TUBE LED LIGHTS PARAMETERS AND
Transcription
TUBE LED LIGHTS PARAMETERS AND
co m TUBE LED LIGHTS PARAMETERS AND INSTALLATION INSTRUCTIONS MODEL LL120T8 lot usL ED lig h ts. These LED Tubes can be used as: 1. Replacement for T12 and T8 fluorescent tubes – Retrofit and Luminaries Conversion 2. New lighting fixtures Parameters: Input Voltage: 120 VAC, 60 Hz Power Consumption: 18 W Body temperature: 55 °C Operating temperature range: ‐25 ~ +50 °C Storage temperature range: ‐25 ~ +60 °C Power source: 288 LED Color Rendering Index: >80 Available Light Colors: Daylight White (5,500‐6,000K); Soft White (3,500‐4,000K) Luminous Flux: Daylight 1,200 lm, Soft White 1,100 lm Illumination at 1m: 380 / 340 lx Luminous Efficacy: > 60 lm/W Viewing Angle: 140 ° Lifespan: 50,000 hours NOT FOR USE WITH DIMMERS. NOT INTENDED FOR USE WITH EMERGENCY EXIT FIXTURES OR SIGNS. lot usL ED lig h ts. co m ONLY PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED MUST INSTALL THIS PRODUCT IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE. WARNING: Risk of fire or electric shock. The electrical rating of this product is 120 VAC, the installer must determine whether there is 120V at the luminaries before installation. WARNING: Risk of fire or electric shock. Luminaries wiring, ballasts, or other electrical parts may be damaged when drilling for installation of reflector kit hardware. Check for enclosed wiring and components. WARNING: Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaries electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING: Risk of fire or electric shock. Install this kit only in the luminaries that have the construction features and dimensions shown in the photographs and/or drawings. WARNING ‐ To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Can be used for embedded lights, maximum 3 tubes per fixture. Not intended for insulation contact Recessed fixture (NON‐IC Recessed). ts. co m Minimum distance between tubes 1/4” Minimum distance between sockets 3/8” ED lig h lot usL ‐These lamps work on line voltage and require all ballasts and starters to be removed before the tube is installed in the fixture. ‐Only use in NON‐IC Fluorescent three lamped troffer style luminaries. ‐Retrofit used with / without lens luminaries. ‐Use in 25+/‐5 degree C environmental conditions. ‐Use in dry locations. ‐Do not install in a raceway or a luminaries marked for through branch wiring. ‐Always connect ground lead to fixture where applicable. lot usL ED lig h ts. co m INSTALLATLON INSTRUCTIONS Step 1 ‐ Disconnect all power to the lamp fixture (figure 1). Step 2 ‐ Remove the ballast and starter where applicable (figure 2). Step 3 ‐ Designate one side of the fixture lamp sockets as the “LIVE END” and mark for future reference (figure 2). Be sure that the splices or connector are insulated reliably. lig h ts. co m Step 4 ‐ For lamp holder where the contactors for Line (black) and Neutral (white) are connected, please take it off and separate the Line (black) and Neutral (white) to disconnect, and then install it again. Step 5 ‐ Connect the Line (black) lead to one of the two wires connected to the lamp holder and connect the Neutral (white) lead to the second of the two wires connected to the same lamp holder (figure 3). **For 2 or 3 lamp fixture, connect all the Line (black) leads from each lamp holder to the Line (black) lead in and connect all the Neutral (white) leads from each lamp holder to the Neutral (white) lead in (figure 4)** ED lot usL Step 6 ‐ Install LED tube light in fixture matching the RED side of the lamp to the “LIVE END” side of the fixture (figure 5). Be sure that the splices and connectors are insulated reliably. www.lotusLEDlights.com