Brochure HRO 4 Axeon 800615
Transcription
Brochure HRO 4 Axeon 800615
HRO 4-Series Membrane Systems The Hellenbrand HRO4-Series Membrane Systems are state-of-the-art, versatile systems for treating municipal and brackish water supplies and with flow rates ranging from 500 to 8,000 gallons per day. Minimal energy consumption, low maintenance and operation costs make the HRO 4-Series reverse osmosis systems the right choice. Big on features but not on space, HRO 4-Series Systems feature a robust, innovative design that allows for versatility in the event of feed water quality and temperature variations. A C21 or C23 controller with feed flush comes standard to reliably operate the system. HF4-Series Extra Low Energy membranes are standard on all systems and offer high rejection and flow rates for quality system performance. Systems also feature a heavy duty 1/2 HP or 1 HP stainless steel multistage booster pump for superior performance and corrosion resistance. Features C21 or C23 Switch Controller with Feed Flush Extra Low Energy Membrane Elements Fiberglass Membrane Housings 4.5” x 20” Single O-Ring Pre-Filter Housing 5 Micron Sediment Pre-Filter Multistage Stainless Steel Centrifugal Pump Motor Thermal Overload Protection Pump Operating Pressure Gauge Pre-Filter In Pressure Gauge Pre-Filter Out Pressure Gauge Permeate Flow Meter Concentrate Flow Meter Concentrate Recyle Flow Meter Feed Low Pressure Switch ASCO Solenoid Valve Stainless Steel Concentrate Valve Stainless Steel Recycle Valve Chemical Injection Port and Plug Rubber Bumper Kit HRO 4-4000 Membrane System Shown with Standard C23 Controller Options C23 Controller (500 GPD and 1000 GPD) Membrane Expansion Kit (6000 GPD to 8000 GPD) C asters Levelers TDS Meter HRO 4-Series Membrane Systems Product Specifica tions HRO 4-500 HRO 4-1000 HRO 4-2000 HRO 4-4000 HRO 4-6000 HRO 4-8000 Design Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Feed Water Source TDS <2 , 0 0 0 TDS <2 , 0 0 0 TDS <2 , 0 0 0 TDS <2 , 0 0 0 TDS <2 , 0 0 0 TDS <2 ,0 0 0 System Recovery * 50% - 75% 50% - 75% 50% - 75% 50% - 75% 50% - 75% 50% - 75% Rejection a nd Flow Ra tes N ominal Salt Rejection Permeate Flow Rate* Concentrate Flow Rate (min.) Concentrate Recycle Flow Rate 99% 99% 99% 99% 99% 99% 0 . 3 4 gpm 0 . 6 9 gpm 1 . 3 9 gpm 2 . 7 8 gpm 4 . 1 7 gpm 5 .5 6 gpm 1 . 0 0 gpm 1 . 0 0 gpm 1 . 0 0 gpm 3 . 0 0 gpm 3 . 0 0 gpm 3 .0 0 gpm Up to 1 . 0 0 gpm Up to 1 . 0 0 gpm Up to 2 . 0 0 gpm Up to 5 . 0 0 gpm Up to 5 . 0 0 gpm Up to 5 .0 0 gpm Connections Feed Connection ¾ ” FN PT ¾ ” FN PT ¾ ” FN PT ¾ ” FN PT ¾ ” FN PT ¾ ” FN PT Permeate Connection ½ ” MN PT ½ ” MN PT ½ ” MN PT ½ ” MN PT ½ ” MN PT 1 ” MN PT Concentrate Connection ½ ” MN PT ½ ” MN PT ½ ” MN PT ½ ” MN PT ½ ” MN PT ½ ” MN PT Membranes Per Vessel 1 1 1 1 1 Membrane Quantity 2 3 3 2 3 2521 2521 2540 4040 4040 4040 1:1 1:1:1 1:1:1 1:1 1:1:1 1 :1 :1 :1 2 3 3 Membra nes Membrane Size 1 4 Vessels Vessel Array Vessel Quantity 2 3 4 Pumps Multi-Stage Multi-Stage Multi-Stage Multi-Stage Multi-Stage Multi-Stage Motor HP ½ HP ½ HP ½ HP ½ HP 1 HP 1 HP RPM @ 60 HZ 3450 3450 3450 3450 3450 3450 110V 1PH 60Hz 110V 1PH 60Hz 110V 1PH 60Hz 110V 1PH 60Hz 220V 1PH 60Hz 220V 1PH 60Hz 18” x 18” x 45” 18” x 18” x 45” 18” x 18” x 45” 18” x 18” x 45” 18” x 18” x 45” 1 0 5 lbs. 1 1 0 lbs. 1 2 0 lbs. 1 4 0 lbs. 1 6 0 lbs. Pump Type Electrica l Standard Voltage System Dimensions Approx. Dimensions (L x W x H) 1 8 ” x 1 8 ” x 4 5 ” Approx. Weight 1 0 0 lbs. * Product flow and recovery rates are based on feedwater condition of 1000 ppm TDS at 77°F. Treatment ability of the RO System is dependent on feed water quality. Higher TDS and/or lower temperatures will reduce product flow. Performance projections should be run for each installation. Operating Limits Design Temperature 7 7 °F Max. Turbidity N TU ^ 1 Max. Feed Temperature 8 5 °F Max. Free C hlorine ppm 0 Min. Feed Temperature 4 0 °F Max. TDS ppm 1 2 0 °F Min. Ambient Temperature 4 0 °F Max. pH (C ontinuous) Max. Feed Pressure psi 85 Min. pH (C ontinuous) Min. Feed Pressure psi 45 Max. pH (C leaning 3 0 Min.) 12 200 Min. pH (C leaning 3 0 Min.) 2 Max. O perating Pressure psi Max. Hardness G PG ^^ 2,000 Max. Ambient Temperature 0 11 3 <3 Max. SDI Rating Test Pa ra meters: Static pressure test for 5 minutes. ^ Appropriate filtration must be installed in order to prevent premature membrane fouling. ^^ Scale prevention measures must be taken to prolong membrane life. P: 608-849-3050 404 Moravian Valley Rd, Waunakee, WI 53597 MKTF-349 M KTF-3 4 4 08/ 14 ©2014