Small Fragment System

Transcription

Small Fragment System
Small Fragment System. Instruments
and implants for 2.7 mm and 3.5 mm
plate fixation.
Compatible with
DCP, LC-DCP
and LCP Plating
Systems
Cortex, locking
and cancellous
bone screws
Instruments for
standard and
locked plating
Veterinary
Small
Fragment
System
Table of Contents
Introduction
Small Fragment System
2
Product Information
Plates
4
Screws
6
Universal Drill Guides
8
Featured Instruments
910
Set Lists
12
Sterilization Parameters
12
Quick Reference Guide— Instruments
20
Quick Reference Guide— Implants
21
Synthes
Small Fragment System
The Small Fragment Standard System
The Small Fragment Standard System contains the
2.7 mm, 3.5 mm and 4.0 mm implants and related
instruments required for standard compression plating.
Features
– Equipment for LC-DCP and DCP plating systems
– Can be upgraded to LCP system
– Cases are organized in general order of use
– Compact case sizes fit most tabletop autoclaves
– Plate case stores a full range of 2.7 mm, 3.5 mm,
and 3.5 mm Broad DCP, LC-DCP or LCP plates
– Includes auxiliary bins for storing additional equipment
The standard system consists of:
– Small Fragment Standard Instrument Set (103.501),
– Small Fragment Standard Screw Set (103.518)
– Small Fragment DCP Plate Set (103.513)
or
Small Fragment LC-DCP Plate Set (103.514)
The Small Fragment Locking System
The Small Fragment Locking System contains the
2.7 mm and 3.5 mm LCP implants and related
instruments required for locked plating.
Features
– Unique equipment required for LCP plating
– Locking instruments fit in Standard Instrument
Case (690.591)
– All cases are organized in general order of use
– Compact case sizes fit most tabletop autoclaves
The locking system consists of:
– Small Fragment Locking Instrument Set (103.502)
– Small Fragment Locking Screw Set (103.517)
– Small Fragment LCP Plate Set (103.516)
2
Synthes Veterinary Small Fragment System
Synthes
3
Plates
DCP (Dynamic Compression Plate)
DCP plate hole
– Incorporates an incline in the hole that converts screw
compression into plate translation and compression of the
bone fracture
– Accepts conventional screws that may be placed in either
load or neutral positions, depending on whether interfragment compression is desired (see Universal Drill Guide for
more detail)
– Allows 25° of longitudinal screw angulation and 7° of
transverse screw angulation
LC-DCP (Limited Contact Dynamic Compression Plate)
Grooved undersurface
– Provides limited contact between the plate and bone,
minimizing the chance for temporary porosis under the
plate
– Allows periosteal callus formation at the fracture site
Bone loss observed beneath a
full-contact plate
LC-DCP plate hole
– The dynamic compression unit (DCU) hole is symmetrical
and provides bidirectional compression
– Allows 40° of longitudinal screw angulation and 7° of
transverse screw angulation
– Accepts conventional screws that may be placed in either
load or neutral positions, depending on whether interfragment compression is desired (see Universal Drill Guide for
more detail)
Uniform stiffness
– Allows smooth contouring of the plate to the bone
– Protects plate from localized high bending stress, because
of the even distribution of stresses over a long distance
along the plate
LC-DCP
DCP
4
Synthes Veterinary Small Fragment System
Reduced bone loss beneath a
limited-contact plate
LCP (Locking Compression Plate)
– Locking screws create a fixed-angle construct, resulting
in angular stability
– Tapered end for submuscular plate insertion, minimizing
tissue trauma
– Limited-contact plate design reduces plate-to-bone
contact, protecting vascularity
A
B
LCP plate holes
– Dynamic compression unit (DCU) hole allows 40° of
longitudinal screw angulation and 7° of transverse
screw angulation
– Combi holes allow placement of conventional screws
on one side or locking screws on the opposite side of
each hole
A. Threaded hole section for locking screws
B. Dynamic compression unit (DCU) hole section for
conventional screws
C. Locking screw in threaded side of plate hole
D. Cortex screw in compression side of plate hole
E. Stacked Combi hole at plate end accepts either cortex,
cancellous or locking screws
D
C
E
Bibliography
1. Gasser, B., S.M. Perren, and E. Schneider. Parametric Numerical Design
Optimization of Internal Fixation Plates. Transactions of the 7th Meeting.
Aarhus, Denmark: European Society of Biomechanics, 1990.
2. Klaue. K. and S.M. Perren. Unconventional Shapes of the Plate Cross-Section
in Internal Fixation: The Trapezoid Plate. Long Term Study of Bone Reaction in
Sheep Tibiae. Davos, Switzerland: Laboratory for Experimental Surgery, AO/ASIF,
1990.
Synthes
5
Screws
Cortex Screws
– For bicortical fixation in diaphyseal bone
– Self-tapping screws are standard in all sets
– Non-self-tapping screws are also available
Cancellous Bone Screws
– For fixation in poor quality or metaphyseal bone
– Deeper threads and coarser pitch maximizes the surface
area of the threads in contact with the bone, thereby increasing the screw’s holding power in softer bone
Locking Screws
– Use with the Locking Compression Plate (LCP)
– Conical, double-lead machine thread on the head locks
into threaded Combi hole or stacked Combi hole in
the plate
– Create a fixed-angle construct
– Large core diameter provides improved bending and
shear strength
– StarDrive recess provides improved torque transmission
to the screw, while retaining the screw without the use
of a holding sleeve
Screw Reference Chart
Thread Diameter
Screw Type
Drill Bit for
Threaded Hole
Tap
Drive Type
6
2.7 mm
Cortex
2.0 mm
2.7 mm
Locking
2.0 mm
3.5 mm
Cortex
2.5 mm
3.5 mm
Locking
2.8 mm
4.0 mm
Cancellous
2.5 mm
2.7 mm
2.5 mm
Hexagonal
self-tapping
T8
StarDrive
3.5 mm
2.5 mm
Hexagonal
self-tapping
T15
StarDrive
4.0 mm
2.5 mm
Hexagonal
Synthes Veterinary Small Fragment System
Screw Fixation
Bicortical cortex screw fixation is the traditional method of
compressing a plate to the bone. Friction between the plate
and bone maintains stability. Therefore, bicortical screws
require (2) cortices of fixation to achieve stability (Fig. A).
A
Locking screws provide stability and load transfer due to the
threaded connection between the plate and screw. There is
no compression of the plate to the bone.
B
Note: If a combination of a cortex screw and locking screws
is used, a cortex screw should be inserted first to pull plate
to the bone. If a locking screw is used first, care should be
taken to ensure that the plate is held securely to the bone to
avoid spinning of the plate about the bone.
Caution:
Synthes implants and instruments are manufactured with proprietary processes that produce superior products to those created by conventional
manufacturing processes. Though other companies may be able to estimate the Synthes general product design, Synthes product dimensions are
proprietary. The precision design of Synthes products is very important for long-term product function and optimal fit between implants.
Only the finest quality materials are used to manufacture Synthes implants. The metals Synthes uses have been scientifically proven to be of the
best biocompatibility and quality available today.
With these features and qualities, the mixing of Synthes implants with the implants from other companies is not recommended. The overall
performance may be compromised due to differences in design, chemical composition, mechanical properties, and quality.
Given these qualities are trade-secret, no competitor of Synthes can make a genuine claim “the same as Synthes.” Combining implants from
other companies with Synthes implants could reduce product performance. Consequently, it is strongly recommended to not mix parts from
different manufacturers.
Synthes
7
Universal Drill Guides
The universal drill guides are the only drill guides which
function in all Synthes plate holes. When a cortex or cancellous bone screw is used, a universal drill guide should be
used to guide the drill bit. If the screw is intended to achieve
interfragment compression, the universal drill guide should
be placed in the load position, as shown. If the screw is
intended to hold the plate, the universal drill guide should
be placed in the neutral position.
Compression (load) position
Compression is achieved by placing the universal drill guide
in the eccentric position, and maintaining the drill guide
body above the plate as shown.
Compression (load)
8
Synthes Veterinary Small Fragment System
Neutral position
Neutral position is achieved by placing the universal drill
guide in the eccentric position, then compressing the drill
guide body into the hole, which will shift the drill guide
into the neutral position as shown.
Note: For illustrative purposes, a Combi hole has been
depicted. The same methodology applies to LC-DCP and
DCP holes.
Neutral
Synthes
9
Featured Instruments
323.061
2.0 mm Threaded Drill Guide with
Depth Gauge
– For use with 2.7 mm locking screws
– Threads into locking plates for correct
alignment of locking screws with plate holes
– Centers drill bits to ensure perpendicular
drilling
– Permits proper mating of locking screws
to threaded portion of the Combi hole
Technical Tip: To prevent cross-threading, turn threaded drill
guide counterclockwise until a slight click is noticed, and then
turn the drill guide clockwise. If properly aligned, threads
should engage within a quarter–turn.
The 2.0 mm threaded drill guide with depth gauge, used with
2.7 mm locking plates, can be used to establish approximate
screw length. To use, screw the 2.0 mm threaded drill guide
into one of the threaded holes and pre-drill with the 2.0 mm
Drill Bit (323.062).
Determine the length of the screw using the scale on the
drill guide. If a single marking is visible on the drill bit, the
scale from 0 mm – 30 mm applies; if a double marking is
visible, the scale from 34 mm – 60 mm.
312.648
2.8 mm Threaded Drill Guide
– For use with 3.5 mm locking screws
– Threads into locking plates for correct
alignment of locking screws with plate holes
– Centers drill bits to ensue perpendicular
drilling
– Permits proper mating of locking screws to
threaded portion of the Combi hole
Note: The threaded drill guide can also be used
intraoperatively as a reference for visualizing the angle
at which the locking screws engage in the bone.
10
Synthes Veterinary Small Fragment System
324.024
Push-Pull Reduction Device
– For use with 3.5 mm LCP plates
– Temporarily compresses plate to bone
– Can assist bone fragment reduction to plate
– Self-drilling, self-tapping 2.5 mm thread
– Synthes quick coupling connection
Insert into near cortex only. After power insertion, turn the
collet clockwise until it compresses the plate securely to the
bone. Take care when inserting this device in a hole that will
be needed for plate fixation. After the device is removed, a
conventional screw can be placed in the same hole.
511.773
Torque Limiting Attachment, 1.5 Nm,
quick coupling
511.776
Torque Limiting Attachment, 0.8 Nm,
quick coupling
A torque limiting attachment (TLA) is used to ensure the
appropriate amount of torque is applied to minimize the
risk of a locking screw backing out of the plate, and cold
welding the screw to the plate.
– Use the 1.5 Nm TLA for 3.5 mm locking screws
– Use the 0.8 Nm TLA for 2.7 mm locking screws
324.023
Threaded Plate Holder
Facilitates positioning the plate on the bone
Synthes
11
Small Fragment Standard Instrument Set (103.501)
Graphic Case
690.591
Small Fragment Instrument Set Graphic Case
Instruments
310.21
310.25
310.26
310.35
310.89
311.26
311.32
311.34
311.43
311.44
312.20
312.30
314.02
314.03
319.01
319.97
323.26
323.36
329.04
329.05
VW1203.15
VW2003.15
2.0 mm Drill Bit, quick coupling, 125 mm, 2 ea.
2.5 mm Drill Bit, quick coupling, 110 mm, 2 ea.
2.7 mm Drill Bit, quick coupling, 100 mm, 2 ea.
3.5 mm Drill Bit, quick coupling, 110 mm, 2 ea.
Countersink, for 3.5 mm Cortex and 4.0 mm
Cancellous Bone Screws
Tap for 2.7 mm Cortex Screws
Tap for 3.5 mm Cortex Screws
Tap for 4.0 mm Cancellous Bone Screws
Handle, with quick coupling
T-Handle, with quick coupling
2.0 mm Parallel Drill Guide and Drill Sleeve
3.5 mm/2.5 mm Insert Drill Sleeve
Small Hexagonal Screwdriver with Holding
Sleeve
Small Hexagonal Screwdriver Shaft
Depth Gauge, for 2.7 mm and 3.5 mm
Cortex, and 4.0 mm Cancellous Bone Screws
Screw Forceps
2.7 mm Universal Drill Guide
3.5 mm Universal Drill Guide
Bending Iron, for 2.7 mm and 3.5 mm plates,
used with 329.05
Bending Iron, for 2.7 mm and 3.5 mm plates,
used with 329.04
1.25 mm Kirschner Wire, 150 mm, trocar
point (10/pkg.)
2.0 mm Kirschner Wire, 150 mm, trocar point
(10/pkg.)
shown with both 103.501 and 103.502 set combined
Also Available
322.21
2.7 mm DCP Drill Guide, neutral and load
322.32
3.5 mm DCP Drill Guide, neutral and load
323.35
3.5 mm LC-DCP Drill Guide, neutral and load
Note: Small Fragment Instrument Set (103.503) consists of
Standard Instrument Set (103.501), with graphic case, and
Locking Instrument Set (103.502).
12
Synthes Veterinary Small Fragment System
Sterilization Parameters for LCP Plate Sets (103.501, 103.502,
103.513, 103.514, 103.516, 103.517 and 103.518)
These Synthes sets with all additionally available items, as marked in the case,
can be sterilized by the following parameters. For more information, please
refer to graphic case package insert.
Method
Cycle
Temperature
Exposure Time
Steam
Prevacuum
(Wrapped)
132°–135°C
(270°–275°F)
8 Minutes
Steam
Gravity Displacement
(Wrapped)
132°–135°C
(270°–275°F)
22 Minutes
Small Fragment Locking Instrument Set (103.502)
Instruments
310.288
312.648
314.115
314.116
314.467
314.468
323.023
323.061
323.062
324.023
324.024
VW1605.15
2.8 mm Drill Bit, quick coupling, 165 mm,
2 ea.
2.8 mm Threaded Drill Guide, 2 ea.
StarDrive Screwdriver, T15
StarDrive Screwdriver Shaft, T15, quick
coupling, 2 ea.
StarDrive Screwdriver Shaft, T8, quick
coupling, 2 ea.
Holding Sleeve, for 314.467
1.6 mm Wire Sleeve
2.0 mm Threaded Drill Guide with Depth
Gauge, 2 ea.
2.0 mm Drill Bit, with depth mark, quick
coupling, 140 mm, 2 ea.
Threaded Plate Holder
Push-Pull Reduction Device
1.6 mm Kirschner Wire with Thread,
150 mm (10/pkg.)
Also Available
Drill Bits, Jacobs chuck
310.20
2.0 mm, 85 mm
310.24
2.5 mm, 95 mm
310.27
2.7 mm, 85 mm
310.36
3.5 mm, 95 mm
323.025
Direct Measuring Device
511.773
511.776
Torque Limiting Attachments, quick coupling
1.5 Nm
0.8 Nm
310.288
312.648
314.115
314.116
314.467
314.468
323.023
323.061
323.062
324.023
324.024
VW1605.15
Synthes
13
Small Fragment Standard Screw Set (103.518)
Screw Rack
690.593
Small Fragment Standard Screw Rack
Standard Implants
2.7 mm Cortex Screws, self-tapping, 6 ea.
VS205.008
VS205.010
VS205.012
VS205.014
Length (mm)
8
10
12
14
VS205.016
VS205.018
VS205.020
Length (mm)
16
18
20
Lid not shown
3.5 mm Cortex Screws, self-tapping, 6 ea.
Length (mm)
VS302.022
VS302.012
12
VS302.024
VS302.014
14
VS302.026
VS302.016
16
VS302.028
VS302.018
18
VS302.030
VS302.020
20
Length (mm)
22
24
26
28
30
4.0 mm Cancellous Bone Screws, fully-threaded, 1 ea.
(rack will hold 4)
VS403.016
VS403.018
VS403.020
VS403.022
Length (mm)
16
18
20
22
VS403.024
VS403.026
VS403.028
VS403.030
Length (mm)
24
26
28
30
Note: Small Fragment Screw Set (103.515) consists of
Standard Screw Set (103.518) and Locking Screw Set
(103.517) stored in the optional Small Fragment Screw
Set Graphic Case (690.515).
14
Synthes Veterinary Small Fragment System
Also Available
2.7 mm Cortex Screws (rack will hold 6)
VS204.006*
VS204.008*
VS204.010*
VS204.012*
VS204.014*
VS204.016*
VS204.018*
VS204.020*
VS204.022*
VS204.024*
VS204.026*
Length (mm)
6
8
10
12
14
16
18
20
22
24
26
VS204.028*
VS204.030*
VS204.032
VS204.034
VS204.036
VS204.038
VS204.040
VS204.045
VS204.050
VS204.055
3.5 mm Cortex Screws, self-tapping (rack will hold 6)
Length (mm)
28
30
32
34
36
38
40
45
50
55
2.7 mm Cortex Screws, self-tapping (rack will hold 6)
VS205.006*
VS205.022*
VS205.024*
VS205.026*
VS205.028*
VS205.030*
VS205.032
VS205.034
VS205.036
Length (mm)
6
22
24
26
28
30
32
34
36
VS205.038
VS205.040
VS205.042
VS205.044
VS205.045
VS205.046
VS205.048
VS205.050
VS205.055
3.5 mm Cortex Screws, (rack will hold 6)
Length (mm)
VS301.032*
VS301.010* 10
VS301.034*
VS301.012* 12
VS301.036*
VS301.014* 14
VS301.038*
VS301.016* 16
VS301.040*
VS301.018* 18
VS301.045*
VS301.020* 20
VS301.050*
VS301.022* 22
VS301.055*
VS301.024* 24
VS301.060*
VS301.026* 26
VS301.065
VS301.028* 28
VS301.070
VS301.030* 30
Length (mm)
38
40
42
44
45
46
48
50
55
Length (mm)
32
34
36
38
40
45
50
55
60
65
70
VS302.010*
VS302.032*
VS302.034*
VS302.036*
VS302.038*
VS302.040*
Length (mm)
10
32
34
36
38
40
VS302.045*
VS302.050*
VS302.055*
VS302.060*
VS302.065
VS302.070
Length (mm)
45
50
55
60
65
70
4.0 mm Cancellous Screws, fully threaded, (rack will hold four
10 mm–40 mm screws, two 45 mm and 50 mm screws)
VS403.010*
VS403.012*
VS403.014*
VS403.032*
VS403.035*
VS403.036*
VS403.040*
Length (mm)
10
12
14
32
35
36
40
VS403.045*
VS403.050*
VS403.055
VS403.060
VS403.065
VS403.070
Length (mm)
45
50
55
60
65
70
4.0 mm Cancellous Bone Screws, partially threaded,
(rack will hold four 10 mm–40 mm screws, two 45 mm
and 50 mm screws)
VS404.010*
VS404.012*
VS404.014*
VS404.016*
VS404.018*
VS404.020*
VS404.022*
VS404.024*
VS404.026*
VS404.028*
Length (mm)
10
12
14
16
18
20
22
24
26
28
VS404.030*
VS404.035*
VS404.040*
VS404.045*
VS404.050*
VS404.055
VS404.060
VS404.065
VS404.070
Length (mm)
30
35
40
45
50
55
60
65
70
*Fits in screw rack
Synthes
15
Small Fragment Locking Screw Set (103.517)
Screw Rack
690.592
Small Fragment Locking Screw Rack
Implants
2.7 mm Locking Screws, self-tapping, 2 ea. (rack will hold 6)
VS206.018
VS206.020
VS206.022
VS206.024
VS206.026
VS206.028
Length (mm)
18
20
22
24
26
28
Lid not shown
3.5 mm Locking Screws, self-tapping, (rack will hold 6)
VS303.020
VS303.022
VS303.024
VS303.026
VS303.028
VS303.030
Length
(mm)
20
22
24
26
28
30
Qty.
1
2
2
2
2
2
VS303.032
VS303.034
VS303.036
VS303.038
VS303.040
VS303.045
VS303.050
Length
(mm)
32
34
36
38
40
45
50
Qty.
2
2
2
2
2
2
1
Also Available
2.7 mm Locking Screws, self-tapping (rack will hold 6)
VS206.010*
VS206.012*
VS206.014*
VS206.016*
Length (mm)
10
12
14
16
VS206.030*
VS206.032*
VS206.034*
Length (mm)
30
32
34
3.5 mm Locking Screws, self-tapping (rack will hold 6)
Length (mm)
Length (mm)
VS303.018* 18
VS303.010* 10
VS303.055* 55
VS303.012* 12
VS303.060* 60
VS303.014* 14
VS303.065
65
VS303.016* 16
VS303.070
70
Note: Small Fragment Screw Set (103.515) consists of
Standard Screw Set (103.518) and Locking Screw Set
(103.517) stored in the optional Small Fragment Screw
Set Graphic Case (690.515).
*Fits in screw rack
16
Synthes Veterinary Small Fragment System
Small Fragment DCP Plate Set (103.513)
Graphic Case
690.511
Small Fragment Plate Set Graphic Case
Implants
2.7 mm DCP Plates
Holes
VP2030.05
5
VP2030.07
7
VP2030.09
9
Length (mm)
44
60
76
3.5 mm DCP Plates
Holes
VP2040.05
5
VP2040.07
7
VP2040.09
9
Length (mm)
61
85
109
3.5 mm Broad DCP Plates
Holes
VP2050.07
7
VP2050.09
9
VP2050.11
11
Length (mm)
86
110
134
Also Available
2.7 mm DCP Plates
Holes
VP2030.02* 2
VP2030.04* 4
VP2030.06* 6
VP2030.08* 8
VP2030.10* 10
VP2030.12* 12
*Fits in case
Length (mm)
20
36
52
68
84
100
Lid not shown
Also Available continued
3.5 mm DCP Plates
Holes
VP2040.02* 2
VP2040.04* 4
VP2040.06* 6
VP2040.08* 8
VP2040.10* 10
VP2040.12* 12
VP2040.14
14
VP2040.16
16
VP2040.18
18
VP2040.20
20
VP2040.22
22
Length (mm)
25
49
73
97
121
145
169
194
217
242
265
3.5 mm Broad DCP Plates
Holes
VP2050.08* 8
VP2050.10* 10
VP2050.12* 12
VP2050.13* 13
VP2050.14* 14
VP2050.16
16
VP2050.18
18
VP2050.20
20
VP2050.22
22
Length (mm)
98
122
146
158
170
194
218
242
266
Synthes
17
Small Fragment LC-DCP Plate Set (103.514)
Graphic Case
690.511
Small Fragment Plate Set Graphic Case
Implants
2.7 mm LC-DCP Plates
Holes
VP3031.05
5
VP3031.07
7
VP3031.09
9
Length (mm)
46
64
82
3.5 mm LC-DCP Plates
Holes
VP3040.05
5
VP3040.07
7
VP3040.09
9
Length (mm)
64
90
116
3.5 mm Broad LC-DCP Plates
Holes
Length (mm)
VP3050.07
7
90
VP3050.09
9
116
VP3050.11
11
142
Also Available
2.7 mm LC-DCP Plates
Holes
VP3031.04* 4
VP3031.06* 6
VP3031.08* 8
VP3031.10* 10
VP3031.11* 11
VP3031.12* 12
VP3031.14
14
VP3031.16
16
Length (mm)
37
55
73
91
100
109
127
145
3.5 mm LC-DCP Plates
Holes
VP3040.02* 2
VP3040.03* 3
VP3040.04* 4
VP3040.06* 6
VP3040.08* 8
VP3040.10* 10
VP3040.11* 11
Length (mm)
25
38
51
77
103
129
142
*Fits in case
18
Synthes Veterinary Small Fragment System
Lid not shown
Also Available continued
3.5 mm LC-DCP Plates
Holes
VP3040.12
12*
VP3040.14
14
VP3040.15
15
VP3040.16
16
VP3040.18
18
VP3040.20
20
Length (mm)
155
181
195
207
233
259
3.5 mm Broad LC-DCP Plates
Holes
Length (mm)
VP3050.08
8*
103
VP3050.10
10*
129
VP3050.12
12*
155
VP3050.13
13*
168
VP3050.14
14*
181
VP3050.15
15
194
VP3050.16
16
207
VP3050.17
17
220
VP3050.18
18
233
VP3050.20
20
259
VP3050.22
22
285
Small Fragment LCP Plate Set (103.516)
Graphic Case
690.511
Small Fragment Plate Set Graphic Case
Implants
2.7 mm LCP Plates
Holes
VP4031.05
5
VP4031.07
7
VP4031.09
9
Length (mm)
45
63
81
3.5 mm LCP Plates
Holes
VP4040.05
5
VP4040.07
7
VP4040.09
9
Length (mm)
72
94
124
3.5 mm Broad LCP Plates
Holes
VP4045.07
7
VP4045.09
9
VP4045.11
11
Length (mm)
94
120
146
Also Available
2.7 mm LCP Plates
Holes
VP4031.04* 4
VP4031.06* 6
VP4031.08* 8
VP4031.09* 9
VP4031.10* 10
VP4031.12* 12
VP4031.14
14
VP4031.16
16
Length (mm)
36
54
72
81
90
108
126
144
3.5 mm LCP Plates
Holes
VP4040.02* 2
VP4040.03* 3
VP4040.04* 4
VP4040.06* 6
VP4040.08* 8
VP4040.10* 10
VP4040.11* 11
Length (mm)
33
46
59
85
111
137
150
2.7 mm LCP plates
and lid not shown
Also Available continued
3.5 mm LCP Plates continued
Holes
Length (mm)
VP4040.12* 12
163
VP4040.13
13
176
VP4040.14
14
189
VP4040.15
15
202
VP4040.16
16
215
VP4040.18
18
241
VP4040.20
20
267
VP4040.22
22
293
3.5 mm Broad LCP Plates
Holes
VP4045.08* 8
VP4045.10* 10
VP4045.12* 12
VP4045.13* 13
VP4045.14* 14
VP4045.15
15
VP4045.16
16
VP4045.17
17
VP4045.18
18
VP4045.20
20
VP4045.22
22
Length (mm)
107
133
159
172
185
198
211
224
237
263
289
*Fits in case
Synthes
19
Quick Reference Guide— Instruments
Part Number Description
310.21
310.25
310.26
310.35
310.89
311.26
311.32
311.34
311.43
311.44
312.20
312.30
314.02
314.03
319.01
319.97
323.26
323.36
329.04
329.05
VW1203.15
VW2003.15
310.288
312.648
314.115
314.116
314.467
323.023
323.061
323.062
324.023
324.024
VW1605.15
20
2.0 mm Drill Bit, quick coupling, 125 mm
2.5 mm Drill Bit, quick coupling, 110 mm
2.7 mm Drill Bit, quick coupling, 100 mm
3.5 mm Drill Bit, quick coupling, 110 mm
Countersink (for small screws)
Tap for 2.7 mm Cortex Screws
Tap for 3.5 mm Cortex Screws
Tap for 4.0 mm Cancellous Bone Screws
Handle, with quick coupling
T-Handle, with quick coupling
2.0 mm Parallel Drill Guide and Drill Sleeve
3.5 mm/2.5 mm Insert Drill Sleeve
Small Hexagonal Screwdriver with Holding Sleeve
Small Hexagonal Screwdriver Shaft
Depth Gauge (for small screws)
Screw Forceps
2.7 mm Universal Drill Guide
3.5 mm Universal Drill Guide
Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.05
Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.04
1.25 mm Kirschner Wire, 150 mm, trocar point
2.0 mm Kirschner Wire, 150 mm, trocar point
2.8 mm Drill Bit, quick coupling, 165 mm
2.8 mm Threaded Drill Guide
StarDrive Screwdriver, T15
StarDrive Screwdriver Shaft, T15, quick coupling
StarDrive Screwdriver Shaft, T8, quick coupling
1.6 mm Wire Sleeve
2.0 mm Threaded Drill Guide, with Depth Gauge
2.0 mm Drill Bit with depth mark, quick coupling, 140 mm
Threaded Plate Holder
Push-Pull Reduction Device
1.6 mm Kirschner Wire with Thread, 150 mm
Synthes Veterinary Small Fragment System
Small
Fragment
Standard
Instrument
Set
(103.501)
Small
Fragment
Locking
Instrument
Set
(103.502)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Small
Fragment
Instrument
Set
(103.503)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Quick Reference Guide— Implants
Part Number Description
VS205.008–
VS205.020
VS206.018–
VS206.028
VS302.012–
VS302.030
VS403.016–
VS403.030
VS303.020–
VS303.050
VP2030.05
VP2030.07
VP2030.09
VP2040.05
VP2040.07
VP2040.09
VP2050.07
VP2050.09
VP2050.11
VP3031.05
VP3031.07
VP3031.09
VP3040.05
VP3040.07
VP3040.09
VP3050.07
VP3050.09
VP3050.11
VP4031.05
VP4031.07
VP4031.09
VP4040.05
VP4040.07
VP4040.09
VP4045.07
VP4045.09
VP4045.11
2.7 mm Cortex Screws,
self-tapping, 8 mm–20 mm
2.7 mm Locking Screws,
self-tapping, 18 mm–28 mm
3.5 mm Cortex Screws,
self-tapping, 12 mm–30 mm
4.0 mm Cancellous Bone
Screws, full thread, 16 mm–30 mm
3.5 mm Locking Screws,
20 mm–50 mm
2.7 mm DCP Plate, 5 holes
2.7 mm DCP Plate, 7 holes
2.7 mm DCP Plate, 9 holes
3.5 mm DCP Plate, 5 holes
3.5 mm DCP Plate, 7 holes
3.5 mm DCP Plate, 9 holes
3.5 mm Broad DCP Plate, 7 holes
3.5 mm Broad DCP Plate, 9 holes
3.5 mm Broad DCP Plate, 11 holes
2.7 mm LC-DCP Plate, 5 holes
2.7 mm LC-DCP Plate, 7 holes
2.7 mm LC-DCP Plate, 9 holes
3.5 mm LC-DCP Plate, 5 holes
3.5 mm LC-DCP Plate, 7 holes
3.5 mm LC-DCP Plate, 9 holes
3.5 mm Broad LC-DCP Plate, 7 holes
3.5 mm Broad LC-DCP Plate, 9 holes
3.5 mm Broad LC-DCP Plate, 11 holes
2.7 mm LCP Plate, 5 holes
2.7 mm LCP Plate, 7 holes
2.7 mm LCP Plate, 9 holes
3.5 mm LCP Plate, 5 holes
3.5 mm LCP Plate, 7 holes
3.5 mm LCP Plate, 9 holes
3.5 mm Broad LCP Plate, 7 holes
3.5 mm Broad LCP Plate, 9 holes
3.5 mm Broad LCP Plate, 11 holes
Small
Small
Small
Small
Small
Small
Fragment Fragment Fragment Fragment Fragment Fragment
Standard Locking
Screw DCP Plate LC-DCP
LCP
Screw Set Screw Set
Set
Set
Plate Set Plate Set
(103.518) (103.517) (103.515) (103.513) (103.514) (103.516)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Synthes
21
Synthes (USA)
1302 Wrights Lane East
West Chester, PA 19380
Telephone: (610) 719-5000
To order: (800) 523-0322
Fax: (610) 251-9056
© 2007 Synthes, Inc. or its affiliates. All rights reserved.
Synthes (Canada) Ltd.
2566 Meadowpine Boulevard
Mississauga, Ontario L5N 6P9
Telephone: (905) 567-0440
To order: (800) 668-1119
Fax: (905) 567-3185
Combi, DCP, LC-DCP, LCP and Synthes are trademarks of Synthes, Inc. or its affiliates.
www.synthes.com
Printed in U.S.A. 12/07 J7604-A