AVCSMC_Aria Versadisc Installation Guide_01

Transcription

AVCSMC_Aria Versadisc Installation Guide_01
INSTALLATION GUIDE
Aria Versadiscâ„¢ Shower Mixer
AVCSMC
System Requirements
MINIMUM
COLD
Unequal Pressures
MINIMUM
HOT
Operating Pressures
35kPa (5.1psi) 200kPa (29.0psi)
Equal High (MAINS) & Equal Low Pressures
Operating Pressures
MINIMUM
35kPa (5.1psi)
MAXIMUM
1500kPa (217.6psi)
MAXIMUM
1500kPa (217.6psi)
Operating Hot Water Temperatures
55° C
80° C
Operating Cold Water Temperatures
5° C
N/A
Note - Do not plug outlet when testing.
This shower mixer can be line tested up to 1500kPa (217.6psi)
When line testing ensure handle is open or closed in full hot or full cold position.
Do not line test in mixed hot/cold position or rotate from full hot or full cold when under pressure.
Contents of Pack
Faceplate
Mixer Assembly
(Factory-fitted with white
unequal pressures sub-cartridge)
Green equal pressures
sub-cartridge
Handle
8g x 32 Dome Head
Square Drive
Stainless Steel Screws
Allen Key
Unequal Pressure
Install product as supplied (factory fitted with white unequal pressures sub-cartridge)
Equal Low Pressure or Equal High/Mains Pressure
ove
Rem
te
Whi
Fit
Green
040613DT
Before Installation
Pipework MUST be purged before connecting to the mixer
Mixer Orientation
This mixer is designed to be connected with the hot water supply on the left only and the cold water
supply on the right only.
Top Outlet Option
HOT Inlet only
COLD Inlet only
Bottom Outlet Option
Mixer Installation
Ø8 Cut a
0m
m hole
-Ø
85m
m
No minimum
straight distance
HO
Ts
upp
ly o
nly
CO
LD
sup
ply
onl
y
Min 35mm
Max 110mm
Tighten ALL 4 SCREWS on
the inner circle of the faceplate
Seal with silicon
if necessary
For technical assistance please ring: 0800 743 358 or (09) 528 0810
Felton Industries Limited
8 Farmhouse Lane, Glen Innes, Auckland 1072 New Zealand
www.felton.co.nz