Rhinoscope Washing
Transcription
Rhinoscope Washing
A New Medical Device Design for Rhinoscope Washing Fujian Medical University Union Hospital P.R. of China ZHANG XIAOCHUN II: Objects: • • • • • A Brief Introduction of Fujian Medical University Union Hospital • • • • Established in 1860 as a missionary hospital First batch 3A general hospital in Jiangsu province (1993) Hospital Beds: 2211 Actual Beds: 2500 Staff: 3350 • • • outpatient and emergency visits per year: 1.98 million Annual number of discharges: 92000 Annual number of surgery: 87000 III: Methods • Washing the more medical device every load • Improve the cleaning quality Be more efficiency to use the spaces Easy to operate and easy to take away Save the material cost The new design be less weight Deliver or place the rhinoscope device be more stable I: Background Column B • The rhinoscope are widely used in hospital, they made by stainless steel, expensive and reused. So the washing and cleaning are very important to the patient. • The front part of rhinoscope touch each other very closely for the normal placement. These treatment surely be more difficult to cleaning and washing. • The front part (especially the two tips) touched the patient frequently, so the part will concentrate more microbe. • Before used the new design, we found less way to be more high efficiency and convenient process to washing the rhinoscope. III: Methods Column A • Use the Column A to open the wide mouth for convenient washing and cleaning. • Use the Column B to place rhinoscope medical device more stable during the washing. • These two column use the “U shape” be more costly and durable. Handle A • Use the Handle A & B for both side to keep the device steady and move convenient. • Made by stainless steel to keep the construction strong. • Cross over each other to save the space and improve the cleaning quality. Handle B IV: Results Certificate of utility model patent Patent Number:ZL 2015 2 0275266.7 Apply Date:2015.04.30 Authorize Date:2015.09.09 V:Conclusion • After used this medical device, we found, use new design is very important to cleaning and washing the rhinoscope . Especially to tip parts, be more high efficiency and convenient process to washing and cleaning. Before Use mess and difficult to washing After Use In order and easy to washing A Brief Introduction of Fujian Medical University Union CSSD • • • • Area: 1350 square-meter Staff Member: 50 Nurse: 30 Technician : 20 • Processed Instruments/Packs Per Day 3000 • • Author Director of CSSD Zhang Xiaochun