TUBE LED LIGHTS PARAMETERS AND

Transcription

TUBE LED LIGHTS PARAMETERS AND

co
m
TUBE LED LIGHTS PARAMETERS AND INSTALLATION
INSTRUCTIONS MODEL LL120T8
lot
usL
ED
lig
h
ts.
These
LED
Tubes
can
be
used
as:
1. Replacement
for
T12
and
T8
fluorescent
tubes
–
Retrofit
and
Luminaries
Conversion
2. New
lighting
fixtures
Parameters:
Input
Voltage:
120
VAC,
60
Hz
Power
Consumption:
18
W
Body
temperature:
55
°C
Operating
temperature
range:
‐25
~
+50
°C
Storage
temperature
range:
‐25
~
+60
°C
Power
source:
288
LED
Color
Rendering
Index:
>80
Available
Light
Colors:
Daylight
White
(5,500‐6,000K);
Soft
White
(3,500‐4,000K)
Luminous
Flux:
Daylight
1,200
lm,
Soft
White
1,100
lm
Illumination
at
1m:
380
/
340
lx
Luminous
Efficacy:
>
60
lm/W
Viewing
Angle:
140
°
Lifespan:
50,000
hours
NOT
FOR
USE
WITH
DIMMERS.
NOT
INTENDED
FOR
USE
WITH
EMERGENCY
EXIT
FIXTURES
OR
SIGNS.
lot
usL
ED
lig
h
ts.
co
m
ONLY
PERSON
FAMILIAR
WITH
THE
CONSTRUCTION
AND
OPERATION
OF
THE
PRODUCT
AND
THE
HAZARDS
INVOLVED
MUST
INSTALL
THIS
PRODUCT
IN
ACCORDANCE
WITH
THE
APPLICABLE
INSTALLATION
CODE.
WARNING:
Risk
of
fire
or
electric
shock.
The
electrical
rating
of
this
product
is
120
VAC,
the
installer
must
determine
whether
there
is
120V
at
the
luminaries
before
installation.
WARNING:
Risk
of
fire
or
electric
shock.
Luminaries
wiring,
ballasts,
or
other
electrical
parts
may
be
damaged
when
drilling
for
installation
of
reflector
kit
hardware.
Check
for
enclosed
wiring
and
components.
WARNING:
Risk
of
fire
or
electric
shock.
Reflector
kit
installation
requires
knowledge
of
fluorescent
lighting
luminaries
electrical
systems.
If
not
qualified,
do
not
attempt
installation.
Contact
a
qualified
electrician.
WARNING:
Risk
of
fire
or
electric
shock.
Install
this
kit
only
in
the
luminaries
that
have
the
construction
features
and
dimensions
shown
in
the
photographs
and/or
drawings.
WARNING
‐
To
prevent
wiring
damage
or
abrasion,
do
not
expose
wiring
to
edges
of
sheet
metal
or
other
sharp
objects.
Do
not
make
or
alter
any
open
holes
in
an
enclosure
of
wiring
or
electrical
components
during
kit
installation.
Can
be
used
for
embedded
lights,
maximum
3
tubes
per
fixture.
Not
intended
for
insulation
contact
Recessed
fixture
(NON‐IC
Recessed).
ts.
co
m
Minimum
distance
between
tubes
1/4”
Minimum
distance
between
sockets 3/8”
ED
lig
h
lot
usL
‐These
lamps
work
on
line
voltage
and
require
all
ballasts
and
starters
to
be
removed
before
the
tube
is
installed
in
the
fixture.
‐Only
use
in
NON‐IC
Fluorescent
three
lamped
troffer
style
luminaries.
‐Retrofit
used
with
/
without
lens
luminaries.
‐Use
in
25+/‐5
degree
C
environmental
conditions.
‐Use
in
dry
locations.
‐Do
not
install
in
a
raceway
or
a
luminaries
marked
for
through
branch
wiring.
‐Always
connect
ground
lead
to
fixture
where
applicable.
lot
usL
ED
lig
h
ts.
co
m
INSTALLATLON
INSTRUCTIONS
Step
1
‐
Disconnect
all
power
to
the
lamp
fixture
(figure
1).
Step
2
‐
Remove
the
ballast
and
starter
where
applicable
(figure
2).
Step
3
‐
Designate
one
side
of
the
fixture
lamp
sockets
as
the
“LIVE
END”
and
mark
for
future
reference
(figure
2).
Be
sure
that
the
splices
or
connector
are
insulated
reliably.
lig
h
ts.
co
m
Step
4
‐
For
lamp
holder
where
the
contactors
for
Line
(black)
and
Neutral
(white)
are
connected,
please
take
it
off
and
separate
the
Line
(black)
and
Neutral
(white)
to
disconnect,
and
then
install
it
again.
Step
5
‐
Connect
the
Line
(black)
lead
to
one
of
the
two
wires
connected
to
the
lamp
holder
and
connect
the
Neutral
(white)
lead
to
the
second
of
the
two
wires
connected
to
the
same
lamp
holder
(figure
3).
**For
2
or
3
lamp
fixture,
connect
all
the
Line
(black)
leads
from
each
lamp
holder
to
the
Line
(black)
lead
in
and
connect
all
the
Neutral
(white)
leads
from
each
lamp
holder
to
the
Neutral
(white)
lead
in
(figure
4)**
ED
lot
usL
Step
6
‐
Install
LED
tube
light
in
fixture
matching
the
RED
side
of
the
lamp
to
the
“LIVE
END”
side
of
the
fixture
(figure
5).
Be
sure
that
the
splices
and
connectors
are
insulated
reliably.
www.lotusLEDlights.com