Small Fragment System
Transcription
Small Fragment System
Small Fragment System. Instruments and implants for 2.7 mm and 3.5 mm plate fixation. Compatible with DCP, LC-DCP and LCP Plating Systems Cortex, locking and cancellous bone screws Instruments for standard and locked plating Veterinary Small Fragment System Table of Contents Introduction Small Fragment System 2 Product Information Plates 4 Screws 6 Universal Drill Guides 8 Featured Instruments 910 Set Lists 12 Sterilization Parameters 12 Quick Reference Guide— Instruments 20 Quick Reference Guide— Implants 21 Synthes Small Fragment System The Small Fragment Standard System The Small Fragment Standard System contains the 2.7 mm, 3.5 mm and 4.0 mm implants and related instruments required for standard compression plating. Features – Equipment for LC-DCP and DCP plating systems – Can be upgraded to LCP system – Cases are organized in general order of use – Compact case sizes fit most tabletop autoclaves – Plate case stores a full range of 2.7 mm, 3.5 mm, and 3.5 mm Broad DCP, LC-DCP or LCP plates – Includes auxiliary bins for storing additional equipment The standard system consists of: – Small Fragment Standard Instrument Set (103.501), – Small Fragment Standard Screw Set (103.518) – Small Fragment DCP Plate Set (103.513) or Small Fragment LC-DCP Plate Set (103.514) The Small Fragment Locking System The Small Fragment Locking System contains the 2.7 mm and 3.5 mm LCP implants and related instruments required for locked plating. Features – Unique equipment required for LCP plating – Locking instruments fit in Standard Instrument Case (690.591) – All cases are organized in general order of use – Compact case sizes fit most tabletop autoclaves The locking system consists of: – Small Fragment Locking Instrument Set (103.502) – Small Fragment Locking Screw Set (103.517) – Small Fragment LCP Plate Set (103.516) 2 Synthes Veterinary Small Fragment System Synthes 3 Plates DCP (Dynamic Compression Plate) DCP plate hole – Incorporates an incline in the hole that converts screw compression into plate translation and compression of the bone fracture – Accepts conventional screws that may be placed in either load or neutral positions, depending on whether interfragment compression is desired (see Universal Drill Guide for more detail) – Allows 25° of longitudinal screw angulation and 7° of transverse screw angulation LC-DCP (Limited Contact Dynamic Compression Plate) Grooved undersurface – Provides limited contact between the plate and bone, minimizing the chance for temporary porosis under the plate – Allows periosteal callus formation at the fracture site Bone loss observed beneath a full-contact plate LC-DCP plate hole – The dynamic compression unit (DCU) hole is symmetrical and provides bidirectional compression – Allows 40° of longitudinal screw angulation and 7° of transverse screw angulation – Accepts conventional screws that may be placed in either load or neutral positions, depending on whether interfragment compression is desired (see Universal Drill Guide for more detail) Uniform stiffness – Allows smooth contouring of the plate to the bone – Protects plate from localized high bending stress, because of the even distribution of stresses over a long distance along the plate LC-DCP DCP 4 Synthes Veterinary Small Fragment System Reduced bone loss beneath a limited-contact plate LCP (Locking Compression Plate) – Locking screws create a fixed-angle construct, resulting in angular stability – Tapered end for submuscular plate insertion, minimizing tissue trauma – Limited-contact plate design reduces plate-to-bone contact, protecting vascularity A B LCP plate holes – Dynamic compression unit (DCU) hole allows 40° of longitudinal screw angulation and 7° of transverse screw angulation – Combi holes allow placement of conventional screws on one side or locking screws on the opposite side of each hole A. Threaded hole section for locking screws B. Dynamic compression unit (DCU) hole section for conventional screws C. Locking screw in threaded side of plate hole D. Cortex screw in compression side of plate hole E. Stacked Combi hole at plate end accepts either cortex, cancellous or locking screws D C E Bibliography 1. Gasser, B., S.M. Perren, and E. Schneider. Parametric Numerical Design Optimization of Internal Fixation Plates. Transactions of the 7th Meeting. Aarhus, Denmark: European Society of Biomechanics, 1990. 2. Klaue. K. and S.M. Perren. Unconventional Shapes of the Plate Cross-Section in Internal Fixation: The Trapezoid Plate. Long Term Study of Bone Reaction in Sheep Tibiae. Davos, Switzerland: Laboratory for Experimental Surgery, AO/ASIF, 1990. Synthes 5 Screws Cortex Screws – For bicortical fixation in diaphyseal bone – Self-tapping screws are standard in all sets – Non-self-tapping screws are also available Cancellous Bone Screws – For fixation in poor quality or metaphyseal bone – Deeper threads and coarser pitch maximizes the surface area of the threads in contact with the bone, thereby increasing the screw’s holding power in softer bone Locking Screws – Use with the Locking Compression Plate (LCP) – Conical, double-lead machine thread on the head locks into threaded Combi hole or stacked Combi hole in the plate – Create a fixed-angle construct – Large core diameter provides improved bending and shear strength – StarDrive recess provides improved torque transmission to the screw, while retaining the screw without the use of a holding sleeve Screw Reference Chart Thread Diameter Screw Type Drill Bit for Threaded Hole Tap Drive Type 6 2.7 mm Cortex 2.0 mm 2.7 mm Locking 2.0 mm 3.5 mm Cortex 2.5 mm 3.5 mm Locking 2.8 mm 4.0 mm Cancellous 2.5 mm 2.7 mm 2.5 mm Hexagonal self-tapping T8 StarDrive 3.5 mm 2.5 mm Hexagonal self-tapping T15 StarDrive 4.0 mm 2.5 mm Hexagonal Synthes Veterinary Small Fragment System Screw Fixation Bicortical cortex screw fixation is the traditional method of compressing a plate to the bone. Friction between the plate and bone maintains stability. Therefore, bicortical screws require (2) cortices of fixation to achieve stability (Fig. A). A Locking screws provide stability and load transfer due to the threaded connection between the plate and screw. There is no compression of the plate to the bone. B Note: If a combination of a cortex screw and locking screws is used, a cortex screw should be inserted first to pull plate to the bone. If a locking screw is used first, care should be taken to ensure that the plate is held securely to the bone to avoid spinning of the plate about the bone. Caution: Synthes implants and instruments are manufactured with proprietary processes that produce superior products to those created by conventional manufacturing processes. Though other companies may be able to estimate the Synthes general product design, Synthes product dimensions are proprietary. The precision design of Synthes products is very important for long-term product function and optimal fit between implants. Only the finest quality materials are used to manufacture Synthes implants. The metals Synthes uses have been scientifically proven to be of the best biocompatibility and quality available today. With these features and qualities, the mixing of Synthes implants with the implants from other companies is not recommended. The overall performance may be compromised due to differences in design, chemical composition, mechanical properties, and quality. Given these qualities are trade-secret, no competitor of Synthes can make a genuine claim “the same as Synthes.” Combining implants from other companies with Synthes implants could reduce product performance. Consequently, it is strongly recommended to not mix parts from different manufacturers. Synthes 7 Universal Drill Guides The universal drill guides are the only drill guides which function in all Synthes plate holes. When a cortex or cancellous bone screw is used, a universal drill guide should be used to guide the drill bit. If the screw is intended to achieve interfragment compression, the universal drill guide should be placed in the load position, as shown. If the screw is intended to hold the plate, the universal drill guide should be placed in the neutral position. Compression (load) position Compression is achieved by placing the universal drill guide in the eccentric position, and maintaining the drill guide body above the plate as shown. Compression (load) 8 Synthes Veterinary Small Fragment System Neutral position Neutral position is achieved by placing the universal drill guide in the eccentric position, then compressing the drill guide body into the hole, which will shift the drill guide into the neutral position as shown. Note: For illustrative purposes, a Combi hole has been depicted. The same methodology applies to LC-DCP and DCP holes. Neutral Synthes 9 Featured Instruments 323.061 2.0 mm Threaded Drill Guide with Depth Gauge – For use with 2.7 mm locking screws – Threads into locking plates for correct alignment of locking screws with plate holes – Centers drill bits to ensure perpendicular drilling – Permits proper mating of locking screws to threaded portion of the Combi hole Technical Tip: To prevent cross-threading, turn threaded drill guide counterclockwise until a slight click is noticed, and then turn the drill guide clockwise. If properly aligned, threads should engage within a quarter–turn. The 2.0 mm threaded drill guide with depth gauge, used with 2.7 mm locking plates, can be used to establish approximate screw length. To use, screw the 2.0 mm threaded drill guide into one of the threaded holes and pre-drill with the 2.0 mm Drill Bit (323.062). Determine the length of the screw using the scale on the drill guide. If a single marking is visible on the drill bit, the scale from 0 mm – 30 mm applies; if a double marking is visible, the scale from 34 mm – 60 mm. 312.648 2.8 mm Threaded Drill Guide – For use with 3.5 mm locking screws – Threads into locking plates for correct alignment of locking screws with plate holes – Centers drill bits to ensue perpendicular drilling – Permits proper mating of locking screws to threaded portion of the Combi hole Note: The threaded drill guide can also be used intraoperatively as a reference for visualizing the angle at which the locking screws engage in the bone. 10 Synthes Veterinary Small Fragment System 324.024 Push-Pull Reduction Device – For use with 3.5 mm LCP plates – Temporarily compresses plate to bone – Can assist bone fragment reduction to plate – Self-drilling, self-tapping 2.5 mm thread – Synthes quick coupling connection Insert into near cortex only. After power insertion, turn the collet clockwise until it compresses the plate securely to the bone. Take care when inserting this device in a hole that will be needed for plate fixation. After the device is removed, a conventional screw can be placed in the same hole. 511.773 Torque Limiting Attachment, 1.5 Nm, quick coupling 511.776 Torque Limiting Attachment, 0.8 Nm, quick coupling A torque limiting attachment (TLA) is used to ensure the appropriate amount of torque is applied to minimize the risk of a locking screw backing out of the plate, and cold welding the screw to the plate. – Use the 1.5 Nm TLA for 3.5 mm locking screws – Use the 0.8 Nm TLA for 2.7 mm locking screws 324.023 Threaded Plate Holder Facilitates positioning the plate on the bone Synthes 11 Small Fragment Standard Instrument Set (103.501) Graphic Case 690.591 Small Fragment Instrument Set Graphic Case Instruments 310.21 310.25 310.26 310.35 310.89 311.26 311.32 311.34 311.43 311.44 312.20 312.30 314.02 314.03 319.01 319.97 323.26 323.36 329.04 329.05 VW1203.15 VW2003.15 2.0 mm Drill Bit, quick coupling, 125 mm, 2 ea. 2.5 mm Drill Bit, quick coupling, 110 mm, 2 ea. 2.7 mm Drill Bit, quick coupling, 100 mm, 2 ea. 3.5 mm Drill Bit, quick coupling, 110 mm, 2 ea. Countersink, for 3.5 mm Cortex and 4.0 mm Cancellous Bone Screws Tap for 2.7 mm Cortex Screws Tap for 3.5 mm Cortex Screws Tap for 4.0 mm Cancellous Bone Screws Handle, with quick coupling T-Handle, with quick coupling 2.0 mm Parallel Drill Guide and Drill Sleeve 3.5 mm/2.5 mm Insert Drill Sleeve Small Hexagonal Screwdriver with Holding Sleeve Small Hexagonal Screwdriver Shaft Depth Gauge, for 2.7 mm and 3.5 mm Cortex, and 4.0 mm Cancellous Bone Screws Screw Forceps 2.7 mm Universal Drill Guide 3.5 mm Universal Drill Guide Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.05 Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.04 1.25 mm Kirschner Wire, 150 mm, trocar point (10/pkg.) 2.0 mm Kirschner Wire, 150 mm, trocar point (10/pkg.) shown with both 103.501 and 103.502 set combined Also Available 322.21 2.7 mm DCP Drill Guide, neutral and load 322.32 3.5 mm DCP Drill Guide, neutral and load 323.35 3.5 mm LC-DCP Drill Guide, neutral and load Note: Small Fragment Instrument Set (103.503) consists of Standard Instrument Set (103.501), with graphic case, and Locking Instrument Set (103.502). 12 Synthes Veterinary Small Fragment System Sterilization Parameters for LCP Plate Sets (103.501, 103.502, 103.513, 103.514, 103.516, 103.517 and 103.518) These Synthes sets with all additionally available items, as marked in the case, can be sterilized by the following parameters. For more information, please refer to graphic case package insert. Method Cycle Temperature Exposure Time Steam Prevacuum (Wrapped) 132°–135°C (270°–275°F) 8 Minutes Steam Gravity Displacement (Wrapped) 132°–135°C (270°–275°F) 22 Minutes Small Fragment Locking Instrument Set (103.502) Instruments 310.288 312.648 314.115 314.116 314.467 314.468 323.023 323.061 323.062 324.023 324.024 VW1605.15 2.8 mm Drill Bit, quick coupling, 165 mm, 2 ea. 2.8 mm Threaded Drill Guide, 2 ea. StarDrive Screwdriver, T15 StarDrive Screwdriver Shaft, T15, quick coupling, 2 ea. StarDrive Screwdriver Shaft, T8, quick coupling, 2 ea. Holding Sleeve, for 314.467 1.6 mm Wire Sleeve 2.0 mm Threaded Drill Guide with Depth Gauge, 2 ea. 2.0 mm Drill Bit, with depth mark, quick coupling, 140 mm, 2 ea. Threaded Plate Holder Push-Pull Reduction Device 1.6 mm Kirschner Wire with Thread, 150 mm (10/pkg.) Also Available Drill Bits, Jacobs chuck 310.20 2.0 mm, 85 mm 310.24 2.5 mm, 95 mm 310.27 2.7 mm, 85 mm 310.36 3.5 mm, 95 mm 323.025 Direct Measuring Device 511.773 511.776 Torque Limiting Attachments, quick coupling 1.5 Nm 0.8 Nm 310.288 312.648 314.115 314.116 314.467 314.468 323.023 323.061 323.062 324.023 324.024 VW1605.15 Synthes 13 Small Fragment Standard Screw Set (103.518) Screw Rack 690.593 Small Fragment Standard Screw Rack Standard Implants 2.7 mm Cortex Screws, self-tapping, 6 ea. VS205.008 VS205.010 VS205.012 VS205.014 Length (mm) 8 10 12 14 VS205.016 VS205.018 VS205.020 Length (mm) 16 18 20 Lid not shown 3.5 mm Cortex Screws, self-tapping, 6 ea. Length (mm) VS302.022 VS302.012 12 VS302.024 VS302.014 14 VS302.026 VS302.016 16 VS302.028 VS302.018 18 VS302.030 VS302.020 20 Length (mm) 22 24 26 28 30 4.0 mm Cancellous Bone Screws, fully-threaded, 1 ea. (rack will hold 4) VS403.016 VS403.018 VS403.020 VS403.022 Length (mm) 16 18 20 22 VS403.024 VS403.026 VS403.028 VS403.030 Length (mm) 24 26 28 30 Note: Small Fragment Screw Set (103.515) consists of Standard Screw Set (103.518) and Locking Screw Set (103.517) stored in the optional Small Fragment Screw Set Graphic Case (690.515). 14 Synthes Veterinary Small Fragment System Also Available 2.7 mm Cortex Screws (rack will hold 6) VS204.006* VS204.008* VS204.010* VS204.012* VS204.014* VS204.016* VS204.018* VS204.020* VS204.022* VS204.024* VS204.026* Length (mm) 6 8 10 12 14 16 18 20 22 24 26 VS204.028* VS204.030* VS204.032 VS204.034 VS204.036 VS204.038 VS204.040 VS204.045 VS204.050 VS204.055 3.5 mm Cortex Screws, self-tapping (rack will hold 6) Length (mm) 28 30 32 34 36 38 40 45 50 55 2.7 mm Cortex Screws, self-tapping (rack will hold 6) VS205.006* VS205.022* VS205.024* VS205.026* VS205.028* VS205.030* VS205.032 VS205.034 VS205.036 Length (mm) 6 22 24 26 28 30 32 34 36 VS205.038 VS205.040 VS205.042 VS205.044 VS205.045 VS205.046 VS205.048 VS205.050 VS205.055 3.5 mm Cortex Screws, (rack will hold 6) Length (mm) VS301.032* VS301.010* 10 VS301.034* VS301.012* 12 VS301.036* VS301.014* 14 VS301.038* VS301.016* 16 VS301.040* VS301.018* 18 VS301.045* VS301.020* 20 VS301.050* VS301.022* 22 VS301.055* VS301.024* 24 VS301.060* VS301.026* 26 VS301.065 VS301.028* 28 VS301.070 VS301.030* 30 Length (mm) 38 40 42 44 45 46 48 50 55 Length (mm) 32 34 36 38 40 45 50 55 60 65 70 VS302.010* VS302.032* VS302.034* VS302.036* VS302.038* VS302.040* Length (mm) 10 32 34 36 38 40 VS302.045* VS302.050* VS302.055* VS302.060* VS302.065 VS302.070 Length (mm) 45 50 55 60 65 70 4.0 mm Cancellous Screws, fully threaded, (rack will hold four 10 mm–40 mm screws, two 45 mm and 50 mm screws) VS403.010* VS403.012* VS403.014* VS403.032* VS403.035* VS403.036* VS403.040* Length (mm) 10 12 14 32 35 36 40 VS403.045* VS403.050* VS403.055 VS403.060 VS403.065 VS403.070 Length (mm) 45 50 55 60 65 70 4.0 mm Cancellous Bone Screws, partially threaded, (rack will hold four 10 mm–40 mm screws, two 45 mm and 50 mm screws) VS404.010* VS404.012* VS404.014* VS404.016* VS404.018* VS404.020* VS404.022* VS404.024* VS404.026* VS404.028* Length (mm) 10 12 14 16 18 20 22 24 26 28 VS404.030* VS404.035* VS404.040* VS404.045* VS404.050* VS404.055 VS404.060 VS404.065 VS404.070 Length (mm) 30 35 40 45 50 55 60 65 70 *Fits in screw rack Synthes 15 Small Fragment Locking Screw Set (103.517) Screw Rack 690.592 Small Fragment Locking Screw Rack Implants 2.7 mm Locking Screws, self-tapping, 2 ea. (rack will hold 6) VS206.018 VS206.020 VS206.022 VS206.024 VS206.026 VS206.028 Length (mm) 18 20 22 24 26 28 Lid not shown 3.5 mm Locking Screws, self-tapping, (rack will hold 6) VS303.020 VS303.022 VS303.024 VS303.026 VS303.028 VS303.030 Length (mm) 20 22 24 26 28 30 Qty. 1 2 2 2 2 2 VS303.032 VS303.034 VS303.036 VS303.038 VS303.040 VS303.045 VS303.050 Length (mm) 32 34 36 38 40 45 50 Qty. 2 2 2 2 2 2 1 Also Available 2.7 mm Locking Screws, self-tapping (rack will hold 6) VS206.010* VS206.012* VS206.014* VS206.016* Length (mm) 10 12 14 16 VS206.030* VS206.032* VS206.034* Length (mm) 30 32 34 3.5 mm Locking Screws, self-tapping (rack will hold 6) Length (mm) Length (mm) VS303.018* 18 VS303.010* 10 VS303.055* 55 VS303.012* 12 VS303.060* 60 VS303.014* 14 VS303.065 65 VS303.016* 16 VS303.070 70 Note: Small Fragment Screw Set (103.515) consists of Standard Screw Set (103.518) and Locking Screw Set (103.517) stored in the optional Small Fragment Screw Set Graphic Case (690.515). *Fits in screw rack 16 Synthes Veterinary Small Fragment System Small Fragment DCP Plate Set (103.513) Graphic Case 690.511 Small Fragment Plate Set Graphic Case Implants 2.7 mm DCP Plates Holes VP2030.05 5 VP2030.07 7 VP2030.09 9 Length (mm) 44 60 76 3.5 mm DCP Plates Holes VP2040.05 5 VP2040.07 7 VP2040.09 9 Length (mm) 61 85 109 3.5 mm Broad DCP Plates Holes VP2050.07 7 VP2050.09 9 VP2050.11 11 Length (mm) 86 110 134 Also Available 2.7 mm DCP Plates Holes VP2030.02* 2 VP2030.04* 4 VP2030.06* 6 VP2030.08* 8 VP2030.10* 10 VP2030.12* 12 *Fits in case Length (mm) 20 36 52 68 84 100 Lid not shown Also Available continued 3.5 mm DCP Plates Holes VP2040.02* 2 VP2040.04* 4 VP2040.06* 6 VP2040.08* 8 VP2040.10* 10 VP2040.12* 12 VP2040.14 14 VP2040.16 16 VP2040.18 18 VP2040.20 20 VP2040.22 22 Length (mm) 25 49 73 97 121 145 169 194 217 242 265 3.5 mm Broad DCP Plates Holes VP2050.08* 8 VP2050.10* 10 VP2050.12* 12 VP2050.13* 13 VP2050.14* 14 VP2050.16 16 VP2050.18 18 VP2050.20 20 VP2050.22 22 Length (mm) 98 122 146 158 170 194 218 242 266 Synthes 17 Small Fragment LC-DCP Plate Set (103.514) Graphic Case 690.511 Small Fragment Plate Set Graphic Case Implants 2.7 mm LC-DCP Plates Holes VP3031.05 5 VP3031.07 7 VP3031.09 9 Length (mm) 46 64 82 3.5 mm LC-DCP Plates Holes VP3040.05 5 VP3040.07 7 VP3040.09 9 Length (mm) 64 90 116 3.5 mm Broad LC-DCP Plates Holes Length (mm) VP3050.07 7 90 VP3050.09 9 116 VP3050.11 11 142 Also Available 2.7 mm LC-DCP Plates Holes VP3031.04* 4 VP3031.06* 6 VP3031.08* 8 VP3031.10* 10 VP3031.11* 11 VP3031.12* 12 VP3031.14 14 VP3031.16 16 Length (mm) 37 55 73 91 100 109 127 145 3.5 mm LC-DCP Plates Holes VP3040.02* 2 VP3040.03* 3 VP3040.04* 4 VP3040.06* 6 VP3040.08* 8 VP3040.10* 10 VP3040.11* 11 Length (mm) 25 38 51 77 103 129 142 *Fits in case 18 Synthes Veterinary Small Fragment System Lid not shown Also Available continued 3.5 mm LC-DCP Plates Holes VP3040.12 12* VP3040.14 14 VP3040.15 15 VP3040.16 16 VP3040.18 18 VP3040.20 20 Length (mm) 155 181 195 207 233 259 3.5 mm Broad LC-DCP Plates Holes Length (mm) VP3050.08 8* 103 VP3050.10 10* 129 VP3050.12 12* 155 VP3050.13 13* 168 VP3050.14 14* 181 VP3050.15 15 194 VP3050.16 16 207 VP3050.17 17 220 VP3050.18 18 233 VP3050.20 20 259 VP3050.22 22 285 Small Fragment LCP Plate Set (103.516) Graphic Case 690.511 Small Fragment Plate Set Graphic Case Implants 2.7 mm LCP Plates Holes VP4031.05 5 VP4031.07 7 VP4031.09 9 Length (mm) 45 63 81 3.5 mm LCP Plates Holes VP4040.05 5 VP4040.07 7 VP4040.09 9 Length (mm) 72 94 124 3.5 mm Broad LCP Plates Holes VP4045.07 7 VP4045.09 9 VP4045.11 11 Length (mm) 94 120 146 Also Available 2.7 mm LCP Plates Holes VP4031.04* 4 VP4031.06* 6 VP4031.08* 8 VP4031.09* 9 VP4031.10* 10 VP4031.12* 12 VP4031.14 14 VP4031.16 16 Length (mm) 36 54 72 81 90 108 126 144 3.5 mm LCP Plates Holes VP4040.02* 2 VP4040.03* 3 VP4040.04* 4 VP4040.06* 6 VP4040.08* 8 VP4040.10* 10 VP4040.11* 11 Length (mm) 33 46 59 85 111 137 150 2.7 mm LCP plates and lid not shown Also Available continued 3.5 mm LCP Plates continued Holes Length (mm) VP4040.12* 12 163 VP4040.13 13 176 VP4040.14 14 189 VP4040.15 15 202 VP4040.16 16 215 VP4040.18 18 241 VP4040.20 20 267 VP4040.22 22 293 3.5 mm Broad LCP Plates Holes VP4045.08* 8 VP4045.10* 10 VP4045.12* 12 VP4045.13* 13 VP4045.14* 14 VP4045.15 15 VP4045.16 16 VP4045.17 17 VP4045.18 18 VP4045.20 20 VP4045.22 22 Length (mm) 107 133 159 172 185 198 211 224 237 263 289 *Fits in case Synthes 19 Quick Reference Guide— Instruments Part Number Description 310.21 310.25 310.26 310.35 310.89 311.26 311.32 311.34 311.43 311.44 312.20 312.30 314.02 314.03 319.01 319.97 323.26 323.36 329.04 329.05 VW1203.15 VW2003.15 310.288 312.648 314.115 314.116 314.467 323.023 323.061 323.062 324.023 324.024 VW1605.15 20 2.0 mm Drill Bit, quick coupling, 125 mm 2.5 mm Drill Bit, quick coupling, 110 mm 2.7 mm Drill Bit, quick coupling, 100 mm 3.5 mm Drill Bit, quick coupling, 110 mm Countersink (for small screws) Tap for 2.7 mm Cortex Screws Tap for 3.5 mm Cortex Screws Tap for 4.0 mm Cancellous Bone Screws Handle, with quick coupling T-Handle, with quick coupling 2.0 mm Parallel Drill Guide and Drill Sleeve 3.5 mm/2.5 mm Insert Drill Sleeve Small Hexagonal Screwdriver with Holding Sleeve Small Hexagonal Screwdriver Shaft Depth Gauge (for small screws) Screw Forceps 2.7 mm Universal Drill Guide 3.5 mm Universal Drill Guide Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.05 Bending Iron, for 2.7 mm and 3.5 mm plates, used with 329.04 1.25 mm Kirschner Wire, 150 mm, trocar point 2.0 mm Kirschner Wire, 150 mm, trocar point 2.8 mm Drill Bit, quick coupling, 165 mm 2.8 mm Threaded Drill Guide StarDrive Screwdriver, T15 StarDrive Screwdriver Shaft, T15, quick coupling StarDrive Screwdriver Shaft, T8, quick coupling 1.6 mm Wire Sleeve 2.0 mm Threaded Drill Guide, with Depth Gauge 2.0 mm Drill Bit with depth mark, quick coupling, 140 mm Threaded Plate Holder Push-Pull Reduction Device 1.6 mm Kirschner Wire with Thread, 150 mm Synthes Veterinary Small Fragment System Small Fragment Standard Instrument Set (103.501) Small Fragment Locking Instrument Set (103.502) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Small Fragment Instrument Set (103.503) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Quick Reference Guide— Implants Part Number Description VS205.008– VS205.020 VS206.018– VS206.028 VS302.012– VS302.030 VS403.016– VS403.030 VS303.020– VS303.050 VP2030.05 VP2030.07 VP2030.09 VP2040.05 VP2040.07 VP2040.09 VP2050.07 VP2050.09 VP2050.11 VP3031.05 VP3031.07 VP3031.09 VP3040.05 VP3040.07 VP3040.09 VP3050.07 VP3050.09 VP3050.11 VP4031.05 VP4031.07 VP4031.09 VP4040.05 VP4040.07 VP4040.09 VP4045.07 VP4045.09 VP4045.11 2.7 mm Cortex Screws, self-tapping, 8 mm–20 mm 2.7 mm Locking Screws, self-tapping, 18 mm–28 mm 3.5 mm Cortex Screws, self-tapping, 12 mm–30 mm 4.0 mm Cancellous Bone Screws, full thread, 16 mm–30 mm 3.5 mm Locking Screws, 20 mm–50 mm 2.7 mm DCP Plate, 5 holes 2.7 mm DCP Plate, 7 holes 2.7 mm DCP Plate, 9 holes 3.5 mm DCP Plate, 5 holes 3.5 mm DCP Plate, 7 holes 3.5 mm DCP Plate, 9 holes 3.5 mm Broad DCP Plate, 7 holes 3.5 mm Broad DCP Plate, 9 holes 3.5 mm Broad DCP Plate, 11 holes 2.7 mm LC-DCP Plate, 5 holes 2.7 mm LC-DCP Plate, 7 holes 2.7 mm LC-DCP Plate, 9 holes 3.5 mm LC-DCP Plate, 5 holes 3.5 mm LC-DCP Plate, 7 holes 3.5 mm LC-DCP Plate, 9 holes 3.5 mm Broad LC-DCP Plate, 7 holes 3.5 mm Broad LC-DCP Plate, 9 holes 3.5 mm Broad LC-DCP Plate, 11 holes 2.7 mm LCP Plate, 5 holes 2.7 mm LCP Plate, 7 holes 2.7 mm LCP Plate, 9 holes 3.5 mm LCP Plate, 5 holes 3.5 mm LCP Plate, 7 holes 3.5 mm LCP Plate, 9 holes 3.5 mm Broad LCP Plate, 7 holes 3.5 mm Broad LCP Plate, 9 holes 3.5 mm Broad LCP Plate, 11 holes Small Small Small Small Small Small Fragment Fragment Fragment Fragment Fragment Fragment Standard Locking Screw DCP Plate LC-DCP LCP Screw Set Screw Set Set Set Plate Set Plate Set (103.518) (103.517) (103.515) (103.513) (103.514) (103.516) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Synthes 21 Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 © 2007 Synthes, Inc. or its affiliates. All rights reserved. Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 Combi, DCP, LC-DCP, LCP and Synthes are trademarks of Synthes, Inc. or its affiliates. www.synthes.com Printed in U.S.A. 12/07 J7604-A