ) THICKNESS (SINGLE WALL) • Unquantifiable protein Cuff (at 25 mm from cuff end) • Undetectable chemical residue Palm (at centre of palm) min. 0.12 • Natural Rubber Latex Finger (at 13 mm from the extreme tip) min. 0.15 LOCATION OF THICKNESS MEASUREMENT SINGLE WALL THICKNESS (mm) Besides complying with the standard requirements under the ASTM International and EN 455 standards, Cleantexx – MPXX™ gloves are constantly subjected to a variety of tests, ensuring the highest quality available for the environment, the user and avoidance of latex allergy Type I and Type IV. All tests are executed with well respected international accredited laboratories. min. 0.10 TEST RESULTS INTERNATIONAL STANDARD CLEANTEXX GLOVES Modified Lowry EN 455-3 ASTM D5712 Not detected Eliza inhibition test antigenic protein ASTM D6499 Not detected RAST inhibition EN 455-3 Not detected Amino acid analysis by High Pressure Liquid Chromatography (HPLC) EN 455-3 Not detected FITkit ASTM D7427 Unquantifiable • Non-sterile • Single use • Biodegradable • Easy donning PALM WIDTH AND LENGTH • Ambidextrous • Beaded cuff • Powder free PROTEIN LEVEL Leachable protein levels comply with EN 455-3 and ASTM D5712 ASTM D7427 Hev b1, Hev b3, Hev b5 and Hev b6.02 Unquantifiable SIZE PALM WIDTH (mm) LENGTH (in mm) X-small 75 ± 5 min. 240 Small 85 ± 5 min. 240 Medium 95 ± 5 min. 240 Large 106 ± 5 min. 240 X-large min. 110 min. 240 TENSILE PROPERTIES CHARACTERISTICS REFERENCE STANDARD BEFORE AGING AFTER AGING 7 DAYS @ 70 ºC ± 2 HOURS Tensile Strength (MPa) ASTM D3578 min. 18 min. 14 Ultimate Elongation (%) ASTM D3578 min. 650 min. 500 Force at Break (N) EN 455, part 2 No protein bands or the molecular weight markers have been observed SDS-Page* EN 1186-3:2002 EN 1186-14:2002 Overall migration Primary skin irritation Non-irritant Chemical permeation (PPE) EN 374-1/3 5 out of 12 chemicals Chemical residue MRB in house Not detected Cytotoxicity MTT ASSAY ISO 10993:5 Pass Barrier defect ASTM D5151 AQL 1.5 Migratable N-Nitrosamines EC 1935/2004 Pass All tests were executed by international accredited test institutions and the results are available upon your our specific request. * On the washing fluid. ≥6 Did you know that... EN 455 455,, 1-3 1-3 Not detected or below permissible limit Undetectable levels of chemical residue in the Cleantexx MPXXTM gloves enhances biocompatibility and strongly reduces Type IV allergy risk. Budev BV Bloemendaalseweg 139 2061 CH Bloemendaal The Netherlands T: +31 (0) 23 525 50 74 [email protected] www.budev.com EN 455, 1-3