Material KaVo CAM - KaVo. Dental Excellence.
Transcription
Material KaVo CAM - KaVo. Dental Excellence.
Processing instructions Material Processing Instructions for KaVo CAM Systems Always be on the safe side. Manufacturer: Kaltenbach & Voigt GmbH Bismarckring 39 D-88400 Biberach www.kavo.com Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Phone +49 (0) 7351 56-0 Fax +49 (0) 7351 56-1488 Processing instructions Material Processing Instructions for KaVo CAM Systems Table of contents Table of contents 1 User instructions............................................................................................................................................... 4 1.1 User guide................................................................................................................................................ 4 1.1.1 Abbreviations............................................................................................................................... 4 1.1.2 Symbols....................................................................................................................................... 4 1.1.3 Target group................................................................................................................................ 4 1.1.4 Service Hotlines........................................................................................................................... 4 2 Safety............................................................................................................................................................... 5 2.1 Description of safety instructions.............................................................................................................. 2.1.1 Warning symbol........................................................................................................................... 2.1.2 Structure...................................................................................................................................... 2.1.3 Description of hazard levels........................................................................................................ 5 5 5 5 3 Manufacturing (CAM)....................................................................................................................................... 6 3.1 Manufacturing with the KaVo ARCTICA................................................................................................... 3.1.1 Tools............................................................................................................................................ 3.1.2 Procedure for use of the block adapter....................................................................................... 3.1.3 Procedure for use of the GFK/tool holder.................................................................................... 6 6 6 8 3.2 Manufacturing with the KaVo Everest....................................................................................................... 9 3.2.1 Processing of materials "…for KaVo ARCTICA" with KaVo block holder.................................... 9 3.2.2 Circular blank processing.......................................................................................................... 10 4 Procedure/processing outside the CAM process chain.................................................................................. 12 4.1 CAD........................................................................................................................................................ 12 4.2 After CAM............................................................................................................................................... 12 3 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 1 User instructions | 1.1 User guide 1 User instructions 1.1 User guide 1.1.1 Abbreviations Abbre‐ Explanation viation IfU Instructions for use CI Care instructions AI Assembly instructions TI Technician's instructions SC Safety checks IEC International Electrotechnical Commission RI Repair instructions EMC Electromagnetic compatibility PI Processing instructions 1.1.2 Symbols See the Safety/Warning Symbols section Important information for users and technicians CE mark (European Community). A product bearing this mark meets the re‐ quirements of the applicable EU directive. Action required 1.1.3 Target group This document is for dental technicians, dentists, and trained professionals. 1.1.4 Service Hotlines Questions related to the CAD/CAM process chain: KaVo Dental GmbH Service Technical Hotline: Tel. +49 7351 56-2100 [email protected] Application Hotline: Tel. +49 7351 56-2200 [email protected] Questions not related to the CAD/CAM process chain: Homepage/hotline of the manufacturer of the material 4 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 2 Safety | 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions 2.1.1 Warning symbol Warning symbol 2.1.2 Structure DANGER The introduction describes the type and source of the hazard. This section describes potential consequences of non-compliance. ▶ The optional step includes necessary measures for hazard prevention. 2.1.3 Description of hazard levels Safety instructions distinguishing between three hazard levels are used in this docu‐ ment to prevent personal and property damage. CAUTION CAUTION indicates a hazardous situation that can cause damage to property or mild to moder‐ ate injuries. WARNING WARNING indicates a hazardous situation that can lead to serious or fatal injury. DANGER DANGER indicates a maximal hazard due to a situation that can directly cause death or fatal injury. 5 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.1 Manufacturing with the KaVo ARCTICA 3 Manufacturing (CAM) 3.1 Manufacturing with the KaVo ARCTICA 3.1.1 Tools The following tools are available for processing on the KaVo ARCTICA: For the processing of glass-infiltrated ceramics, lithium-silicate ceramics and lithiumdi-silicate ceramics: ▪ Diamond Grinding Pin D0,6 (Mat. no. 1.008.7090) ▪ Diamond Grinding Pin D1 (Mat. no. 1.008.7088) ▪ Diamond Grinding Pin D2 (Mat. no. 1.008.7087) ▪ Diamond Grinding Pin D3,6 (Mat. no. 1.008.7089) For the processing of titanium and plastic materials: ▪ Titanium Milling Pin D1 long shaft (Mat. no. 1.008.7099) ▪ Titanium Milling Pin D0.5 (Mat. no. 1.008.7098) ▪ Titanium Milling Pin D2 (Mat. no. 1.008.7097) ▪ Titanium Milling Pin D1 (Mat. no. 1.008.7096) For the processing of zirconium and C-Temp: ▪ ZS Milling Pin D2 long shaft (Mat. no. 1.008.7095) ▪ ZS Milling Pin D1 long shaft (Mat. no. 1.008.7094) ▪ ZS Milling Pin D1 (Mat. no. 1.008.7093) ▪ ZS Milling Pin D0.5 (Mat. no. 1.008.7092) ▪ ZS Milling Pin D2 (Mat. no. 1.008.7091) Before the manufacturing is started, the system displays which tools are needed for filling an order. 3.1.2 Procedure for use of the block adapter ▶ Insert the block adapter (Mat. no. 1.008.7470) into the tool holder of the KaVo ARCTICA Engine until it reaches the backstop. 6 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.1 Manufacturing with the KaVo ARCTICA ▶ Tighten the threaded pin of the tool holder to the proper torque using the universal tool (Mat. no. 1.009.0859). ▶ Insert the blank into the block adapter until it reaches the backstop. (The installed rotation-securing stop prevents insertion in improper positioning) ▶ Tighten the threaded pin to the proper torque using the universal tool. ▶ After completion of the manufacturing process, undo the threaded pin with the universal tool and take the restoration out of the block adapter. 7 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.1 Manufacturing with the KaVo ARCTICA 3.1.3 Procedure for use of the GFK/tool holder ▶ Insert the GFK holder attached to the blank into the tool holder of the KaVo ARC‐ TICA Engine until it reaches the stop. ▶ Tighten the threaded pin of the tool holder to the proper torque using the universal tool (Mat. no. 1.009.0859). ▶ After completion of the manufacturing process, undo the threaded pin with the universal tool and take the restoration out of the holder. 8 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.2 Manufacturing with the KaVo Everest 3.2 Manufacturing with the KaVo Everest Processing on the KaVo Everest requires the KaVo Everest Cam² software (Mat. no. 1.010.3699). The following tools are available for processing on the KaVo Everest: For the processing of glass-infiltrated ceramics, lithium-silicate ceramics and lithiumdi-silicate ceramics: ▪ Everest® CAM² Grinding Pin 1,3 (Mat. no. 3.000.4624) ▪ Everest® CAM² Grinding Pin 1 (Mat. no. 3.000.4625) ▪ Everest® CAM² Grinding Pin 0.6 (Mat. no. 3.000.4627) For the processing of zirconium and C-Temp: ▪ Everest® CAM² Milling Pin ZS 0,6 (optional) (Mat. no. 3.000.4408) ▪ Everest® Milling Pin ZS 1 (Mat. no. 1.002.8027) ▪ Everest® Milling Pin ZS 1 long (Mat. no. 1.004.8063) ▪ Everest® CAM² Milling Pin ZS 2 (Mat. no. 3.000.4387) ▪ Everest® Milling Pin 3 (Mat. no. 1.001.5999) ▪ Everest® Milling Pin ZS 3 long Mat. no. 1.004.8064 For the processing of titanium and plastic materials: ▪ Everest® CAM² Milling Pin D0,6 (optional) (Mat. no. 3.000.4876) ▪ Everest® Milling Pin 1 (Mat. no. 1.001.5998) ▪ Everest® Milling Pin 3 (Mat. no. 1.001.5999) Before the manufacturing is started, the system displays which tools are needed for filling an order. 3.2.1 Processing of materials "…for KaVo ARCTICA" with KaVo block holder ▶ Clamp the holder gripping yoke into the KaVo Everest (see IfU KaVo Everest CAM²). 9 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.2 Manufacturing with the KaVo Everest ▶ Insert "for KaVo ARCTICA" material into the gripping yoke until it reaches the backstop. (The installed rotation-securing stop prevents insertion in improper positioning) ▶ Tighten the threaded pin of the gripping yoke to the proper torque using the uni‐ versal tool (Mat. no. 1.009.0859). ▶ Please see the software for further instructions for use of the GA KaVo Everest CAM². ▶ After completion of the manufacturing process, take the restoration out of the grip‐ ping yoke. 3.2.2 Circular blank processing ▶ Clamp the circular blank gripping yoke into the KaVo Everest (see IfU KaVo Ever‐ est CAM²). ▶ Check the rubber buffer rings for proper positioning, cleanliness and flexibility. 10 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 3 Manufacturing (CAM) | 3.2 Manufacturing with the KaVo Everest 3.2.2.1 Clamping the circular blank without circular blank gripping ring Note Carefully tighten the screws successively. CAUTION Excessive tightening of the screws on one side can cause the circular blank to break. 3.2.2.2 Clamping the circular blank with circular blank gripping ring Note Carefully tighten the screws successively. CAUTION Excessive tightening of the screws on one side can cause the circular blank to break. ▶ Please see the software for further instructions for use of the GA KaVo Everest CAM². ▶ After completion of the manufacturing process, take the circular blanks off the gripping yoke. 11 / 14 Processing instructions Material Processing Instructions for KaVo CAM Systems 4 Procedure/processing outside the CAM process chain | 4.1 CAD 4 Procedure/processing outside the CAM process chain 4.1 CAD For the material parameters needed for designing the denture, please refer to the pro‐ cessing instructions of the manufacturer of the material or the instructions for use of the CAD software employed in the process. The CAD instructions available from KaVo can be downloaded at http://www.kavo.de/Produkte/CADCAM-Systeme/Downloads/Gebrauchsanweisun‐ gen.aspx . 4.2 After CAM For information on the further processing, please check the homepage or processing instructions of the manufacturer of the material. 12 / 14 1.010.3451 · kb · 20140528 - 1 · en
Similar documents
Processing instructions Everest® G-Blank
1 User instructions ............................................................................................................................................2 1.1 User guide .......................
More informationInstructions for use RONDOflex plus 360
▶ The medical device should be cleaned, serviced and stored in a dry location, ac‐ cording to instructions, before long periods of nonuse. CAUTION Safety checks since cleansers and disinfectants ca...
More information