Using Measured Solutions for Cost Savings — Lyoid Fussell

Transcription

Using Measured Solutions for Cost Savings — Lyoid Fussell
Using Measured Solutions
For Cost Savings
Presented By: Lyoid Fussell
MEASURED SOLUTIONS
Outline
• What Are Measured Solutions?
–
–
–
–
SpectraStim – Radioactive Tracer
SpectraChem – Chemical Tracer
SpectraScan – Radioactive Tracer Analysis
Completion Profiler – Production Profiling
• How Can Measured Solutions Cut Costs?
– No Pay Left Behind
– No Pay Compromised
– Analyzing Techniques and Methods to Find What Works
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
SpectraStim
• ZeroWash Tracer
– Ir-192
•
74 Day Half Life
– SC-46
•
83.8 Day Half Life
– Sb-124
•
60.2 Day Half Life
• Two Types
– ZW – Crush Strength > 8,000 PSI – 40/70 Mesh
•
2.65 Specific Gravity
– ZWLD – Crush Strength 1,500 – 2,000 PSI – 40/70 Mesh
•
1.3 – 1.48 Specific Gravity
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
SpectraChem
•
14 Uniquely Identifiable Chemical Tracers
–
–
–
–
–
Can be injected individually in multiple stages.
Can be injected in various segments of single stages.
Flowback analysis quantifies load recovery and stages contributing to flowback.
Analysis performed using gas chromatography and mass spectrometry.
Also perform Ion analysis to quantify chlorides.
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
•Full Spectroscopy Memory
Tool
•Can be ran on SlickLine,
Wireline, Coiled Tubing and
Tractor
•Records the Entire Energy
Spectrum of Natural and
Injected Gamma Emitting
Isotopes.
Did You Know?
What Went Right?
Pad
DV Tool
(4700' Uphole)
Excessive Uncontained
Frac Height
Proppant
Mechanical
Failure
Perforations
Cement
Channel
Target Zone
Stage Isolation
Failure
Frac Height
Containment
Stg 2
Squeeze
Perforations
Stg 1
Stage 2
Bridge Plug
Intended Pay
Stage 1
Perforated Out
Of Zone
Early Proppant
Perforation
Effectiveness
Late Proppant
Proppant
Flowback
Collar Locator
Indicates Actual
Perforations
Downhole
Video Revealed
no Perforation
Intended Perforations
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Limited Entry Example – Does It Work?
Ran Ir-192 Prior To Ball Drop
Ran Sc-46 After Ball Drop
Balls Created No Diversion
We know what’s left behind, how do we get it?
Next job pumped in two separate Stages.
MR 1H – 7-Stg Cemented Horizontal
7 Stage Cemented Horizontal – Well A
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
MR 5H – 6-Stg Cemented Horizontal
6 Stage Cemented Horizontal – Well B
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
MR 1H
2 1000’ Parallel Offsets – Same Stage Volumes
MR 5H
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
CONCLUSION
• Using measured solutions you can ensure no pay is left
behind, and your stimulation strategies are working.
• Post job analysis takes on a new meaning allowing you to
analyze what went right and clearly identify what went
wrong.
• You may be able to, use less expensive completion
techniques, downsize job volumes, treat larger intervals,
and isolate water and production issues.
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
CONTACT INFORMATION
LYOID FUSSELL
(918) 760-7775
[email protected]
http://www.corelab.com/pe/protechnics/
THANK YOU!
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Frac Height Containment
Did you know that fracture
height growth was
contained?
Squeeze
Perforations
RESULT: Lost reserves
due to unstimulated pay
Intended Pay
ACTION: Isolate lower
perforations, perforate
missed pay and re-frac
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Cement Channel
Did you know that the
cement job didn't isolate the
formation?
RESULT: Ineffective
stimulation of target
interval
ACTION: Squeeze and
restimulate
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Pad
Did you know that there
was extensive downward
frac growth?
Proppant
Excessive Uncontained Frac Height
RESULT: Ineffective
stimulation with shorter
than planned frac length
Perforations
ACTION: Use tracer data
to recalibrate 3D frac
model for the next well
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Mechanical Failure
Did you know that the frac
went through an uphole DV
tool?
DV Tool
(4700' Uphole)
RESULT: Ineffective
stimulation of intended pay
zone
ACTION: Refrac the well
down-tubing
BACK
Target Zone
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Perforated Out of Zone
Did you know the
perforations were shot off
depth?
RESULT: The reservoir
never had a chance to
perform
ACTION: Squeeze,
re-perforte on depth and
re-frac the target zone
BACK
Collar Locator
Indicates
Actual
Perforations
Intended
Perforations
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Perforation Effectiveness
Did you know that the lower
perforations did not treat due
to ineffective perforating?
RESULT: Bypassed
reserves
ACTION: Improve
perforation QA/QC
Downhole
Video
Revealed no
Perforation
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
RESULT: Damaged
connection to the wellbore
resulting in decreased
production potential
Early Proppant
Did you know that the
wellbore connection flowed
back?
Late Proppant
Proppant Flowback
ACTION: Refrac the well
down-tubing
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
Stage Isolation Failure
Did you know that the stage
isolation device failed during
pumping of Stage 2?
Stg 2
Stg 1
Stage 2
RESULT: Ineffective
stimulation of Stage 2 and
possible damage to Stage 1
fracture
Bridge Plug
Stage 1
ACTION: Re-frac Stage 2
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY
BACK
MEASURED SOLUTIONS
THE COMPLETION DIAGNOSTICS COMPANY