APPLICATION INSTRUCTIONS

Transcription

APPLICATION INSTRUCTIONS
APPLICATION INSTRUCTIONS
GENERAL INFORMATION: MiraTEC Treated Exterior Composite Prefinished Trim is
16'' O.C.
)
or
ater
m
an engineered wood composite trim designed for use in both exterior and interior applications where a
Rafter
non-structural
smooth or wood grain textured blemish-free trim product is desired. MiraTEC prefinished
trim resists moisture, rot and termites. MiraTEC alberga el ESR-3043 del Servicio de Evaluación ICC.
Patented
Sub-fascia is
recommended
in regions of
high humidity
or extreme
humidity changes.
CUTTING:
Rafter
16'' O.C.
Sub-fascia is
recommended
in regions of
high humidity
or extreme
humidity changes.
Fascia
Use a fine-tooth hand saw or power saw with a combination blade.
Cut into the painted face of the
Rafter
material. Carbide-tipped blades are recommended.
Fascia
16'' O.C.
FASTENING REQUIREMENTS:
24" max
Sub-fascia is
recommended
Rafter
Fascia Application
in regions of
MiraTEC prefinished trim is a non-structural decorative trim product
and should not be used
high humidity
or extreme
where structural lumber properties
are
required.
MiraTEC
prefinished
trim is designed to be
Rafter
humidity changes.
Fascia
applied to structural
framing,
sheathing
and
other
materials.
16'' O.C.
Siding
16˝ O.C.
Sub-fascia is
Continuous
recommended
horizontal
16''
O.C. in regions of
flashing high
withhumidity
drip & 2˝or(min.)
extreme
overlapshumidity changes.
& joints
Fascia
Siding
Window or door
head casing, water
table or other
horizontal trim
Sub-fascia is
recommended
in regions of
high humidity
or extreme
humidity changes.
Continuous
horizontal
flashing with
max
drip & 2˝24"
(min.)
overlaps
& joints
Fascia
Application
24" max
Fascia Application
Sub-fascia is
recommended
in regions of
Siding
24"
max
high humidity
Fascia Application or extreme
Continuous
humidity changes.
horizontal
Rafter
16˝ O.C.
flashing with
drip & 2˝ (min.)
overlaps
16˝ O.C.
Fascia & joints
Fascia
Window or door
head casing, water
table or other
24" max
horizontal trim
Fascia Application
24" max
Fascia Application
Fascia
Application
Window
or edge.
door
*Note: Nail at least 1/2˝ from
the
Do not nail into the edges of MiraTEC prefinished trim. For 4/4 and 5/4 fascia and
head casing, water
soffit applications, MiraTEC
prefinished
trim can be fastened directly to the rafter ends, double nailed a minimum of 24˝
table or other
CORRECT
trim and vertical applications, double
16˝ nail
O.C. 16˝ on center, falling on the studs.
on center. ForSiding
all otherhorizontal
horizontal
CORRECT
Siding
16˝ O.C.
Gap 1/8''
16˝ O.C.
Framing
Continuous
Fasten MiraTEC
prefinished trim from Seal Joint
horizontal
Continuous
one flashing
end towith
the other end.
horizontal
drip & 2˝ (min.) 1/2'' min
INCORRECT
overlaps
CORRECT
flashing with
& joints
Window or door
head casing, water
table or other
INCORRECT
horizontal trim
DO NOT nail toward the
center from both ends.
INCORRECT
drip & 2˝ (min.)
16'' max
Gap 1/8''
Double nail on both sides of butt joint
overlaps
& joints
Framing
Gap 1/8''
Seal Joint
1/2'' min
16'' max
Framing
Double nail on both sides of butt joint
Seal Joint
1/2'' min
Window or door
16'' max
Double nail on both sides of butt joint
head casing, water
All joints must fall over a framing member.
MiraTEC
prefinished trim can be mitered, scarfed, or beveled as required. For runs less than 30 feet
table
or other
in length, butt joints should lightly touch.horizontal
For runs overtrim
30 feet in length, space all butt and scarf joints 1/8˝ apart and apply sealant into the full
BUTT JOINTS:
depth of the 1/8˝ joint. Double nail all joints on both sides as noted in the diagram.
CORRECT
When mitering for column wraps or corner boards, JELD-WEN, inc. recommends gluing the edges of the trim to maintain a tight joint. Use a
Framing
1/8''
quality exterior grade yellow carpenters glue or highGap
quality
polyurethane adhesive. Lightly ease the edge of the finished corner with 220 grit
Seal Joint
sand paper for best paint adhesion.
INCORRECT
Gap 1/8''
CORRECT
Framing
Seal Joint
1/2'' min
16'' max
Double nail on both sides of butt joint
Gap 1/8''
1/2'' min
16'' max
INCORRECT
Double nail on both sides of butt joint
Framing
Glue
Seal
Mitered Joint
Edges
1/2'' min
16'' max
Double nail on both sides of butt joint
FASTENERS:
Always use fasteners appropriate to the style of construction where the prefinished trim
is installed. Fasteners must be equal or better in performance (such as nail withdrawal,
bending strength and corrosion resistance) to 6d or 8d 16 gauge finish nails or headed
nails, long enough to penetrate 1 1/4˝ into structural wood studs or studs and structural sheathing material. Use nails with corrosive resistance equivalent to hot dipped
galvanized nails. For buildings utilizing steel studs, use ET&F fasteners: AST-075 for 4/4
MiraTEC and AST-100 for 5/4 MiraTEC. For installations near oceans, large bodies of
water or in high humidity climates, JELD-WEN, inc. recommends using stainless steel fasteners on MiraTEC prefinished trim. For these installations, do not use electro-galvanized
fasteners, due to poor long term rust resistance.
CONDITION
Power
or pneumatic nailing systems may be used. Visit www.miratectrim.com for infor16'' O.C.
is
mation on air pressure settings on a variety of pneumatic nailers. Tapered orSub-fascia
bugle head
fasteners are permitted when the heads are properly sealed from moisture.recommended
Visible fiber
in regions of
high humidity
or extreme
putty
specifihumidity changes.
Nail heads, or any other dents, can be filled with exterior grade spackling
cally designed for filling nail holes. Allow putty to dry, sand smooth with 100 grit sandpaper and spot prime before painting. Over time, spackling putty may need to be replaced
or touched up.
Use a nail that is appropriate to the style of construction. Do not use
staples, braids, or t-nails
CONDITION
Snug
OK
Flush
OK
Rafter
Counter sunk
1/16˝ - 1/8˝
Paint
Exterior putty
Fascia
Counter sunk
more than 1/8˝
Exterior putty &
add nail
24" max
Fascia Application
FLASHING AND MOISTURE CONTROL:
Siding
Continuous
horizontal
flashing with
drip & 2˝ (min.)
overlaps
& joints
Window or door
head casing, water
table or other
horizontal trim
The structure on which MiraTEC prefinished trim is applied should be well ventilated and dry. Do not apply MiraTEC prefinished trim over wet sheathing, or any
closer than 6˝ to finished grade or final landscaping.
As with all wood products,
16˝ O.C.
MiraTEC prefinished trim should not come in direct contact with masonry or
concrete. At foundations or exterior brick veneer, the product should be separated from the masonry by metal flashing, polyethylene film, 30 lb. felt or a 1/4˝ to
1/2˝ air space using masonry standoffs. In all applications, MiraTEC prefinished trim
should not be allowed to stand in water.
Seal the trim applications to prevent water intrusion. Do not
allow water to stand on or leak behind any MiraTEC prefinished
trim. MiraTEC prefinished trim used in a horizontal application,
including window and door headers, must be properly flashed in
accordance with the siding manufacturers’, window manufacturers’, or
door manufacturers’ application requirements and local building codes.
ADHESIVES:
Glues or adhesives can be used on MiraTEC prefinished trim such as on mitered joints for outside corners or column wraps. Use a
high quality exterior grade yellow carpenters glue or a high quality polyurethane adhesive.
SEALANT:
CORRECT
Framing
Gapabuts
1/8'' siding, windows, doors
Sealant is required at butt joints and where MiraTEC prefinished trim
or other materials. Use only exteSeal Joint to the manufacturer’s written
rior quality sealant that remains flexible over time. Do not use hard-setting caulk. Apply caulk according
instructions. JELD-WEN, inc. recommends caulks and sealants that meet ASTM C920. Do not use Bondo® or similar hard setting fillers
or putties on MiraTEC prefinished trim. They will crack over time due to the natural expansion and contraction of the trim.
INCORRECT
1/2'' min
16'' max
Double nail on both sides of butt joint
MiraTEC trim
SPECIFIC APPLICATIONS
Flashing
For applications near rooflines, such as dormer
and chimneys, the trim should be installed with a minimum of 1˝ clearance between the
1/2'' Gap Between
Trim and Flashing
roofing and the bottom edge of MiraTEC prefinished trim. At the junction of the roofing material and vertical surfaces, flashing is required
per the roofing manufacturers’ application requirements and local building codes.
When facing the skirt boards
on deck, properly flash the top
edge to prevent water from
getting behind the trim. As a
substitute for flashing, use 1/2˝
standoffs to provide a space
behind the backside of the trim
and the deck skirt board.
MiraTEC trim
1˝ gap
between
the shingles
and trim
Flashing
Flashing
MiraTEC
MiraTEC
Properly flash and space at
least 1/2˝ from any concrete
flatwork (such as porches,
patios, or driveways) or
horizontal brick ledge.
MiraTEC trim
Flashing
MiraTEC
1/2˝ Space
Flashing
MiraTEC
Decorative
Shutters
24˝ max.
spacing
MiraTEC prefinished trim can be used
to make decorative shutters. The
shutter must be fastened to the home
a minimum of 24˝ on center around
the perimeter of the shutter as shown
in the illustration. Working shutters will
not be covered under the MiraTEC
warranty due to the inability to provide
adequate fastening on the non hinge
side of the shutter.
1/4˝ Clearance
MiraTEC
When vertical trim meets flashing at
the top of trim or siding, provide a
1/4˝ clearance from the bottom of the
trim to the top of the flashing.
SURFACE PREPARATION:
The surface to be painted must be free of dust, dirt, mildew and other foreign materials before painting. Wash with water and a mild
detergent to remove dust and dirt. Allow the surface to dry before painting. If mildew is present, contact a paint supply store for
recommended methods of removing and controlling mildew.
MiraTEC
TOUCH UP AND PAINTING:
1/2˝ Space
MiraTEC prefinished trim is manufactured from wood, and all exposed surfaces must be primed and/or painted according to the following
procedures:
1. CUT EDGES AND ENDS: All exposed cut edges and ends must be primed prior to or within 30 days of installation using
a high quality exterior primer recommended by the manufacturer for use on composite wood. If these edges/ends will be
exposed to the weather and will be visible, they must be topcoated using touch up paint. Any surface damages can also
be covered up with touch up paint.
2. TOUCH UP PROCEDURE: Follow all touch-up procedures as defined by the prefinisher. This includes guidelines for
surface preparation, temperature requirements, application tools, etc.
5/16'' max depth
5/16'' max depth
5/16'' max depth
5/16'' max depth
Patented
MACHINING:
MiraTEC prefinished trim can be grooved or machined to produce a variety of decorative applications.
The machined profile should not compromise the physical integrity of the board or induce cracking or
splitting of the product. Routed or grooved MiraTEC prefinished trim should not have any flat surfaces
where water can accumulate. Maintain an angle of at least 100 degrees from the vertical to provide positive drainage and to prevent moisture from standing on the surface. Re-prime all machined areas with a
high quality exterior oil or acrylic latex primer formulated for composite wood. JELD-WEN, inc. recommends using an oil-based primer.
STORAGE:
5/16'' max depth
5/16'' max depth
Examples of machining
Cover when stored outside. Keep MiraTEC prefinished trim off the
ground and dry. Excessive moisture pickup from improper storage may
affect the performance of MiraTEC prefinished trim. Do not stack material in excess of 3 units high.
Tarp to cover
MiraTEC
For job site storage, the material should be placed on stringers and
covered, preferably on concrete, asphalt, or similar surface. For all other
instances, a tarp should be placed over the ground cover under the
stringers, with the material still under cover.
MiraTEC trim
TYPICAL TRIM USES:
Ground tarp
MiraTEC prefnished trim can be used in a variety of applications as noted below.
7
2
1
3
8
5
6
6
9
10
4
1
Soffit
2
Frieze board
3
Fascia
4
Belly band or band board
5
Window trim
6
Corner board
7
Rake board or shingle mold
8
Architectural porch detail
9
Column wrap
10 Fluted door casing
IMPORTANTE: Lea y comprenda todas las instrucciones de aplicación antes de instalar el material. Las declaraciones expresadas en este boletín técnico son recomendaciones para la
aplicación de los productos como se detalla e ilustra conforme a condiciones normales de instalación. JELD-WEN, inc. es un fabricante de materiales de construcción. No ejerce la arquitectura ni la ingeniería. Las recomendaciones otorgadas en este boletín representan el mejor criterio de JELD-WEN, inc. Basado en su experiencia hasta la fecha con aplicaciones normales.
Estas instrucciones complementan las prácticas de construcción estándar y los requisitos del código de construcción; no se deben considerar exclusivas o excluyentes de estas prácticas
y requisitos. A menos que se obtenga una aprobación escrita anteriormente por parte del Departamento de Rendimiento del Producto de JELD-WEN, inc., PO Box 311, Towanda, PA
188-48, cualquier desviación de estos procedimientos recomendados quedará a exclusivo riesgo de los instaladores.
Estas instrucciones de aplicación constituyen los requisitos mínimos para el almacenamiento, la aplicación y el acabado de los productos de molduras fabricados por JELD-WEN, inc. En
donde los requisitos o estándares del código de construcción sean más restrictivos, se deben seguir las regulaciones aplicables. Consulte a su representante local o al Departamento
de Rendimiento del Producto por las condiciones que no estén cubiertas por este boletín. Todos los planos se muestran únicamente a título informativo y no están a escala. El diseño
adecuado y el apuntalamiento de las paredes, así como el cumplimiento de estas instrucciones de aplicación, quedan bajo la responsabilidad del arquitecto, constructor, aplicador o pintor.
1.800.255.0785
miratectrim.com
R 20827
Class C Fire Rating
Flame Spread 120
Smoke Developed 90
© 2013 JELD-WEN, inc. Todos los derechos