AVCSMC_Aria Versadisc Installation Guide

Transcription

AVCSMC_Aria Versadisc Installation Guide
INSTALLATION GUIDE
Aria SmartFlowâ„¢ Thermostatic Shower Mixer
ASCSMC
System Requirements
MINIMUM
70kPa (10.15psi)
MAXIMUM
500kPa (72.51psi)
Operating Hot Water Temperatures
55° C
80° C
Operating Cold Water Temperatures
5° C
N/A
Operating Pressures
Note - Do not plug outlet when testing.
This shower mixer will function with pressures as low as 36kPa and as high as 700kPa, but for the best results,
a minimum of 70 kPa and a maximum of 500kPa supply pressure is recommended.
*For unequal pressure installations, 55ºC - 65ºC hot water temperature is recommended.
Contents of Pack
8g x 32 Dome Head
Square Drive
Stainless Steel Screws
Faceplate
Pre-set Mixer Assembly
Temperature
Control Knob
Flow Control
Handle
Allen Key
Mixer Orientation
This mixer is designed to be connected with the hot water supply on the left only and the cold water
supply on the right only.
Top Outlet
HOT Inlet only
COLD Inlet only
Bottom Outlet Option
051012SF
Before Installation
Pipework MUST be purged before connecting to the mixer
Mixer Installation
Ø8 Cut a
0m
m hole
-Ø
85m
m
HO
Ts
No minimum
straight distance
upp
ly o
nly
CO
LD
sup
ply
onl
y
Min 35mm
Max 110mm
Tighten ALL 4 SCREWS on
the inner circle of the faceplate
Ensure that the black felt pen lines on the cartridge
and brass spline are aligned
Seal with silicon
if necessary
Fit the temperature control knob and ensure that
the knob and flow levers are aligned
For technical assistance please ring: 0800 743 358 or (09) 528 0810
Felton Industries Limited
8 Farmhouse Lane, Glen Innes, Auckland 1072 New Zealand
www.felton.co.nz
ADJUSTING MAXIMUM HOT TEMPERATURE LIMIT
This mixer is factory pre-set to a maximum hot temperature of 50°C.
If the pre-set maximum hot temperature is unsuitable for the installation, i.e. too hot or too
cold, adjust the maximum hot temperature limit as below:
1.
Remove grub screw cover and loosen grub screw on temperature control knob, but
leave the temperature control knob on.
2.
Turn the mixer on, set to full hot and test the water temperature.
3.
Carefully slide the temperature control knob approximately 3mm out towards you,
without fully removing it from the spline. This allows the temperature control knob
to be disengaged from the current maximum hot temperature limit stop, and to be
adjustable to your desired maximum hot temperature limit.
4.
Turn the partially removed temperature control knob until desired maximum hot
temperature is achieved. (Turn anti-clockwise to increase maximum hot temperature,
turn clockwise to decrease maximum hot temperature)
5.
Remove handle fully and re-fit it on the splines so that the temperature control
lever is pointing to the very end of the red indicator line (indicating the maximum
hot temperature). The temperature control knob should now be engaged with the
maximum hot temperature limit stop, at your desired maximum hot temperature
limit.
6.
Test the water temperature again.
7.
If the desired maximum hot temperature limit has not been achieved, repeat steps
4 to 6.
8.
Tighten grub screw on temperature control knob and re-fit grub screw cover.
SERVICING CARTRIDGES
To find out where you can purchase a replacement cartridge, please ring Felton on
0800 743 358
1.
Turn off water supply.
2.
Remove grub screw cover and roosen the grub screw beneath the temperature
handle and remove handle.
3.
Remove flow control handle. (see figure A)
4.
Use flow control handle to unscrew the cartridge housing nut as illustrated below.
(see figure B)
5.
Replace cartridge. (see figure C)
6.
Use flow control handle to tighten the cartridge housing nut.
7.
Reverse process for handle assembly.
Figure B.
Figure A.
Figure C.