Iana 146 Sliding Door

Transcription

Iana 146 Sliding Door
CFI295F
Starting at the bottom, fit the cover strip to the
panel wall channel.
Fit the top caps.
Note:
If the glass is higher
than the wall channel,
trim away the
recessed section
of the top cap.
STEP
25
Lay a thin bead of sealant along the bottom edge,
between the wall and wall channels and between
the panel filler and the glass.
Iana
146 Sliding Door
STEP
26
Fit the door handle.
Do not use the enclosure for
at least 24 hours.
STEP
27
24hrs
STEP
28
Fitting Instructions
The Daryl Care Programme
Keeping your enclosure beautiful throughout its lifetime is easy with
products from the Daryl care programme
Using state of the art bespoke machinery combined with the
latest technology, all Daryl doors and panels are coated with
a glass protector in highly controlled factory conditions.
The protector acts as an invisible barrier on the glass to
prevent build up of limescale, soap scum, stains and dirt.
The factory applied protector will last from months to years
depending on use and the hardness of water in your area.
It will never crack, peel, discolour or build up. Coated
surfaces are kept clean simply by rinsing or wiping with a
damp cloth and regular use of Daryl Glass Cleaner.
There are two separate elements to caring for your Daryl
shower door, enclosure or bath screen.
1 Daryl Glass Cleaner for the regular cleaning of your
shower door, enclosure or screen
2 Daryl Care Kit comprising of Glass Treatment and
Glass Protector suitable for use where glass protector
has not already been applied or for topping up factory
coated protector
Daryl Glass Cleaner
For occasional cleaning of glass treated with Daryl Glass
Protector or for more regular maintenance of untreated
surfaces, we recommend using Daryl Glass Cleaner. The
Cleaner cleans and polishes without smearing or streaking
and rejuvenates the Glass Protector.
Daryl Glass Treatment and Daryl Glass Protector
Available in one care kit, the Treatment and Protector are
used on new or existing shower installations where
Protector has not already been applied and for topping up
factory coated glass after a reasonable length of time. The
Treatment must always be used on existing shower
installations to prepare for the Protector. The Treatment is a
cleaning material that is applied to the glass to ensure it is in
the cleanest condition possible prior to application of the
Protector. If this process is not undertaken, there is the
likelihood of locking in dust, dirt and stains under the
Protector.
Daryl Protector acts as an invisible barrier on the glass to
prevent the build up of lime scale, soap scum, stains and
dirt. Applied like a polish, one application will last from
months to years depending on use and the hardness of
water in your area. It will never crack, peel, discolour or build
up. Coated surfaces are kept clean simply by rinsing or
wiping with a damp cloth and regular use of Daryl Glass
Cleaner.
2 CFI295F
Regular cleaning
IMPORTANT:
Keep the door fully supported at all times.
Move the door until the rollers align with the slot
in the track. Fit the rollers at top and bottom by
pushing them through the slot in the tracks.
Note: The slot in the track is near the wall jamb
at the top and near the inline panel at the bottom.
• Mildew thrives in damp, unventilated areas. It is, therefore,
important to always wipe down, with a soft cloth or towel,
the glass and metal sections inside the shower every time
it is used
Adjuster
• Do not allow water to remain on glass and metal sections
for long periods of time
Adjuster
• In hard water areas, do not allow lime scale to build up.
Stubborn deposits of lime scale can usually be removed
by using a 50:50 solution of vinegar and water, which
should be rinsed off thoroughly and dried after use
Daryl showers trays
Cap
Caution
STEP
21
Everyday Care
Wipe down the glass and metal sections with a soft cloth or
towel and warm water after each time the shower is used.
Do not allow water to remain on glass and metal sections
for long periods, do not allow the build up of lime scale and
do not use caustic cleaners or abrasives.
Cap
Adjust the bottom roller upwards, so it cannot come
out of the slot in the bottom track.
Fit caps after adjustment.
• Every week or two, use Daryl Glass Cleaner to polish the
enclosure (including metal sections) ensuring all surfaces
are wiped down
• Regular cleaning is required to remove the small
amounts of residue that are not repelled by the Protector
Turn the adjusters on the top roller assembly as
required, so the door is level and moves smoothly.
Fit the seal to the edge of the door.
Fit the seal to the closing side wall jamb.
STEP
22
Fit the seals to the end of the inline panel and door.
Glass door
If you have a Daryl shower tray scuffs and marks on acrylic
trays can often be removed by the light use of a mildly
abrasive cleaner applied with a damp cloth and polished off.
Other cleaning materials
Ensure that if you use a non-Daryl cleaning product, it has a
pH level between 4 & 8 and is non-abrasive. Prolonged use
of cleaners with a pH level outside the specified range can
cause damage to metal sections and possibly affect the
safe operation of your Daryl Shower. All cleaning material
(including Daryl’s) must be wiped down after application.
Do not use ‘spray and leave’ cleaning products on the metal
surface as these may cause damage to your door or
enclosure.
Kohler Daryl Limited
Alfred Road, Wallasey, Wirral, CH44 7HY England
Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303
www.daryl-showers.co.uk
E-mail [email protected]
The door seal should fit inside the wall jamb seal
when the door is closed.
The correct position of the seals when the door
is closed.
Glass door
STEP
23
STEP
24
CFI295F
11
Fit the blanking caps to the hole in the door on
both sides. Retain with a small amount of sealant.
Carefully lift the door into position.
Introduction
The following pages aim to provide comprehensive installation instructions, plus
advice on how to care and maintain your product.
We recommend that the unit is installed by a qualified Plumber or Engineer.
Please retain this document for future reference.
Note: Due to our desire to always improve our products, Daryl reserve the right to
change specification without prior notice.
Fit the three edge of glass rollers to the
top casting.
Caution
Safety Precautions
Caution: Care should be taken when drilling into walls and floors to avoid any
hidden pipes or wires.
We strongly recommend that all glass panels are moved by a minimum of two
people and that any protective packaging along the glass edges is kept in place
for as long as possible to prevent damage before installation.
STEP
17
At the bottom the glass fits into the guide.
STEP
14
18
At the inline panel end the roller fits on the top
face of the glass panel.
Wear protective
footwear when
lifting panels
Wear safety
glasses when
drilling
People not familiar with the fitting of Daryl Products may require
the assistance from another person at certain stages of the
procedure. We have indicated these points in the process with
the Caution Symbol.
Caution
Care & Maintenance
STEP
19
10 CFI295F
STEP
20
The unit should be wiped down immediately after each use.
Use a non abrasive cleaner with a pH value between
4 & 8, applied with a soft cloth. A 50:50 solution of
vinegar & water can be used on lime scale deposits,
rinsing off thoroughly after use. Do not use alkalis
such as caustic soda.
Under no circumstances should scourers or
powerful detegents be used as these can damage
the metallic surface of the frame and the surface of
the tray or bath, and also tarnish the glass coating.
If fitted correctly the unit should not require any
maintenance other than cleaning. If problems do
occur contact the Daryl Technical Helpline
Tel: 0151 606 5000
Made in the UK by: Kohler Daryl Limited
Alfred Road, Wallasey, Wirral, CH44 7HY England
Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303
CFI295F
3
Components
Panel Wall
Channel
Check that the panel is far enough into the wall
channel ‘A’ (See Step 7) and the door jamb is far
enough into the wall channel ‘B’ (See Step 9).
Check the inline panel is vertical ‘C’ and the top
track is horizontal ‘D’.
Top Track Assembly
D
A
Inline Panel
Wall Jamb
Measure the distance between the wall channel
and the end of the bottom casting ‘A’.
B
Wall Channel
A
C
A
Cut the panel filler
to the same length
as ‘A’.
Push the filler under the glass.
STEP
14
STEP
13
Lock the panel into the wall channel by turning
the cam through 90o.
Slide the cover on to the adjusters until it locks
in place.
Locked position
On the door side turn the adjusters through
90 to lock the door assembly to the wall channel.
Fit the caps at the bottom.
o
Door
Door Seal
Door Seal
Jamb Door Seal
Unlocked
Door Seal
Cover Strip
Locked
Panel Filler
Bottom Track Assembly
Before installation check that all components are correctly supplied.
If any parts are missing please ring the helpline. Tel: 0151 606 5000
4
CFI295F
STEP
15
STEP
16
CFI295F
9
Remove the adjusters from the top track, and
door guide assembly from the bottom track
(keep the screws).
Carefully lift the door
assembly into place.
Support the top
and bottom tracks
at all times.
Top Caps
Top Cover
Caution
Cap
Cap
x2
x2
Door Handle
Assembly
The line on the wall
channel marks the
maximum amount of
adjustment.
When fitted this line
MUST NOT be visible
outside the wall jamb.
STEP
9
Attach the the panel to the tracks at the
top and bottom.
Roller
x3
STEP
10
C
Door
Adjuster
Cap
Refit the adjusters and temporarily secure the
top track to the inline panel.
B
x2
x4
x3
A
x6
Spacer
Turn
adjusters
until the
glass is parallel
with the casting.
x6
x2
(1 not required)
4mm Allen Key
Refit the door guide assembly and gasket at
the bottom.
Plug
x4
Adjustment Range
1000mm unit
1200mm unit
1400mm unit
STEP
11
8 CFI295F
STEP
12
?
3mm Allen Key
938 to 996mm
1138 to 1196mm
1338 to 1396mm
44 (0)151 606 5000
CFI295F
5
Fit tray and then tile walls before
fitting the unit.
NOTE: The version shown is a ‘LH panel,
RH door’. Fitting a ‘RH panel, LH door’
is a mirror image of these instructions.
DOOR SIDE
Mark wall 11mm in
from edge of tray.
x3
Carefully lift the inline panel into place,
uncoated side to the outside.
Break the spacer in half.
DOOR SIDE: Fit the door wall channel to the wall.
x3
6mm
x3
11m
6mm
m
3mm
Place both sections into the base of the
panel wall channel.
x3
Caution
Wall channel
MUST be
vertical on
the front face.
A
11m
m
±0mm
IMPORTANT
Tray MUST be level in all
planes or the unit will not
install properly.
STEP
1
PANEL SIDE: Fit the panel wall channel to the wall.
PANEL SIDE
x3
Note:
Fixing block must
be on the inside
edge of the wall
channel.
x3
6mm
Mark wall 22mm in
from edge of tray.
STEP
5
STEP
2
Carefully slide the panel into the wall channel.
Engage the mouldings but do not lock into
place at this moment.
Door Side:
Fit the plugs to the holes at the end of the tracks.
Fit the top and bottom tracks to the wall jamb.
Once fitted ensure structure is supported at all times.
Top
x3
m
22m
Wall channel
MUST be
vertical on
front face.
STEP
6
Caution
Note:
Assembly is
aided by
tilting the
panel and
moving the
fixing blocks
up or down
in the wall
channel.
IMPORTANT:
The flat section
of track should
face upwards
at the top and
face down at
the bottom.
Plugs
Bottom
A
22mm
Smaller screw
30mm Max
C
Angled section
faces the inside
of the enclosure.
STEP
3
6 CFI295F
STEP
4
STEP
7
B
B
STEP
8
CFI295F
7