K-2215T-M LADENA K-99180T

Transcription

K-2215T-M LADENA K-99180T
NOTE: before cutting countertop
Allow for handle clearance
FINISHED WALL / BACK SPLASH
/
70 mm
CENTERLINE OF FITTING
64 mm
K-2215T-M
LADENA
·
·
·
·
·
·
334 mm
·
·
·
·
·
·
·
·
·
K-99180T-RGD
LAUREATE
BEFORE YOU BEGIN
INSTALL THE LAVATORY
· Due to the nature of the installation,
undercounter lavatories should be installed by
trained and experienced installers.
· Do not use adhesives or adhesive sealants with
this product.
· Inspect the waste and supply tubing; replace if
necessary.
· Prior to installation, unpack the new lavatory
and inspect it for damage. Return the lavatory to
its protective carton until you are ready to install
it.
· Observe all local plumbing and building codes.
· Kohler lavatory is made according to American
National Standard that it can match the
American lavatory fittings. Any other lavatory
fittings may not fit for kohler lavatory.
NOTE: Install so future removal from underneath
the countertop is possible to avoid damage to the
countertop.
TOOLS AND MATERIALS
(
13
· Sealant
· Pencil
· Tape measure
· Sharp knife or scissors
· Keyhole or saber saw
· Drill (13mm dia. drill bit or larger)
· Safety glasses
· Hammer
· Rags or paper toweling
NOTE: You may require different, more specialized
tools to install this lavatory to countertop materials
other than wood or wood composites.
)
CL OF FITTING
128
SEALANT
SEALANT
10
29
·
· Check the desired lavatory location for clearance
between the backsplash, faucet, fixture, and
cabinet.
· Cut out the template.
· Carefully position and trace the template on the
countertop as directed on the template.
· Mark the faucet hole centerline on the countertop.
· Drill a 13mm pilot hole on the inside of the cut line.
· Cut out the countertop opening with a saber or
keyhole saw.
·
·
·
·
·
13
FOR WOOD COUNTERTOPS
·
· Mark and pre-drill the wood screw holes at the
locations shown on the template.
· Waterproof any exposed areas of wood.
·
·
Setting Tool
10
Anchor
Marble
16
ó
Foam
Padding
·
Unit: mm
:
· If the countertop has not been installed, install it at
this time.
· Drill the faucet holes according to the faucet
installation instructions.
· Install the faucet to the countertop according to the
manufacturer s instructions.
· Install the drain to the lavatory according to the
manufacturer s instructions.
NOTE: Do not use adhesives or adhesive sealants.
·
·
16
·
409
ó
MARBLE
590
13
279
9.6
HOT
32
OUTLET
9.6
COLD
102 102
38
(S)356
Clamp
25
610
Apply Sealant
·
Screw
864
686
MIN.
203
MIN.
152
MAX.
229
MIN.
·
ADA CLEARANCE
Roughing-In Notes
(ASME)A112.19.2-2008
* K-8998
(T)
·
102
279
ADA DRAIN
OUTLET
25
349
305
25
IMPORTANT CONSUMER
INFORMATION
(CARE AND CLEANING)
·
·
·
0 oC
CLIP LOCATIONS
· To keep your lavatory looking new, make sure
you rinse it out thoroughly after each use. DO
NOT USE ABRASIVES on this product, as
they will scratch and ruin the surface.
Stubborn stains, paint, or tar can be removed
with turpentine or paint thinner.
o
· Do not use the product in the water below 0 C.
· Please do not use hard materials (like
scouring pad) to clean product surface,
especially the product logo.
FOR ARTIST EDITION
PRODUCTS
Treat your decorative product just as you would
treat your fine china. The best way to clean it is to
use warm water and pat dry with a cotton cloth or
soft sponge. DO NOT use bristle brushes or
abrasive-backed sponges. They will scratch the
decorative surface.
SERVICE PARTS
52047
Lav Clamp Accessory
WOOD
INSTALLATION
Note: waterproof unprotected overhang
area on the underside of wood counter.
203
(S) (T)
FOR MARBLE COUNTERTOPS
· Position the countertop upside down on foam
padding to protect the surface. Mark and drill 10mm
holes 16mm deep at the locations shown on the
template.
· Use a setting tool and hammer to secure the
anchors.
FOR ALL INSTALLATIONS
·
ROUGHING-IN
Reference Value
VITREOUS CHINA UNDERCOUNTER LAVATORY
/
CUT-OUT TEMPLATE / INSTALLATION INSTRUCTIONS
Fixture dimensions are nominal and conform to tolerances in ASME Standard A112.19.2-2008.
*Based on K-8998 with 25mm of tailpiece exposed.
(T) Pop-up drain typically 349mm
·
·
(S) 356mm (Based on 305mm riser which may
require cutting.)
·
Supplied basin clamp assemblies require 25mm
minimum countertop thickness. Installer must supply
anchors for thinner countertops.
· Apply a continuous bead of quality sealant to the
lavatory rim where it will contact the countertop.
NOTE: The screws provided should be used on
countertops with a minimum 25mm thickness. For
thinner countertops, use appropriate anchors and
fasteners.
· For wood, wood composite, and marble
countertops, install the lavatory to the countertop
with the clamps and screws provided. For other
countertop materials, refer to the countertop
manufacturer s instructions for recommended
fasteners.
· Position the lavatory squarely under the cutout
before tightening the clamps. Draw the lavatory rim
up to the countertop until it is snug. Do not
overtighten.
· Immediately wipe away any excess sealant.
· Make the final drain and faucet connections to
complete the lavatory installation. Be sure to follow
all instructions packed with the drain and faucet.
· Clean up with a non-abrasive cleaner.
RIM OF LAVATORY
NOTE: Using this template, the
overhung is about 6mm. Customers
can zoom the template by scale to
meet their requirement.
6mm
Kohler reserves the right to change marked dimensions without prior notice.
CUT ALONG THIS LINE
1109626-T01-D
, 2013
ã
ã Copyright Kohler China Ltd., 2013
117215-T01-C
512 mm