aerothermie - Jurapac Pompes à chaleur
Transcription
aerothermie - Jurapac Pompes à chaleur
AEROTHERMIE LE PRODUIT MODELE 2014 10 KW 15 KW 20 KW 25 KW MONOBLOC BIBLOC MODELE 2014 COMPRESSOR EVI R407C INJECTION VAPEUR Kapillare + INJECTION LIQUIDE ENVELOPPE DE TRAVAIL PUISSANCE CALORIFIQUE : + 25% COP : + 10% VENTILATEUR EC ZIEHL ABEGG DEBIT AIR 100 % 50 % 25 % AC X dB -3 db -6 dB EC X dB -15 dB -30 dB DÉTENTE : EEV SIEMENS AUTRES FOURNISSEURS : Danfoss, Swep, Emerson, HTS,……. CHOIX ET DIMENSIONNEMENT DE LA POMPE A CHALEUR 1.- MARCHE DE LA RENOVATION 1.1 BESOIN EN CHALEUR DE LA MAISON A CHAUFFER OU CONSTRUCTION AVANT 1980 …..> 100-120 W/m2 CONSTRUCTION ENTRE 1980 ET 1994 …….> 80 W/m2 1.2- DETERMINATION DE LA TEMPERATURE ALLER NECESSAIRE A) LE BESOIN EN CHALEUR DE CHAQUE PIECE EST CONNU B) CALCUL EXPERIMENTAL EXEMPLE 2.- NOUVELLES INSTALLATIONS DE CHAUFFAGE 3.- BESOIN SUPPLEMENTAIRE EN PUISSANCE COUPURES DES SOCIETES DE PRODUCTION EAU CHAUDE SANITAIRE 0,2 KW par personne DETERMINATION DE LA PUISSANCE DE LA POMPE A CHALEUR EXEMPLE 55°C Température de sortie d'eau 20 45°C Courbes de Puissance 10 ASX 35°C 18 16 Puissance ( kW ) 14 12 10 Puissance calorifique * 8 6 Besoin en chaleur du bâtiment lié a la température extérieure 4 2 0 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 Température extérieure ( °C ) 8 10 12 14 16 * sans dégivrage 18 SIEMENS RVS ECS The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. Ballon The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still Solaire Piscine The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. fireplace, boiler PAC The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. RVS63 Siemens RVS The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. BUS The image cannot be displayed. Your computer may not have enough memory to open the image, or The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, The image cannot be displayed. Your and then open the file computer may not have enough memory again. Ifto the red x still open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. Chauffage et refroidissement external control systems (inteligent house) Recuperation HP Product range overview Complete range of goods Modbus & LPB interface Commissioning & Service tool GSM Web-server Room units wired & wireless Enhanced Vapour Injection (EVI) HMI AVS… Electronic Expansion Valve (EEV) Temperature Sensors NTC10Kohm Controls RVS… Flow meters Pressures sensors SIEMENS SYSTEM CONFIGURATION ENTREES ET SORTIES Qx Hx X86 1 X84 M BX4 M BX3 1 GX1 H3 M H1 G+ M BSB AVS55.199 X11 1 X10 1 X86 RVS21.826/xxx Bx Hx M DI7 DI6 M UX3 D3 D2 D1 X100 Bx M UX 2 M UX 1 M BX2 M BX 1 Wx 1 1 1 X 80 Ux Bx X 75 X 70 X 50 L X12 1 N X15 EX4 EX3 EX2 EX1 QX3 FX3 N QX2 QX2 N QX1 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. Ex N ZX6 N QX5 N QX4 QX4 Qx X 30 X 60 CONFIGURATION ENTREES ET SORTIES Qx Ex Hx AVS55.199 RVS61.843/xxx RVS21.826/xxx Bx Ux Bx Hx DETAIL CONFIGURATION ENTREES ET SORTIES 230V inputs EX1…EXx Relay outputs QX1…QXx Digital/ analogue inputs H1, H2, H3 Sensor inputs BX1… BXx Analogue output UX PA G E 3 1 CONFIGURATION PAR SONDES DE TEMPERATURES Schema partiel PAC, Vanne melangeuse, buffer and DHW are needed: Which sensors required to be configured and connected for activation of the functions? Q9 B9 Q3 Y1/Y2 B21 B4 K1/E11 E9 P B1 B81E10 P B3 E15 B83 B91 Q8/E14 Q2 B41 B92 B71 Partial diagram Heat pump Partial diagram DHW Partial diagram buffer Partial diagram heating circuit Application configuration Wide range of applications Ballons Q11 ECS Distributions B3/B31 B4 B4 Tauscher1 0 Solar B36 Q11 2358A37 Mazout / Gaz 1 B42 B41 Q3 T B4 B3 B3 B6 Tauscher1 Solar Solaire B3/B31 B31 2358A37 0 1 B31 Q33 B3 T B3 B31 K8 B63 B4 B39 B38 B2 B64 UX Y17/Y18 K4 B31 Q5 T B31 B41KW B3 T B4 Q34 B6 B13 B41KW B4 T K8 K9 Tauscher1 Solar PAC B2 T Q5 K5 K4 Siemens HVAC library B42 B41 Q15/Q18/Q19 SCHEMA 10 SCHEMA 11 SCHEMA 12 SCHEMA 13 SCHEMA 14 SCHEMA 15 SCHEMA 16 ECS Schema hydraulique recommande ‣ Avec ou sans solaire ‣ DHW IMPORTANT: 0.25 m2 par kw BUFFER tank-in-tank solution ECS Chauffage ECS instantanée Echangeur a plaques extérieur Pompe de circulation modulable COMPLEMENT NON Sonde de temperature manquante OUI Integration du chauffe eau électrique NON OUI Clapet de retour PROGRAMMATION VIA PC Service Tools: OCI700.1 PROGRAMMATION PAR INTERNET WEBSERVER OZW672 § OZS164 § (SMS) § OZW672 RVS LPB/BSB Ethernet USB OZW672 Alarm SMS § Verze § OZW672.04 ... 1 device § OZW672.04 ... 4 device § OZW672.16 ... 16 device GSM1) Alarm Email Internet § § § § Local over USB Local over Internet Remote over internet Remote over GSM1) (only OZS164 version)