CC-Link IE - Mitsubishi Electric Australia

Transcription

CC-Link IE - Mitsubishi Electric Australia
2009
Mar
Ethernet-based Open Network
CC-Link IE
Ethernet-based Open Network
Advanced Gigabit Ethernet technology designed
for achieving high speed and large data capacity
CC-Link IE Controller
Network modules
CC-Link IE Controller Network interface boards
On the shop floor, the amount of data that each controller exchanges with other devices or Enterprise information
systems is increasing more than ever. Mitsubishi Electric supports the Gigabit industrial Ethernet open network
to realize these growing demands in manufacturing. CC-Link IE based on Gigabit fiber optic Ethernet medium allows
connection of various devices including 3rd party for achieving the high speed and large data capacity requirements.
Gigabit Ethernet
Standard type With external power
supply function
Reducing costs while improving cycle times
Ethernet topology
● Ethernet topology (IEEE802.3)
Utilizing Ethernet standard cables and connectors
can achieve substantial reduction in costs.
● Multi-mode optical fiber (1000BASE-SX)
● LC connector (IEC61754-20)
Standard type
With external power supply function
*
* A communication unit
for GOT is mounted.
Evolution
More troubleshooting functions for reducing communication time
Visualization of network connection status
High speed data update
Visually displays a whole system's network
connection status such as the error point when a
trouble occurs. Maintenance cost can be reduced.
Performance of cyclic data update of network type
shared memory is enhanced.
Transfer delay time is shortened and application
waiting time also can be reduced.
Large capacity memory
Network type shared memory (cyclic data) with 256K
bytes is realized on one network. Dividing network is
not necessary so that a system that handles a large
capacity data is easily realized.
*1 Values are compared at a network configuration
by 32 modules, with each station's LW2K
points equally allocated, and without disconnected
or reconnected stations.
Large volume
(8 times greater than
conventional networks) *1
Ultra-high speed
(14 times faster than
conventional networks) *1
Enhances the check function of optical fiber
Check function for detecting error points and wrongly
inserted ports of optical fiber cable is enhanced.
Efficient
Error point
Next generation deterministic network designed for the industrial world
Error
No complicated programming involved in configurating a network
Easy data refresh of
network shared memory
Data consistency
guaranteed by station
Using read/write method of
memory, data transmission
is easy.
No need for additional
applications (user program)
to assure consistency
Automatic refresh
between network shared
memory and
programmable controller
device
Sharing data between
controllers is easy because
there is no need to be
conscious of the network.
Stable operation with external power supply input
Supports input of an external power supply to
CC-Link IE Controller Network modules and
interface boards.
Even if the programmable controller CPU or
personal computer is shut down, communication
continues without having to rely on the 'loop back'
function.
External power
supply
External power
supply
Controller Network
External power
supply
1
External power
supply
External power
supply
External power
supply
2
Ethernet-based Open Network CC-Link IE
Ethernet-based Open Network
Application Example : Automotive production line
Its performance lives up to the name,
“IE: Industrial Ethernet”
Basic Specification Comparison
Item
CC-Link IE Controller Network
MELSECNET/H
Communication speed
1 Gbps
25 Mbps
Number of LB points per network
32 K points
16 K points
Number of LW points per network
128 K points
16 K points
Number of stations per network
120 stations
64 stations
Link scan time*
Approx. 5 ms
Approx. 70 ms*2
External power supply connectivity
Available
Available
Interface board connectivity
Available
Available
1
CC-Link IE: High-speed
network reliably carries
huge amounts of data
●Faster
speed: Shorter operation cycle improves
productivity.
●Determinism: Stabilized operation cycle improves
manufacturing quality.
●Large capacity: A large amount of data can be
easily collected from the production equipment.
ALC server
Database server
*1: 32 stations with 2K LW points per station system. Link scan time is calculated value (max. value).
*2: Performance of MELSECNET/H beyond 16 K points is a calculated predicted value.
Large amount of actual performance data
and operation data
Large-capacity data
batch transmission
Ethernet
Provides a high-speed, large-capacity network
through seamless communication across all layers
Network shared memory
(Cyclic data )
Controller Network
● Data sharing
● Data exchange
● Data sharing
● Data exchange
● Data sharing
● Data exchange
● Data sharing
● Data exchange
● Data sharing
● Data exchange
● Data sharing
● Data exchange
Enterprise level network
NEW
Seamless communication
Controller Network
Power train machining
Power train assembly
Stamping
Welding
Painting
Final assembly
Control level network
Device level network
Sensor level network
3
4
Ethernet-based Open Network
Performance Specifications
Item
Specification
Maximum number of
link points per
network
Maximum number of
link points per station
LB
32 K points (32,768 points, 4 KB)
LW
128 K points (131,072 points, 256 KB)
LX
8 K points (8,192 points, 1 KB)
LY
8 K points (8,192 points, 1 KB)
LB
16 K points (16,384 points, 2 KB)
LW
16 K points (16,384 points, 32 KB)
LX
8 K points (8,192 points, 1 KB)
LY
8 K points (8,192 points, 1 KB)
Transmission speed
Group cyclic transmission
Shared group No.1
Control station: No.1
LB0
1 Gbps
Number of stations per network
Connecting cable*1
120 stations max.
Overall length (overall optical cable length)
No.1 send range
No.1
No.1
No.2
No.2 send range
No.2
No.3
No.3
No.3 send range
66 km (when connecting to 120 stations)
550 m max. (core/clad = 50/125 µm)
Duplex LC connector: IEC61754-20 Type LC connector,
insertion loss: 0.3 dB max., polished surface: PC (physical contact) polishing
Connector
Maximum number of networks
Dual loop
Compatible CPU
Universal model QCPU, High Performance model QCPU,
Basic model QCPU*2 NEW , Process CPU NEW , Redundant CPU NEW , Safety CPU*2 NEW
*1: For the recommended cables and other information, contact the CC-Link Partner Association.
*2: For details, refer to the "CC-Link IE Controller Network Reference Manual (SH-080668ENG)".
No.1
No.1
No.4
No.4 send range
No.4
No.5
No.5
No.5 send range
LB7FFF
Product List
Product name
Functions
Item
Description
●Refreshes
link relay/link registers assigned by network common parameters in all stations regularly.
data link registers are guaranteed (data transmission is not divided into 16 bits).
●Communication data consistency is guaranteed by station.
●Group cyclic transmission*3 NEW
●32-bit
●N:N
Transient
transmission
Others
Normal station: No.5
32
Transmission path
Data
communication
functions
Normal station: No.4
239
Maximum number of groups
Cyclic
transmission
Shared group No.2
Normal station: No.3
Link relay (LB)
1000BASE-SX (MMF) fiber optic cable: IEC60793-2-10 Types A1a.1 (50/125 µm multimode),
transmission loss: 3.5 dB/km max. (λ= 850 nm),transmission band: 500 MHz·km min. (λ= 850 nm)
Station-to-station distance
Normal station: No.2
transition (monitor, program upload/download, etc.)
●Various dedicated instructions from the programmable controller program
(READ, SREAD, WRITE, SWRITE, REQ, SEND, RECV, RECVS, ZNRD,
ZNWR, RRUN, RSTOP, RTMRD, and RTMWR).
●Group function (multi-cast communication of transient transmission).
●Routing function (data communication can be established with stations on other network not
directly connected).
●Points for link dedicated instruction: 8192 words NEW
CC-Link IE Controller
Network module
CC-Link IE Controller
Network interface board
CC-Link IE
Controller Network
communication unit
Model
Outline
QJ71GP21-SX
QJ71GP21S-SX
Q80BD-J71GP21-SX
Q80BD-J71GP21S-SX
GT15-J71GP23-SX
NEW
CC-Link IE Controller Network dual loop fiber optic interface module
(1000BASE-SX)For control/normal station
CC-Link IE Controller Network dual loop fiber optic interface module
(1000BASE-SX)For control/normal station, with external power supply function
CC-Link IE Controller Network dual loop fiber optic interface board for PC
(1000BASE-SX) For control/normal station
CC-Link IE Controller Network dual loop fiber optic interface board for PC
(1000BASE-SX) For control/normal station, with external power supply function
CC-Link IE Controller Network dual loop fiber optic communication unit for GOT
(1000BASE-SX) For control/normal station, compatible model: GT15
●Interrupt
program (interruption during data reception from other stations).
between data links (cyclic data is automatically transferred to other networks when
multiple networks exist).
●Transmission
●Off-line
test (H/W test, self-loopback test, etc.)
diagnostics using GX Developer (monitoring network status and status of each station).
●Network diagnostics by SB/SW.
●Control station shifting function (control station substituting function at time of control station failure).
●Loopback function in the event of disconnection and duplexing.
●External power supply function (QJ71GP21S-SX、Q80BD-J71GP21S-SX).
●Improved fiber optic cable integrity monitoring (detecting cable fault and
incorrect cable connection).
●Network
RAS functions
*3: It is a function to share cyclic data with stations in the same shared group. By receiving cyclic data from the stations in the shared
group, the link refresh points are reduced, and the link refresh time is shortened.
(This function can be used when the control station and the station to set the shared group are Universal model QCPU.)
5
6
Ethernet-based Open Network
Interface Board Operating Environment
Description
Item
CPU
Personal
computer
Required memory
PCI bus
specifications
Personal computer with one or more PCI bus slots, or server personal computer with one
or more PCI-X bus slots, which meets the specifications of "Applicable operating system
and required PC performance" shown below.
MEMO
5 V or 3.3 V DC, 32-bit or 64-bit bus, Basic clock: 33 MHz,
supporting PCI bus standard Rev.2.2 or later, supporting PCI-X bus standard 1.0 or later
Resolution: 1024 × 768 dots or higher
Display
80MB or more
Hard disk space
Disk drive
CD-ROM disk drive
Microsoft® Visual Basic® 6.0 (English version),
Microsoft® Visual Basic® .NET 2003 (English version),
Microsoft® Visual Studio 2005 Visual Basic® (English version),
Microsoft® Visual C++® 6.0 (English version),
Microsoft® Visual C++® .NET 2003 (English version), or
Microsoft® Visual Studio 2005 Visual C++® (English version)
Programming language
Applicable operating system and required PC performance
CPU
Operating system
Required memory
Microsoft Windows 2000 Professional (English version)
®
®
256MB or more
Microsoft® Windows® XP Professional (English version)
Microsoft® Windows® XP Home Edition (English version)
Microsoft® Windows® Server 2003 R2 (English version)
PentiumIII® 1GHz or higher
Microsoft® Windows Vista® Home Basic (English version)
Microsoft Windows Vista Home Premium (English version)
®
®
512MB or more
Microsoft® Windows Vista® Business (English version)
Microsoft® Windows Vista® Ultimate (English version)
Microsoft® Windows Vista® Enterprise (English version)
Reference Manual for Interface Board Driver Development
A "reference manual" to develop drivers compatible with various operation systems is provided for customers who intend to use the
CC-Link IE Controller Network interface board in an operation system other than Windows.
This reference manual contains the following information that is required for the driver development.
Hardware information (PCI configuration, dual-port memory, I/O port memory map)
Software information (Initial setting and parameter setting procedures for the driver)
Driver (to be developed)
Application
Sample codes of the C language and their usage (included on the attached CD-ROM)
Various OS
other than Windows
CC-Link IE Controller Network
interface board
Q80BD-J71GP21-SX
* We will introduce entrusted partners for the software development if you wish.
Document (reference manual)
Manual name
CC-Link IE Q80BD-J71GP21-SX
Driver Development
7
Manual number
SH-080819ENG
8
Guide to Partner Products
Ethernet-based Open Network
Cable Accessories
CC-Link IE Controller Network
Compatible Optical Fiber Cable
QG Series
* LCF connector: Double-row LC connector
(IEC61754-20)
Standard Accessories
Protective holder
(One protective holder is enclosed per cable.)
Performance specifications
Cable features
1. This optical fiber cable, recommended by the CC-Link Partner Association, can be used safely
and worry-free.
2. A full lineup of cable is available, including types for use inside panels, indoors, outdoors, and
reinforced type for outdoors, allowing use in various environments.
3. The newly developed thin cable (for indoor and outdoor use) incorporates a cord bundling
structure, allowing safe use even in confined factory cable-laying environments.
4. The indoor use and outdoor use cables are free of tension members, and have an allowable
tension equivalent to the reinforced type for outdoor use.
5. The outdoor use cable is waterproof, and can be used even in flooded or temporary
submerged areas.
6. By attaching the enclosed protective holder (patent pending), breakage at the connector base
can be prevented and space in the panel can be saved.
7. A connector boot, with improved bending characteristics, reduces breakage at the connector
base.
Optional Parts
Relay adaptor
Connector insertion tool
SPAD-LCF-G50
SCT-SLM
Item
Single mode optical fiber cable dedicated port (OPT1 port) Multi-mode optical fiber cable dedicated port (OPT2 port)
Compliant Standards
IEEE802.3z Gigabit Ethernet (1000BASE-LX)
Full duplex method
Transmission method
Applicable optical fiber
IEEE802.3z Gigabit Ethernet (1000BASE-SX)
1.25Gbps
Transmission speed (NRZ)
1000BASE-LX compatible single mode optical fiber cable
1000BASE-SX compatible multi-mode optical fiber cable
(band 500MHz·km or more, λ = 850nm)
Send/receive connectors, one port each (total two ports)
Interface
Applicable connector
Double SC connector (IEC61754-4)*2
Double LC connector (IEC61754-20)
Connector polishing method
PC, SPC, AdPC, UPC polishing
PC polishing
Light projecting center wavelength
1270 to 1360nm
820 to 860nm
Light receiving wavelength
1100 to 1600nm
770 to 860nm
Light projecting level
-3 to -10dBm
-4 to -9.5dBm
Light receiving level
-3 to -20dBm
0 to -17dBm
Allowable light loss
0 to 10dB
0 to 7.5dB
Reference transmission distance
550m (max.)
2m to 15km *
1
*1: Guide when connected to same model. When connecting to a different 1000BASE-LX compatible unit, the distance is 5km.
*2: When connecting with CC-Link IE, the single-end double LC connector and single-end double SC connector optical fiver cable is used.
Power specifications
Item
Rated input voltage
• Protects connector base, and prevents
breakage
• Maintains minimum bending radius
• Saves space in control panel
(60mm or less from front of PLC to end
of protective holder)
Caution:
The protective holder is dedicated for the
Mitsubishi Electric System Service Co.,
Ltd. LCF connector, and is not available
as a single unit. It cannot be mounted on
other LCF connector brands.
Media Converter
Applications:
• Extends optical fiber cable
(relay connection)
• Temporary connection for stations which
may be extended later
Applicable connector:
• LCF connector
(insertion loss: 0.3dB or less *1)
*1: Using master fiber
Application:
• Insertion and removal of connector at
small spaces such as slots on back of
personal computer
Applicable connector:
• LCF/LC/SC/MU connector
DMC-1000SL
100 to 120VAC
1.5A or less
–
Rated input frequency
–
50/60Hz
3.2 to 3.6VDC
90 to 132VAC
Power consumption (DC section)
Apparent power
5.0W or less
–
–
11VA or less
For details of Mitsubishi Electric System & Service Co., Ltd. products,
contact us by sending an e-mail to the following address.
<Sales office> FA PRODUCT DIVISION
mail:[email protected]
From promotion to specification development,
the CLPA supports the spread of CC-Link.
Features
CC-Link IE Controller Network
Compatible Optical Media Converter
AC power rating (AC adaptor)
3.3VDC
Current consumption
Voltage range
Applications:
DC power rating
If the distance between stations is separated by 550m or more (between factory A and C, between
factory B and C), the maximum distance between stations can be extended up to 15km by
inserting two of these products and connecting with single mode optical fiber cables.
CC-Link IE Controller Network communication configuration
CC-Link Partner Association
The Japan-original open field network, CC-Link. CLPA (CC-Link Partner Association), in which Mitsubishi Electric also participates,
was established with a view to spreading CC-Link to the world. Through vigorous activities such as planning and running trade shows
and seminars, conducting conformance tests, and providing information by catalogs, pamphlets, and the Internet, the number of
CLPA partner manufacturers and CC-Link compatible products is increasing steadily, and the CLPA is becoming a driving force for
the globalization of CC-Link.
Conformance tests support the rapid increase of compatible products.
Exhibitions and seminars are held to recruit new partner members.
Multi-mode
optical fiber cable
Max. 550m
Factory A
1000BASE-SX
9
1000BASE-LX conversion
Single mode
optical fiber cable
Max. 15km
Factory C
Factory B
Single mode
optical fiber cable
Max. 15km
This web site provides the latest CC-Link information.
6F Meiji Yasuda Seimei Ozone Bldg., 3-15-58, Ozone, Kita-ku, Nagoya 462-0825, Japan
TEL : +81-52-919-1588 FAX : +81-52-916-8655 URL : http://www.cc-link.org E-mail : [email protected]
10
Ethernet-based Open Network CC-Link IE
This catalog explains the typical features and functions of the MELSEC-Q Series
programmable controllers and CC-Link IE Controller Network modules and does not
provide restrictions and other information on usage and module combinations.
When using the products, always read the user's manuals of the products.
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; opportunity loss or lost profits caused by faults in the Mitsubishi products;
damage, secondary damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to
other duties.
L
(NA)08111E-B 0903
(MDOC)
New publication, effective Mar. 2009
Specifications subject to change without notice.