MobiCAN - temp.sie.de

Transcription

MobiCAN - temp.sie.de
MobiCAN
Mobile Network Diagnostics
MobiCAN
Overview/Key Features
-
Quick visualization of CAN-Daten
-
Powerful and energy-saving processor
-
Various communication interfaces
-
Accumulator for mobile deployment
-
Compact housing for intensive usage
MobiCAN – Fieldbus diagnostics and visualization
MobiCAN is a small industrial PC that has been designed for diagnostics in 11-Bit or 29-Bit identifier CANBus networks. It is capable of providing CAN-bus system monitoring as well as analysis of layer 7 protocols
such as CANopen or SAE J1939. Following that, MobiCAN allows a user-friendly overview about CAN nodes
and their specifications as well as preparing and sending data frames. Recorded data can easily be modified
before being sent over the CAN-bus. The mobile terminal may also contain the Sontheim CANexplorer 4
field bus diagnostic software as a high-performance developer’s tool.
Technical Data
The CPU is an Intel® Atom™ microprocessor and offers very little energy consumption combined with high
computing power. There are 512 MByte DDR2 RAM as well as a Solid State Drive with 512 MByte and a SD
slot implemented. The operating system can be stored on the SSD, whereas applications can be stored and
carried out on either SSD or SD-card. In order to have as much display space as possible available for
diagnostic applications, the mobile terminal uses a resistive 7” touch display with room for softkeys at the
two outer verges.
Interfaces And CAN Features
The connection to different field bus
networks is realized via CAN interface with
one male and one female M12 connectors.
Sontheim has put emphasis on a sophisticated
CAN interface, housing many features for
engineering purposes. CAN-data traffic is
controlled by a 32 Bit ARM7 microcontroller.
The integrated error frame detection is used for detecting error messages
and forwarding them to the host system. By periodically measuring CANHigh and CAN-Low levels, the user has another indicator for the status of
the CAN network. Finally, MobiCAN conducts a power metering via CANHigh.
There are two USB 2.0 interfaces for connecting external peripherals like
mouse, keyboard or memory stick. Another M12 connector is used for
realizing an Ethernet port. It has a bandwidth of 100 MBit for its
connection to a network or direct data transfer.
Maximum Usability Via Intelligent Power Supply And Ergonomical
Design
Besides its computing power for field bus diagnostics, MobiCAN offers various features that greatly
enhance its operating fields and user-friendliness for service technicians. When being mounted in a fixed
place, power supply of 10 to 32 V is done via CAN-connectors. However, personnel that are in daily routine
will appreciate the possibility to bypass the way from one diagnostic task to the next with a buffer
accumulator and their car power supply, which also fits to the MobiCAN.
The housing provides an ergonomical design along with a pressure compensation element. All interfaces are
designed in a way that no water can accidentally enter the inner workings. In summary, MobiCAN achieves an
IP-class 62 and state-of-the-art power consumption figures due to Atom™ technology, LED-backlight, SSD, SD
etc..
Numerous processes – one single solution
The standard procedures of doing field bus diagnostics are widespread: Whereas some processes need
constant monitoring and maintenance at only one single location, a service technician already needs the
flexibility of connecting and disconnecting the diagnostic device as well as different features like a rigid and
compact design, many possibilities for data transmission etc.
However, the most difficult task is to guarantee both a wide range of functions and a great amount of
flexibility. Only the combination of these characteristics can professionally cover all the applications that
are in between of a sole stationary or a sole flexible use.
A typical application is a bigger machine network with different field bus systems in a tough environment.
With MobiCAN Sontheim Industrie Elektronik achieved the connection of data progression and visualization
in one single device which is a major advantage for handling. Consequently, there are no additional laptops
needed. The accumulator facilitates dismounting and taking it to another machine. This saves costs of
having several diagnostic units for various machines. The design allows a deployment in tougher
environments and guarantees full operational ability even when being often connected and disconnected.
The device can be used for diagnostics in the automation as well as the automotive sector. Another
application might therefore be the reading of CAN-data in a vehicle during a test drive with the MobiCAN
connected to the onboard power supply. It facilitates the easy progression of data. A service technician
therefore doesn’t need to be concerned of spraying water or heat or a loss of power.
Overview
Technical Data
CPU
ATOM 1,1 to 1,6 GHz
RAM
512 MByte to 1 GByte
Data memory
Internal SSD ATA SolidStateDrive flash memory (512MByte to 4 GByte) for the
operating system
Internal SD-Slot with 2GB SD-card for applications and user data
SATA DiskOnModule Flash with up to 16 GByte permanent storage capacity
Supported CAN-interfaces
CANUSB, CANUSBlight, additional interfaces available upon inquiry
Display
7“ WVGA 800 x 480
Touch
Resistive
CAN
2x CAN via 2x M12 Connector (2x female)
USB
2x USB 2.0, interface “A”
Ethernet
1x Ethernet, 100MBit, M12
SD-Slot
Internal, as memory for applications and user data
Keys
3x, On / Off, Display brightness more / less
Direction of interfaces
Downward
Mobile power supply
Integrated NiMH
IP-class
IP62
Power supply
10-32V, via CAN-M12-interfaces
Operating temperature
0…50°C
Storage temperature
-10…60°C
WLAN and Bluetooth
Both functions available on inquiry
Contact us for further information. We are looking forward to your inquiry.
Sontheim Industrie Elektronik GmbH
Georg-Krug-Str. 2
87437 Kempten
Tel: 0831 575 900 0
Fax: 0831 575 900 73
Email: [email protected]