Optical Component Measuring Systems
Transcription
Optical Component Measuring Systems
Optical Component Measuring Instruments 〉〉〉 Ferrule Concentricity Measuring Instrument Static-Pressure Air Bearing Centripetal Method Achieves High Precision ● Core ACCRETECH air technology used to develop new method that achieves measuring accuracy of 0.1μm (patent pending). High Throughput: Six Second Measurements! ● A new method where the ferrule is not rotated enables unprecedented measuring speed (3 sec. measurement + 3 sec. loading/unloading). Easy Operation with LCD Touch Panel ● The LCD touch panel can be used on the production floor. ● Judgment conditions/system conditions can be tailored to individual users. ● Maintenance function facilitates management of system accuracy. Standard Workpiece Loading/Unloading Device Optical Component Measuring Systems Robot transfer type 288 ■ Differences in Ferrule Holding Methods ACCRETECH Method Conventional Method Ferrule Drive roller Ferrule Hole Air V stand ● Subject to influence of contaminants (V stand, rotation roller and ferrule must be cleaned). ● Defective component of outer diameter profile is included in measured value since two points on outer diameter are used as reference, preventing the eccentricity and shape defect from being separated. ● Measuring accuracy deteriorates due to wear of V stand (management of V stand required). ● Centripetal holding of ferrule outer diameter reference with static-pressure air bearings. ● Not subject to influence from external contaminants or shape defects. ● Outer diameter measured can be performed (measurement of bearing back pressure). ● Contact is minimal when the item is inserted and removed, minimizing wear. Specifications FCM-5000A Model φ1.25mm and φ2.5mm (by changing measuring head) Applicable ferrules Concentricity, inner diameter, outer diameter Measuring items Measuring method Measuring accuracy Concentricity/inner diameter Optical microscope Outer diameter Static-pressure air bearing centripetal method (* patent pending) Concentricity ±0.1μm or less/2σ (Resolution: 0.01μm) Inner diameter ±0.1μm or less/2σ (Resolution: 0.01μm) Outer diameter ±0.1μm or less/2σ (Resolution: 0.01μm) Transfer device Select part feeder or robot Power source Single phase AC 100V ±10%, 50/60 Hz Power consumption 1.5 kVA Air source Air supply: 0.4 MPa, Consumption: 100R/min, Clean/dry air Installation dimensions 1250 (W) × 650 (D) × 1650 (H) mm: Part feeder type 1360 (W) × 650 (D) × 1650 (H) mm: Robot transfer type Weight 450 kg Optical Component Measuring Systems Parts feeder type 289 Optical Component Measuring Instruments 〉〉〉 Optical Connector End Face Auto Flaw Inspection Instrument Fastest Measuring Time of 2.5 Seconds Defects can be judged in an amazing 2.5 seconds, including auto focusing. High Sensitivity/High Resolution Defect Recognition Even defects where the brightness difference is minimal and very fine detects can be recognized. High magnification display Two Optical Systems The provision of two optical systems (one with high magnification and one with low magnification) enables observation of the surface cladding periphery to the overall connector end face. Easy to Use/Various Analysis Functions Measuring and changing of magnification on the CEI1000A can be performed by touching a single button, and it has a host of analysis functions. Low magnification display Optical Component Measuring Systems 290 ■ Features ■ Windows 2000 Based ■ Cursor Display Function The adoption of Windows 2000 provides a stable operating environment A line cursor can be superimposed on the image and freely moved, facili- and high compatibility with other computers. In addition, the user inter- tating detailed analysis of flaw dimensions. face for the analysis software complies with the Windows user interface protocol, allowing the program to be used with icon and the tool bar. ■ Filing Function In addition to measured data, image data can be displayed in bit map for- ■ Easy to View Analysis Screen mat and analysis results can be stored in text file format. Displayed An easy to view screen display format is provided for OK/NG judgment images and analysis results can easily be pasted into WORD or EXCEL results, contour display of each defect, display of boundary lines and dis- using the clipboard. play of the size and number of defects in a table. ■ Auto Store Function ■ Auto Focus Function The measured results can be automatically stored without individually The high-speed focus function quickly focuses on the surface cladding storing them. The auto store setting can be set to only store the values when performing high-magnification observation. for NG judgments. ■ Image/Result Print Function ■ Customize Functions The analysis results and images can be printed in three different easy-to- The CEI-1000A has a host of customize functions, including flaw number view layouts. display existence, color setting for zone boundary line and image contour ■ Video Display Function The connector end face can be observed live on the screen. ■ Zoom Function A digital zoom function is provided that enables the displayed image to enhancement. ■ System Manager Mode The various settings are protected so that cannot be easily changed. The proper password must be entered to activate the system manager mode in order to change settings. be magnified by approximately 2,000 times. The screen layout can be changed to display the entire image on the screen. ■ Judgment Reference Setting Function The analysis range and judgment reference can be freely set according to the requirements of different standards or independent user standards. The set standard can be stored and read. Specifications CEI-1000A Model Measuring principle Optical microscope Inspection mode High magnification Low magnification Display magnification Approx. 800 times Approx. 50 times (max.) (Approx. 2000 times) (Approx. 150 times) Flaw detect function Auto detect Visual inspection Applicable connectors SC/MU Operating system Windows 2000 Measuring items Surface flaws, dents, chipping, – pin holes, chips, dirt, adherence of minute particles, chips or dirt epoxy material Processing functions Auto focus function – Video display function Print function Cursor display function – Judgment condition setting function – Enlarged display function Auto store function – System manager function Power source Single phase AC 100V ±10%, 50/60 Hz Power consumption 200 VA Unit dimensions Optical Component Measuring Systems on boundary line, any extruding 401 (W) × 415 (D) × 214 (H) mm (excluding personal computer) Weight Approx. 20 kg * This product was jointly developed with NTT Advanced Technology Corporation. 291 Optical Component Measuring Instruments 〉〉〉 (patent pending) Ferrule Inner Diameter Automatic Measuring Instrument Dramatically Reduced Operating Costs Operating costs are dramatically lower on the MHM-2002A since the air measuring technology it incorporates does not require the expensive consumables used with pin-gauge based automatic measuring instruments. Mastering screen Multi-point sensitivity calibration has been adopted, minimizing detector error with pin gauges. 125.8 125.6 125.4 Cycles Back pressure measuring method This method achieves high repeatability. Specifications ●Measuring Unit MHM-2000A Model Inner diameter: φ0.125mm Applicable Outer diameter: φ1.25mm and φ2.5mm workpieces (by changing measuring unit part) Height: 6.5 – 20 mm Optical Component Measuring Systems 292 Measuring principle Back pressure measuring method Measuring accuracy 0.1μm or less / 2±σ (repeatability) Resolution 0.01 μm Cycle time 5 seconds/piece Measuring unit 950 (W) × 700 (D) × 1600 (H) mm dimensions (not including signal tower) Power source AC 200V, 50 Hz, 3 phase Air source 0.5 – 0.8 MPa ●Control Unit E-PV10 Model Display 6.4 inch TFT color LCD Display items Measured results Resolution 0.01 μm Display unit Select μm, mm or inch No. of detectors 4 Input method Touch panel and sheet keys Magnification calibration Measuring condition setting Key input or auto master Key operation after PC card is inserted 25 22 19 16 13 125.0 10 125.2 7 5 Second Cycle Time Repeatability 126.0 4 Indicated value (μm) A high measuring precision of 0.1μm/±2σ (repeatability) has been achieved. Measured workpieces can be accurately classified (five standard classes). 1 High Precision Measurement Ferrule Automatic Sizing Device 〉〉〉 Ferrule Automatic Sizing Device High Precision A high accuracy of 0.2μm is achieved with a compact, highprecision measuring head (MINI-Σ). In-Line Roundness (option) Roundness can be measured for all items in-line (V10 optional function). All Air Type The entire drive system is air powered by combining the unit with an air drive unit, eliminating the necessity of a hydraulic source. Sample ferrule outer diameter measurement PULCOM MINI Σ-V + PULCOM V10 (V7 or U400 can also be used) ■ Outer Appearance/ Dimension Diagram Specifications Configuration 89 Outer diameter sizing 0.2 μm Applicable workpieces φ1.25, φ2.5 Drive unit Air drive unit: 0.3 – 0.5 MPa Retract Air retract: 0.35 – 0.5 MPa Min. resolution 0.1 or 0.01 μm MODEL E-TV SERIAL 80 139 (178.12) 0.7 φ 2.5 (0.4) Optical Component Measuring Systems 177.5 PULCOM V10 + MINI Σ -V + Air Accuracy (repeatability) 190 End face sizing 293